{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T11:13:45Z","timestamp":1791976425503,"version":"4.4.0"},"reference-count":19,"publisher":"Oxford University Press (OUP)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,9,1]]},"DOI":"10.1093\/icvts\/ivu176","type":"journal-article","created":{"date-parts":[[2014,6,3]],"date-time":"2014-06-03T23:13:41Z","timestamp":1401837221000},"page":"448-455","source":"Crossref","is-referenced-by-count":29,"title":["Usefulness of vessel-sealing devices for \u22647 mm diameter vessels: a randomized controlled trial for human thoracoscopic lobectomy in primary lung cancer"],"prefix":"10.1093","volume":"19","author":[{"given":"Masayuki","family":"Toishi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuo","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Agatsuma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takao","family":"Sakaizawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Eguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaku","family":"Saito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Hashizume","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazutoshi","family":"Hamanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takayuki","family":"Shiina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2014,6,3]]},"reference":[{"key":"key\n\t\t\t\t20180106074247_IVU176C1","doi-asserted-by":"crossref","first-page":"2553","DOI":"10.1200\/JCO.2008.18.2733","article-title":"Systemic review and meta-analysis of randomized and nonrandomized trials on safety and efficacy of video-assisted thoracic surgery lobectomy for early-stage non-small-cell lung cancer","volume":"27","author":"Yan","year":"2009","journal-title":"J Clin Oncol"},{"key":"key\n\t\t\t\t20180106074247_IVU176C2","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1016\/j.jtcvs.2011.09.028","article-title":"Video-assisted thoracoscopic surgery (VATS) lobectomy: catastrophic intraoperative complications","volume":"14","author":"Flores","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C3","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1002\/hed.22932","article-title":"Initial experience using a bipolar radiofrequency ablation device for hemostasis during thyroidectomy","volume":"35","author":"Baldwin","year":"2013","journal-title":"Head Neck"},{"key":"key\n\t\t\t\t20180106074247_IVU176C4","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.breast.2012.08.003","article-title":"Axillary lymphadenectomy for breast cancer. A randomized controlled trial comparing a bipolar vessel sealing system to the conventional technique","volume":"21","author":"Nespoli","year":"2012","journal-title":"Breast"},{"key":"key\n\t\t\t\t20180106074247_IVU176C5","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1002\/bjs.7679","article-title":"Randomized clinical trial comparing the cost and effectiveness of bipolar vessel sealers versus clips and vascular staplers for laparoscopic colorectal resection","volume":"98","author":"Adamina","year":"2011","journal-title":"Br J Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C6","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1016\/j.jtcvs.2010.06.064","article-title":"Preliminary results of anatomic lung resection using energy-based tissue and vessel coagulative fusion technology","volume":"140","author":"Schuchert","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C7","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1510\/icvts.2010.239087","article-title":"Electrothermal bipolar vessel sealing device LigaSureV for pulmonary artery ligation\u2014burst pressure and clinical experiences in complete video-assisted thoracoscopic major lung resection for lung cancer","volume":"11","author":"Tsunezuka","year":"2010","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C8","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1510\/icvts.2008.199307","article-title":"Comparing bipolar electrothermal device and endostapler in endoscopic lung wedge resection","volume":"9","author":"Kov\u00e1cs","year":"2009","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C9","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1510\/icvts.2008.200584","article-title":"Clinical application of an ultrasonic scalpel to divide pulmonary vessels based on laboratory evidence","volume":"8","author":"Tanaka","year":"2009","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C10","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1016\/j.jtcvs.2012.11.009","article-title":"Sealing of pulmonary arteries with LigaSure: in vivo and ex vivo examinations","volume":"145","author":"Lesser","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C11","article-title":"Feasibility of using a vessel sealing system in a human pulmonary lobectomy: a retrospective comparison of this procedure with or without a vessel sealing system","author":"Yoshida","year":"2013","journal-title":"Ann Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C12","doi-asserted-by":"crossref","first-page":"S48","DOI":"10.1016\/j.jtcvs.2012.06.001","article-title":"Use of energy-based coagulative fusion technology and lung sealants during anatomic lung resection","volume":"144","author":"Schuchert","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C13","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1007\/s00464-007-9619-8","article-title":"Comparison of four energy-based vascular sealing and cutting instruments: a porcine model","volume":"22","author":"Person","year":"2008","journal-title":"Surg Endosc"},{"key":"key\n\t\t\t\t20180106074247_IVU176C14","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.ejcts.2005.11.017","article-title":"Use of an electrothermal bipolar tissue sealing system in lung surgery","volume":"29","author":"Santini","year":"2006","journal-title":"Eur J Cardiothorac Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C15","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1007\/s004640080025","article-title":"Initial results with an electrothermal bipolar vessel sealer","volume":"15","author":"Heniford","year":"2001","journal-title":"Surg Endosc"},{"key":"key\n\t\t\t\t20180106074247_IVU176C16","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1053\/j.semtcvs.2012.03.002","article-title":"Thoracoscopic mediastinal lymph node dissection for lung cancer","volume":"24","author":"Watanabe","year":"2012","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C17","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1093\/ejcts\/ezt445","article-title":"Results of Li-Tho trial: a prospective randomized study on effectiveness of LigaSure(R) in lung resections","volume":"45","author":"Bertolaccini","year":"2014","journal-title":"Eur J Cardiothorac Surg"},{"key":"key\n\t\t\t\t20180106074247_IVU176C18","doi-asserted-by":"crossref","first-page":"2892","DOI":"10.1007\/s00464-012-2276-6","article-title":"Effectiveness of electrothermal bipolar vessel-sealing devices versus other electrothermal and ultrasonic devices for abdominal surgical hemostasis: a systematic review","volume":"26","author":"Janssen","year":"2012","journal-title":"Surg Endosc"},{"key":"key\n\t\t\t\t20180106074247_IVU176C19","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.jmig.2013.04.014","article-title":"Laparoscopic supracervical hysterectomy using EnSeal vs standard bipolar coagulation technique: randomized controlled trial","volume":"20","author":"Rothmund","year":"2013","journal-title":"J Minim Invasive Gynecol"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/icvts\/article-pdf\/19\/3\/448\/23298691\/ivu176.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,1,6]],"date-time":"2018-01-06T07:43:04Z","timestamp":1515224584000},"score":1,"resource":{"primary":{"URL":"http:\/\/academic.oup.com\/icvts\/article\/19\/3\/448\/2859497"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,3]]},"references-count":19,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2014,6,3]]},"published-print":{"date-parts":[[2014,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivu176","relation":{},"ISSN":["1569-9293","1569-9285"],"issn-type":[{"value":"1569-9293","type":"print"},{"value":"1569-9285","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,6,3]]}}}