{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T07:04:24Z","timestamp":1779519864024,"version":"3.53.1"},"reference-count":29,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,23]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The concentrations of some drugs in biofluids can be affected by different storage conditions, including the type of sample collection tube. This phenomenon has been observed in gel separation tubes, where drug adsorption to the gel separator can lead to the underestimation of the drugs concentration, thus potentially affecting the interpretation of analytical results. The purpose of this study was to determine if concentrations of tetrahydrocannabinol (THC), its metabolites, and related cannabinoids decrease over time when stored in plasma separation tubes (PSTs) as compared to non-PSTs. Plasma samples with a high concentration [HP\u201424\u2009ng\/mL THC, 150\u2009ng\/mL carboxy-THC (THC-COOH), 48\u2009ng\/mL hydroxy-THC (THC-OH), 15\u2009ng\/mL cannabidiol (CBD), and 15\u2009ng\/mL cannabinol (CBN)], and low concentration [LP\u20145.0\u2009ng\/mL THC, 31\u2009ng\/mL THC-COOH, 10\u2009ng\/mL THC-OH, 3.1\u2009ng\/mL CBD, and 3.1\u2009ng\/mL CBN] of cannabinoids were stored in PSTs and non-PSTs for analysis by liquid chromatography\u2014tandem mass spectrometry at one-hour, three-day, one-week, two-week, three-week, one-month, two-month, and three-month intervals. Statistically significant differences in cannabinoid concentrations (p\u2009&amp;lt;\u2009.05) were observed between non-PSTs and PSTs. All cannabinoids except THC-COOH showed a greater reduction in concentration when stored in PSTs compared to non-PSTs. In contrast, THC-COOH showed an increase in concentration when stored in PSTs compared to non-PSTs. Over a three-month period, concentrations in PSTs decreased for THC by 83% and 81%, THC-OH by 66% and 63%, CBD by 69% and 62%, and CBN by 75% and 70% in LP and HP samples, respectively. In conclusion, for forensic cases involving cannabinoids, the adsorption of these compounds should be considered in the toxicological interpretation of samples collected in PSTs.<\/jats:p>","DOI":"10.1093\/jat\/bkag001","type":"journal-article","created":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T12:32:12Z","timestamp":1767702732000},"source":"Crossref","is-referenced-by-count":0,"title":["Adsorption of Tetrahydrocannabinol, Metabolites, and Related Cannabinoids During Storage of Plasma Samples in Gel Separation Tubes"],"prefix":"10.1093","volume":"50","author":[{"given":"Idris A","family":"Abdul","sequence":"first","affiliation":[{"name":"University of Toronto Institute of Forensic Sciences, , Toronto, ON L5L1C6,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9880-5979","authenticated-orcid":false,"given":"Dale","family":"Pon","sequence":"additional","affiliation":[{"name":"Centre of Forensic Sciences Toxicology Section, , 25 Morton Shulman Ave , Toronto, ON M3M0B1,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chesia","family":"Giancola","sequence":"additional","affiliation":[{"name":"Centre of Forensic Sciences Laboratory Services Section, , 25 Morton Shulman Ave , Toronto, ON M3M0B1,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5101-3352","authenticated-orcid":false,"given":"Karen","family":"Woodall","sequence":"additional","affiliation":[{"name":"University of Toronto Institute of Forensic Sciences, , Toronto, ON L5L1C6,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,1,6]]},"reference":[{"key":"2026052302060718100_bkag001-B1","author":"BD Vacutainer gel tubes FAQs"},{"key":"2026052302060718100_bkag001-B2","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1515\/CCLM.2006.099","article-title":"Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use","volume":"44","author":"O\u2019Keane","year":"2006","journal-title":"Clin Chem Lab Med"},{"key":"2026052302060718100_bkag001-B3","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/s0009-8981(01)00396-5","article-title":"Comparison of BD Vacutainer SSTTM Plus Tubes with BD SSTTM II Plus Tubes for common analytes","volume":"306","author":"Bush","year":"2001","journal-title":"Clin Chim Acta"},{"key":"2026052302060718100_bkag001-B4","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1097\/FTD.0000000000000592","article-title":"Substantial differences in serum concentrations of psychoactive drugs measured in samples stored