{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T06:31:33Z","timestamp":1781591493182,"version":"3.54.5"},"reference-count":39,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2024,1,17]],"date-time":"2024-01-17T00:00:00Z","timestamp":1705449600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Patients with severe burns are at high risk of thermoregulatory failure. Yet, there is a lack of consensus regarding the optimum approach to temperature dysregulation in patients with severe burns. Intravascular temperature management catheters may offer a superior method of temperature control, but robust data are lacking. In this article, we describe our experience in using a thermoregulatory catheter for temperature management in a tertiary referral burns center. We conducted a single-center, prospective evaluation of the use of a thermoregulatory intravenous catheter system (Thermogard XP\u00ae) in critically injured burns patients admitted to our intensive care unit over an 18-month period. Ten patients had a total of 12 catheters inserted. Patient temperatures were maintained between a median low of 36.9 \u00b0C and a median high of 38.4 \u00b0C while in the intensive care unit. If patients were transferred to theater, the median temperature change was \u22120.15 \u00b0C (interquartile range [IQR] \u22120.3, 0) if TBSA was \u226450% and \u22121.45 \u00b0C (IQR \u22122.05, \u22120.975) if &amp;gt;50%. No surgical procedures were terminated due to intraoperative hypothermia. On return from theater, 72.2% of patients were normothermic with a median temperature of 36.8 \u00b0C. Thirty percent of patients developed a thrombotic complication. Overall, the device appeared reliable in achieving and maintaining normothermia for critically ill burns patients manifesting temperature dysregulation. It may also be of benefit to patients expected to show temperature fluctuations during operative procedures. Further research is needed to define whether this represents an improvement over current practice and investigate the thrombus risk associated with such devices.<\/jats:p>","DOI":"10.1093\/jbcr\/irae006","type":"journal-article","created":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T13:43:10Z","timestamp":1705585390000},"page":"978-984","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of a thermoregulatory intravascular catheter in critically ill burns patients"],"prefix":"10.1093","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-7793-2858","authenticated-orcid":false,"given":"Amy","family":"Brown","sequence":"first","affiliation":[{"name":"Glasgow Royal Infirmary , Glasgow G4 0SF , UK"},{"name":"NHS Greater Glasgow and Clyde , Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1587-1242","authenticated-orcid":false,"given":"Christopher","family":"McGovern","sequence":"additional","affiliation":[{"name":"Glasgow Royal Infirmary , Glasgow G4 0SF , UK"},{"name":"NHS Greater Glasgow and Clyde , Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie","family":"Davidson","sequence":"additional","affiliation":[{"name":"Glasgow Royal Infirmary , Glasgow G4 0SF , UK"},{"name":"NHS Greater Glasgow and Clyde , Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachael","family":"Boyle","sequence":"additional","affiliation":[{"name":"Glasgow Royal Infirmary , Glasgow G4 0SF , UK"},{"name":"NHS Greater Glasgow and Clyde , Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5167-2171","authenticated-orcid":false,"given":"Derek David Truong","family":"Farnham","sequence":"additional","affiliation":[{"name":"Glasgow Royal Infirmary , Glasgow G4 0SF , UK"},{"name":"NHS Greater Glasgow and Clyde , Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lia","family":"Paton","sequence":"additional","affiliation":[{"name":"Glasgow Royal Infirmary , Glasgow G4 0SF , UK"},{"name":"NHS Greater Glasgow and Clyde , Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,1,17]]},"reference":[{"key":"2024080703325620500_CIT0001","first-page":"1895","article-title":"Early hypothermia as risk factor in severely burned patients: a retrospective outcome study","volume-title":"Burns","author":"Ziegler","year":"2019"},{"key":"2024080703325620500_CIT0002","first-page":"101","article-title":"Emergency pre-hospital care of burn patients","volume-title":"Surgeon","author":"Muehlberger","year":"2010"},{"key":"2024080703325620500_CIT0003","first-page":"226","article-title":"Temperature management of adult burn patients in intensive care: findings from a retrospective cohort study in a tertiary centre in the United Kingdom","volume-title":"Anaesthesiol Intensive