{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,12,8]],"date-time":"2023-12-08T10:19:34Z","timestamp":1702030774786},"reference-count":4,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2019,5,6]],"date-time":"2019-05-06T00:00:00Z","timestamp":1557100800000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Cardiac resynchronization therapy-defibrillator device upgrades may represent a challenging scenario, especially because unexpected findings can increase procedure difficulty. One such unexpected finding represents insulation failure with unremarkable device interrogation. Insulation failure due to an externalized conductor of an implantable cardiac defibrillator-lead has been recently described for the Kentrox lead (Biotronik). Another challenging aspect of device upgrades is the presence of venous thrombosis as in this case. Here, we report an inside-out abrasion of a Kentrox lead, an unexpected second insulation failure found during pocket revision and the successful recanalization in a patient with known left subclavian vein thrombosis.<\/jats:p>","DOI":"10.1093\/icvts\/ivz101","type":"journal-article","created":{"date-parts":[[2019,3,22]],"date-time":"2019-03-22T16:15:30Z","timestamp":1553271330000},"page":"484-486","source":"Crossref","is-referenced-by-count":1,"title":["Externalized conductor of a Kentrox lead and an unexpected insulation failure"],"prefix":"10.1093","volume":"29","author":[{"given":"Jaime-J\u00fcrgen","family":"Eulert-Grehn","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany"},{"name":"DZHK (German Center for Cardiovascular Research), partner site Berlin, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Volkmar","family":"Falk","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany"},{"name":"DZHK (German Center for Cardiovascular Research), partner site Berlin, Berlin, Germany"},{"name":"Department of Cardiothoracic Surgery, Charit\u00e9-Universit\u00e4tsmedizin Berlin, Freie Universit\u00e4t Berlin, Humboldt-Universit\u00e4t zu Berlin, Berlin Institute of Health, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mir Timo","family":"Nazari-Shafti","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany"},{"name":"DZHK (German Center for Cardiovascular Research), partner site Berlin, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Starck","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany"},{"name":"DZHK (German Center for Cardiovascular Research), partner site Berlin, Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,5,5]]},"reference":[{"key":"2019091012164928400_ivz101-B1","doi-asserted-by":"crossref","first-page":"1648","DOI":"10.1016\/j.hrthm.2014.05.012","article-title":"Conductor externalization of the Biotronik Kentrox internal cardioverter-defibrillator lead: the tip of another iceberg?","volume":"11","author":"Abi-Saleh","year":"2014","journal-title":"Heart Rhythm"},{"key":"2019091012164928400_ivz101-B2","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1111\/jce.12562","article-title":"Insulation failure and externalized conductor of a single-coil Kentrox lead: an ongoing story?","volume":"26","author":"Bogossian","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2019091012164928400_ivz101-B3","doi-asserted-by":"crossref","first-page":"27","DOI":"10.12998\/wjcc.v5.i2.27","article-title":"Externalized conductors and insulation failure in Biotronik defibrillator leads: history repeating or a false alarm?","volume":"5","author":"De Maria","year":"2017","journal-title":"World J Clin Cases"},{"key":"2019091012164928400_ivz101-B4","first-page":"1358","article-title":"Implantable cardiac defibrillator lead failure and management","volume-title":"J Am Coll Cardiol","author":"Swerdlow","year":"2016"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/icvts\/advance-article-pdf\/doi\/10.1093\/icvts\/ivz101\/28560884\/ivz101.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/icvts\/article-pdf\/29\/3\/484\/29217669\/ivz101.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,10]],"date-time":"2019-09-10T13:16:49Z","timestamp":1568121409000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/29\/3\/484\/5485840"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,5]]},"references-count":4,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2019,5,5]]},"published-print":{"date-parts":[[2019,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivz101","relation":{},"ISSN":["1569-9285"],"issn-type":[{"value":"1569-9285","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,9]]},"published":{"date-parts":[[2019,5,5]]}}}