{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T11:45:06Z","timestamp":1783338306771,"version":"3.54.6"},"reference-count":82,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2023,5,13]],"date-time":"2023-05-13T00:00:00Z","timestamp":1683936000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,9,22]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Breast MRI is a highly sensitive imaging modality that often detects findings that are occult on mammography and US. Given the overlap in appearance of benign and malignant lesions, an accurate method of tissue sampling for MRI-detected findings is essential. Although MRI-directed US and correlation with mammography can be helpful for some lesions, a correlate is not always found. MRI-guided biopsy is a safe and effective method of tissue sampling for findings seen only on MRI. The unique limitations of this technique, however, contribute to false negatives, which can result in delays in diagnosis and adverse patient outcomes; this is of particular importance as most MRI examinations are performed in the high-risk or preoperative setting. Here, we review strategies to minimize false negatives in biopsy of suspicious MRI findings, including appropriate selection of biopsy modality, use of meticulous MRI-guided biopsy technique, management after target nonvisualization, assessment of adequate lesion sampling, and determination of radiology-pathology concordance. A proposed management algorithm for MRI-guided biopsy results will also be discussed.<\/jats:p>","DOI":"10.1093\/jbi\/wbad024","type":"journal-article","created":{"date-parts":[[2023,5,13]],"date-time":"2023-05-13T23:03:27Z","timestamp":1684019007000},"page":"597-610","source":"Crossref","is-referenced-by-count":4,"title":["Reducing False Negatives in Biopsy of Suspicious MRI Findings"],"prefix":"10.1093","volume":"5","author":[{"given":"Lilian C","family":"Wang","sequence":"first","affiliation":[{"name":"Northwestern Medicine, Department of Radiology , Chicago, IL , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Rao","sequence":"additional","affiliation":[{"name":"Northwestern Medicine, Department of Radiology , Chicago, IL , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Schacht","sequence":"additional","affiliation":[{"name":"Northwestern Medicine, Department of Radiology , Chicago, IL , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonya","family":"Bhole","sequence":"additional","affiliation":[{"name":"Northwestern Medicine, Department of Radiology , Chicago, IL , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,5,13]]},"reference":[{"key":"2023092301562341700_CIT0001","author":"American College of Radiology"},{"issue":"5","key":"2023092301562341700_CIT0002","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1002\/cncr.21720","article-title":"Magnetic resonance-guided, vacuum-assisted breast biopsy: results from a European multicenter study of 538 lesions","volume":"106","author":"Perlet","year":"2006","journal-title":"Cancer"},{"issue":"1","key":"2023092301562341700_CIT0003","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1007\/s00330-013-2989-5","article-title":"MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques","volume":"24","author":"Imschweiler","year":"2014","journal-title":"Eur Radiol"},{"issue":"7","key":"2023092301562341700_CIT0004","doi-asserted-by":"crossref","first-page":"4886","DOI":"10.1007\/s00330-020-07392-6","article-title":"Long-term MRI-guided vacuum-assisted breast biopsy results of 600 single-center procedures","volume":"31","author":"Lambert","year":"2021","journal-title":"Eur Radiol"},{"issue":"2","key":"2023092301562341700_CIT0005","doi-asserted-by":"crossref","first-page":"292","DOI":"10.2214\/AJR.11.7594","article-title":"Outcome analysis of 9-gauge MRI-guided vacuum-assisted core needle breast biopsies","volume":"198","author":"Rauch","year":"2012","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0006","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1148\/radiol.2381050050","article-title":"MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: initial experience","volume":"238","author":"Orel","year":"2006","journal-title":"Radiology"},{"issue":"3","key":"2023092301562341700_CIT0007","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1097\/RLI.0000000000000331","article-title":"Safety and efficacy of magnetic resonance-guided vacuum-assisted large-volume breast biopsy (MR-guided VALB)","volume":"52","author":"Schrading","year":"2017","journal-title":"Invest Radiol"},{"issue":"1","key":"2023092301562341700_CIT0008","doi-asserted-by":"crossref","first-page":"W17","DOI":"10.2214\/AJR.16.16404","article-title":"Radiologic-pathologic discordance and outcome after MRI-guided vacuum-assisted biopsy","volume":"208","author":"Lewin","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"8","key":"2023092301562341700_CIT0009","doi-asserted-by":"crossref","first-page":"2510","DOI":"10.1007\/s00330-015-4071-y","article-title":"Breast MR biopsy: pathological and radiological correlation","volume":"26","author":"Dratwa","year":"2016","journal-title":"Eur Radiol"},{"issue":"7","key":"2023092301562341700_CIT0010","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1016\/j.crad.2014.02.003","article-title":"MR imaging-guided vacuum-assisted breast biopsy: reduction of false-negative biopsies by short-term control MRI 24-48 h after biopsy","volume":"69","author":"Bahrs","year":"2014","journal-title":"Clin Radiol"},{"issue":"1","key":"2023092301562341700_CIT0011","doi-asserted-by":"crossref","first-page":"183","DOI":"10.2214\/ajr.185.1.01850183","article-title":"MRI-guided 9-gauge vacuum-assisted breast biopsy: initial clinical experience","volume":"185","author":"Liberman","year":"2005","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0012","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1007\/s00330-007-0704-0","article-title":"MR-guided vacuum-assisted breast biopsy with a handheld biopsy system: clinical experience and results in postinterventional MR mammography after 24 h","volume":"18","author":"Hauth","year":"2008","journal-title":"Eur