Ther","author":"Driver","year":"2022"},{"key":"2024080703325620500_CIT0004","first-page":"e277","article-title":"Perioperative temperature management during burn care","volume-title":"J Burn Care Res","author":"Rizzo","year":"2017"},{"key":"2024080703325620500_CIT0005","first-page":"326","article-title":"Recovery from postoperative hypothermia predicts survival in extensively burned patients","volume-title":"Am J Surg","author":"Shiozaki","year":"1993"},{"key":"2024080703325620500_CIT0006","first-page":"1673","article-title":"The impact of operative time and hypothermia in acute burn surgery","volume-title":"Burns","author":"Ziolkowski","year":"2017"},{"key":"2024080703325620500_CIT0007","first-page":"39","article-title":"Hypothermia in acutely presenting burn injuries to a regional burn service: the incidence and impact on outcome","volume-title":"Burns Open","author":"Lukusa","year":"2021"},{"key":"2024080703325620500_CIT0008","first-page":"456","article-title":"The association between hypothermia, prehospital cooling, and mortality in burn victims","volume-title":"Acad Emerg Med","author":"Singer","year":"2010"},{"key":"2024080703325620500_CIT0009","first-page":"11","article-title":"Burn injury","volume-title":"Nat Rev Dis Primers","author":"Jeschke","year":"2020"},{"key":"2024080703325620500_CIT0010","first-page":"100709","article-title":"Current problems in burn hypermetabolism","volume-title":"Curr Probl Surg","author":"Sommerhalder","year":"2020"},{"key":"2024080703325620500_CIT0011","first-page":"576","article-title":"Pathophysiological response to burn injury in adults","volume-title":"Ann Surg","author":"Stanojcic","year":"2018"},{"key":"2024080703325620500_CIT0012","first-page":"1857","article-title":"Metabolic implications of severe burn injuries and their management: a systematic review of the literature","volume-title":"World J Surg","author":"Atiyeh","year":"2008"},{"key":"2024080703325620500_CIT0013","first-page":"541","article-title":"Metabolic and endocrine considerations after burn injury","volume-title":"Clin Plast Surg","author":"Williams","year":"2017"},{"key":"2024080703325620500_CIT0014","first-page":"1417","article-title":"The metabolic stress response to burn trauma: current understanding and therapies","volume-title":"Lancet (London, England)","author":"Porter","year":"2016"},{"key":"2024080703325620500_CIT0015","first-page":"387","article-title":"Pathophysiologic response to severe burn injury","volume-title":"Ann Surg","author":"Jeschke","year":"2008"},{"key":"2024080703325620500_CIT0016","first-page":"252","article-title":"Cellular effects of hyperthermia: relevance to the minimum dose for thermal damage","volume-title":"Int J Hyperth","author":"Lepock","year":"2003"},{"key":"2024080703325620500_CIT0017","first-page":"3","article-title":"Cellular responses to hyperthermia (40\u201346 \u00b0 C): cell killing and molecular events","volume-title":"Int J Hyperth","author":"Roti Roti","year":"2008"},{"key":"2024080703325620500_CIT0018","first-page":"953","article-title":"ISBI practice guidelines for burn care","volume-title":"Burns","author":"Ahuja","year":"2016"},{"key":"2024080703325620500_CIT0019","first-page":"1978","article-title":"Heat stroke","volume-title":"N Engl J Med","author":"Bouchama","year":"2002"},{"issue":"3","key":"2024080703325620500_CIT0020","first-page":"136","article-title":"A descriptive survey of operating theatre and intensive care unit temperature management of burn patients in the United Kingdom","volume":"11","author":"Mullhi","year":"2021","journal-title":"Int J Burns Trauma"},{"key":"2024080703325620500_CIT0021","first-page":"612","article-title":"A survey of temperature management practices among Burn Centers in North America","volume-title":"J Burn Care Res","author":"Pruskowski","year":"2018"},{"key":"2024080703325620500_CIT0022","first-page":"485","article-title":"Control of the hypermetabolic response to burn injury using environmental factors","volume-title":"Ann Surg","author":"Caldwell","year":"1992"},{"key":"2024080703325620500_CIT0023","first-page":"1859","article-title":"The impact of ambient temperature control across various care settings on outcomes in burn patients: a review article","volume-title":"Am Surg","author":"Kinter","year":"2021"},{"key":"2024080703325620500_CIT0024","first-page":"285","article-title":"Effect of different methods of cooling for targeted temperature management on outcome after cardiac arrest: a systematic review and meta-analysis","volume-title":"Crit Care","author":"Calabr\u00f3","year":"2019"},{"key":"2024080703325620500_CIT0025","first-page":"82","article-title":"Systematic