for 2 days or more on standard serum tubes versus serum tubes containing gel separators","volume":"41","author":"Wollmann","year":"2019","journal-title":"Ther Drug Monit"},{"key":"2026052302060718100_bkag001-B5","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1097\/00007691-199606000-00016","article-title":"Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes","volume":"18","author":"Dasgupta","year":"1996","journal-title":"Ther Drug Monit"},{"key":"2026052302060718100_bkag001-B6","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1097\/FTD.0000000000000708","article-title":"Stability of 21 antihypertensive drugs in serum collected in standard (nongel) serum tubes versus tubes containing a gel separator","volume":"42","author":"Hegstad","year":"2020","journal-title":"Ther Drug Monit"},{"key":"2026052302060718100_bkag001-B7","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1097\/00007691-200008000-00011","article-title":"Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube","volume":"22","author":"Dasgupta","year":"2000","journal-title":"Ther Drug Monit"},{"key":"2026052302060718100_bkag001-B8","doi-asserted-by":"publisher","first-page":"1505","DOI":"10.1007\/s00216-007-1267-2","article-title":"Stability of analytes in biosamples\u2014an important issue in clinical and forensic toxicology?","volume":"388","author":"Peters","year":"2007","journal-title":"Anal Bioanal Chem"},{"key":"2026052302060718100_bkag001-B9","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1097\/00007691-200106000-00013","article-title":"Stability of therapeutic drugs in serum collected in Vacutainer serum separator tubes containing a new gel (SST II)","volume":"23","author":"Bush","year":"2001","journal-title":"Ther Drug Monit"},{"key":"2026052302060718100_bkag001-B10","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.clinbiochem.2022.08.009","article-title":"Evaluation of serum and rapid serum separator collection tubes for therapeutic drug assays","volume":"115","author":"Garza","year":"2023","journal-title":"Clin Biochem"},{"key":"2026052302060718100_bkag001-B11","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.cca.2018.10.043","article-title":"The right blood collection tube for therapeutic drug monitoring and toxicology screening procedures: Standard tubes, gel or mechanical separator?","volume":"488","author":"Schrapp","year":"2019","journal-title":"Clin Chim Acta"},{"key":"2026052302060718100_bkag001-B12","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1093\/jat\/bkab118","article-title":"Adsorption of therapeutic and recreational drugs during prolonged storage of plasma samples in gel separator tubes","volume":"46","author":"Shepard","year":"2023","journal-title":"J Anal Toxicol"},{"key":"2026052302060718100_bkag001-B13","author":"Report on Drug Per Se Limits","year":"2017"},{"key":"2026052302060718100_bkag001-B14","author":"Drug Per Se Laws","year":"2019"},{"key":"2026052302060718100_bkag001-B15","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.cca.2016.08.014","article-title":"Where clinical chemistry meets medicinal chemistry. Systematic analysis of physico-chemical properties predicts stability of common used drugs in gel separator serum tubes","volume":"462","author":"Steuer","year":"2016","journal-title":"Clin Chim Acta"},{"key":"2026052302060718100_bkag001-B16","doi-asserted-by":"publisher","first-page":"801","DOI":"10.3390\/metabo12090801","article-title":"Effects of the storage conditions on the stability of natural and synthetic cannabis in biological matrices for forensic toxicology analysis: an update from the literature","volume":"12","author":"Djilali","year":"2022","journal-title":"Metabolites"},{"key":"2026052302060718100_bkag001-B17","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1093\/jat\/8.5.202","article-title":"Stability of 9-tetrahydrocannabinol (THC), 11-hydroxy-THC, and 11-nor-9-carboxy-THC in blood and plasma","volume":"8","author":"Johnson","year":"1984","journal-title":"J Anal Toxicol"},{"key":"2026052302060718100_bkag001-B18","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.forsciint.2012.11.006","article-title":"Recovery of spiked \u03949-tetrahydrocannabinol in oral fluid from polypropylene containers","volume":"227","author":"Molnar","year":"2013","journal-title":"Forensic Sci Int"},{"key":"2026052302060718100_bkag001-B19","doi-asserted-by":"publisher","first-page":"1108","DOI":"10.1373\/clinchem.2012.201467","article-title":"In