review and meta-analysis of intravascular temperature management vs surface cooling in comatose patients resuscitated from cardiac arrest","volume-title":"Resuscitation","author":"Bartlett","year":"2020"},{"key":"2024080703325620500_CIT0026","first-page":"61","article-title":"Intravascular versus surface cooling for targeted temperature management after out-of-hospital cardiac arrest: an analysis of the TTH48 trial","volume-title":"Crit Care","author":"de Fazio","year":"2019"},{"key":"2024080703325620500_CIT0027","first-page":"648","article-title":"Maintenance of normothermia during burn surgery with an intravascular temperature control system: a non-randomised controlled trial","volume-title":"Injury","author":"Prunet","year":"2012"},{"key":"2024080703325620500_CIT0028","first-page":"A15","article-title":"Hypothermia in burns intensive care: use of the intravenous temperature management system Thermogard XP\u00ae","volume-title":"Crit Care","author":"Nachiappan","year":"2012"},{"key":"2024080703325620500_CIT0029","first-page":"141","article-title":"A novel method to treat hyperthermia in a burns case: use of a catheter-based heat exchange system","volume-title":"Burns","author":"Mavrogordato","year":"2009"},{"key":"2024080703325620500_CIT0030","first-page":"h2988","article-title":"PAin SoluTions In the Emergency Setting (PASTIES)\u2014patient controlled analgesia versus routine care in emergency department patients with pain from traumatic injuries: randomised trial","volume-title":"BMJ","author":"Smith","year":"2015"},{"key":"2024080703325620500_CIT0031","author":"Zoll Medical Corporation","year":"2020"},{"key":"2024080703325620500_CIT0032","first-page":"71","article-title":"Thermoregulatory central venous catheter-associated thrombus\u2014echocardiographic detection and novel approach to management","volume-title":"J Intensive Care Soc","author":"Gillon","year":"2015"},{"key":"2024080703325620500_CIT0033","first-page":"261","article-title":"Association between intravascular thermoregulation devices and the development of venous thrombo-embolic phenomenon","volume-title":"J Intensive Care Soc","author":"Winder-Rhodes","year":"2017"},{"key":"2024080703325620500_CIT0034","first-page":"100","article-title":"Thermoregulatory catheter-associated inferior vena cava thrombus","volume-title":"Bayl Univ Med Center Proc","author":"Gierman","year":"2013"},{"issue":"5","key":"2024080703325620500_CIT0035","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1177\/000313480707300508","article-title":"Increased risk of deep venous thrombosis with endovascular cooling in patients with traumatic head injury","volume":"73","author":"Simosa","year":"2007","journal-title":"Am Surg"},{"key":"2024080703325620500_CIT0036","first-page":"245","article-title":"A warning for warming catheters: interventional radiology\u2019s role","volume-title":"Diagn Interv Radiol","author":"Moriarty","year":"2020"},{"key":"2024080703325620500_CIT0037","first-page":"80","article-title":"Venous thromboembolism in severe burns patients with intravascular warming catheter: a retrospective cohort study","volume-title":"Eur Burn J","author":"Reid","year":"2023"},{"issue":"7","key":"2024080703325620500_CIT0038","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1016\/j.burns.2023.05.003","article-title":"Surviving sepsis after burn campaign","volume":"49","author":"Greenhalgh","year":"2023","journal-title":"Burns"},{"key":"2024080703325620500_CIT0039","volume-title":"Rev 6 ICY\u00ae Intravascular","author":"Zoll Medical Corporation","year":"2022"}],"container-title":["Journal of Burn Care &amp; Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jbcr\/advance-article-pdf\/doi\/10.1093\/jbcr\/irae006\/56534092\/irae006.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbcr\/article-pdf\/45\/4\/978\/58749320\/irae006.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbcr\/article-pdf\/45\/4\/978\/58749320\/irae006.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T04:46:10Z","timestamp":1723005970000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbcr\/article\/45\/4\/978\/7571228"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,17]]},"references-count":39,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,1,17]]},"published-print":{"date-parts":[[2024,8,6]]}},"URL":"https:\/\/doi.org\/10.1093\/jbcr\/irae006","relation":{},"ISSN":["1559-047X","1559-0488"],"issn-type":[{"value":"1559-047X","type":"print"},{"value":"1559-0488","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,7]]},"published":{"date-parts":[[2024,1,17]]}}}