vitro stability of free and glucuronidated cannabinoids in blood and plasma following controlled smoked cannabis","volume":"59","author":"Scheidweiler","year":"2013","journal-title":"Clin Chem"},{"key":"2026052302060718100_bkag001-B20","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1093\/jat\/10.4.129","article-title":"Tetrahydrocannabinol stability in whole blood: plastic versus glass containers","volume":"10","author":"Christophersen","year":"1986","journal-title":"J Anal Toxicol"},{"key":"2026052302060718100_bkag001-B21","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s11419-015-0290-9","article-title":"In vitro stability of free and glucuronidated cannabinoids in blood and plasma collected in plastic gray-top sodium fluoride tubes following controlled smoked cannabis","volume":"34","author":"Scheidweiler","year":"2016","journal-title":"Forensic Toxicol"},{"key":"2026052302060718100_bkag001-B22","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1093\/jat\/bkt054","article-title":"Standard practices for method validation in forensic toxicology","volume":"37","author":"Scientific Working Group for Forensic Toxicology (SWGTOX)","year":"2013","journal-title":"J Anal Toxicol"},{"key":"2026052302060718100_bkag001-B23","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1093\/ajcp\/101.4.456","article-title":"Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes: volume- and time-dependent reduction in total and free drug concentrations","volume":"101","author":"Dasgupta","year":"1994","journal-title":"Am J Clin Pathol"},{"key":"2026052302060718100_bkag001-B24","doi-asserted-by":"publisher","first-page":"327","DOI":"10.2165\/00003088-200342040-0000312648025","article-title":"Pharmacokinetics and pharmacodynamics of cannabinoids","volume":"42","author":"Grotenhermen","year":"2003","journal-title":"Clin Pharmacokinet"},{"key":"2026052302060718100_bkag001-B25","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1093\/jat\/25.5.339","article-title":"Importance of vacutainer selection in forensic toxicological analysis of drugs of abuse","volume":"25","author":"Toennes","year":"2001","journal-title":"J Anal Toxicol"},{"key":"2026052302060718100_bkag001-B26","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1093\/clinchem\/48.2.301","article-title":"Stability of 11-nor-\u03949-carboxy-tetrahydrocannabinol glucuronide in plasma and urine assessed by liquid chromatography-tandem mass spectrometry","volume":"48","author":"Skopp","year":"2002","journal-title":"Clin Chem"},{"key":"2026052302060718100_bkag001-B27","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1373\/clinchem.2011.171777","article-title":"Identification of recent cannabis use: whole-blood and plasma free and glucuronidated cannabinoid pharmacokinetics following controlled smoked cannabis administration","volume":"57","author":"Schwope","year":"2011","journal-title":"Clin Chem"},{"key":"2026052302060718100_bkag001-B28","doi-asserted-by":"publisher","first-page":"e157","DOI":"10.1093\/labmed\/lmad022","article-title":"Heparin concentration in evacuated tubes and its efect on pH, ionized calcium, lactate, and potassium in venous blood gas analysis","volume":"54","author":"Mahler","year":"2023","journal-title":"Lab Med"},{"key":"2026052302060718100_bkag001-B29","volume-title":"StatPearls","author":"Bayot","year":"2023"}],"container-title":["Journal of Analytical Toxicology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jat\/advance-article-pdf\/doi\/10.1093\/jat\/bkag001\/66286598\/bkag001.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jat\/article-pdf\/50\/4\/bkag001\/66286598\/bkag001.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jat\/article-pdf\/50\/4\/bkag001\/66286598\/bkag001.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T06:06:15Z","timestamp":1779516375000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jat\/article\/doi\/10.1093\/jat\/bkag001\/8415997"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,6]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,5,23]]}},"URL":"https:\/\/doi.org\/10.1093\/jat\/bkag001","relation":{},"ISSN":["0146-4760","1945-2403"],"issn-type":[{"value":"0146-4760","type":"print"},{"value":"1945-2403","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,4]]},"published":{"date-parts":[[2026,1,6]]},"article-number":"bkag001"}}