Radiol"},{"issue":"11","key":"2023092301562341700_CIT0013","doi-asserted-by":"crossref","first-page":"3908","DOI":"10.1007\/s00330-016-4267-9","article-title":"MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience","volume":"26","author":"Spick","year":"2016","journal-title":"Eur Radiol"},{"issue":"2","key":"2023092301562341700_CIT0014","doi-asserted-by":"crossref","first-page":"341","DOI":"10.2214\/AJR.08.1127","article-title":"False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1,280 lesions and review of the literature","volume":"192","author":"Jackman","year":"2009","journal-title":"AJR Am J Roentgenol"},{"issue":"8","key":"2023092301562341700_CIT0015","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.acra.2016.03.023","article-title":"Frequency of discordant lesions and false-negative cancers at stereotactic vacuum-assisted biopsy","volume":"23","author":"Heller","year":"2016","journal-title":"Acad Radiol"},{"issue":"10","key":"2023092301562341700_CIT0016","doi-asserted-by":"crossref","first-page":"2613","DOI":"10.1016\/j.ejrad.2011.10.027","article-title":"Stereotactic core biopsy: comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy","volume":"81","author":"Venkataraman","year":"2012","journal-title":"Eur J Radiol"},{"issue":"12","key":"2023092301562341700_CIT0017","doi-asserted-by":"crossref","first-page":"2538","DOI":"10.1002\/1097-0142(20001215)89:12<2538::AID-CNCR4>3.0.CO;2-#","article-title":"Imaging-histologic discordance at percutaneous breast biopsy","volume":"89","author":"Liberman","year":"2000","journal-title":"Cancer"},{"issue":"2","key":"2023092301562341700_CIT0018","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1148\/radiol.2482071994","article-title":"US-guided 14-gauge core-needle breast biopsy: results of a validation study in 1352 cases","volume":"248","author":"Schueller","year":"2008","journal-title":"Radiology"},{"issue":"1","key":"2023092301562341700_CIT0019","doi-asserted-by":"crossref","first-page":"55","DOI":"10.14366\/usg.17028","article-title":"Ultrasonography-guided 14-gauge core biopsy of the breast: results of 7 years of experience","volume":"37","author":"Jung","year":"2018","journal-title":"Ultrasonography"},{"issue":"3","key":"2023092301562341700_CIT0020","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1102\/1470-7330.2012.0047","article-title":"The negative predictive value of ultrasound-guided 14-gauge core needle biopsy of breast masses: a validation study of 339 cases","volume":"12","author":"Zhang","year":"2012","journal-title":"Cancer Imaging"},{"issue":"1","key":"2023092301562341700_CIT0021","doi-asserted-by":"crossref","first-page":"202","DOI":"10.2214\/AJR.07.2419","article-title":"Sonographically guided 14-gauge core needle biopsy of breast masses: a review of 2,420 cases with long-term follow-up","volume":"190","author":"Youk","year":"2008","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2023092301562341700_CIT0022","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1148\/radiol.14140474","article-title":"Diagnostic utility of second-look US for breast lesions identified at MR imaging: systematic review and meta-analysis","volume":"273","author":"Spick","year":"2014","journal-title":"Radiology"},{"issue":"3","key":"2023092301562341700_CIT0023","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1093\/jbi\/wbac020","article-title":"Bleeding complications after breast core-needle biopsy\u2014an approach to managing patients on antithrombotic therapy","volume":"4","author":"Goudreau","year":"2022","journal-title":"Journal of Breast Imaging"},{"issue":"2","key":"2023092301562341700_CIT0024","doi-asserted-by":"crossref","first-page":"E46","DOI":"10.1148\/rg.210126","article-title":"MRI-guided breast biopsy case-based review: essential techniques and approaches to challenging cases","volume":"42","author":"Adrada","year":"2022","journal-title":"Radiographics"},{"issue":"2 Pt A","key":"2023092301562341700_CIT0025","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jacr.2021.10.023","article-title":"Reducing number of patient visits and time to biopsy after suspicious breast MRI","volume":"19","author":"Rahman","year":"2022","journal-title":"J Am Coll Radiol"},{"issue":"11","key":"2023092301562341700_CIT0026","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.7863\/jum.2002.21.11.1221","article-title":"Preferential use of sonographically guided biopsy to minimize patient discomfort and procedure time in a percutaneous image-guided breast biopsy program","volume":"21","author":"Mainiero","year":"2002","journal-title":"J Ultrasound Med"},{"issue":"3","key":"2023092301562341700_CIT0027","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1148\/radiology.208.3.9722851","article-title":"US-guided core breast biopsy: use and cost-effectiveness","volume":"208","author":"Liberman","year":"1998","journal-title":"Radiology"},{"issue":"4","key":"2023092301562341700_CIT0028","doi-asserted-by":"crossref","first-page":"927","DOI":"10.2214\/AJR.17.18489","article-title":"Sonographic-MRI correlation after percutaneous sampling of targeted breast ultrasound lesions: initial experiences with limited-sequence unenhanced MRI for postprocedural clip localization","volume":"210","author":"Lee","year":"2018","journal-title":"AJR Am J Roentgenol"},{"issue":"12","key":"2023092301562341700_CIT0029","doi-asserted-by":"crossref","first-page":"5196","DOI":"10.1007\/s00330-017-4924-7","article-title":"Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI","volume":"27","author":"Song","year":"2017","journal-title":"Eur Radiol"},{"issue":"4","key":"2023092301562341700_CIT0030","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.2214\/AJR.09.2480","article-title":"Targeted ultrasound of the breast in women with abnormal MRI findings for whom biopsy has been recommended","volume":"193","author":"Meissnitzer","year":"2009","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2023092301562341700_CIT0031","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.crad.2019.10.013","article-title":"Accuracy of MRI-directed ultrasound and subsequent ultrasound-guided biopsy for suspicious breast MRI findings","volume":"75","author":"Chikarmane","year":"2020","journal-title":"Clin Radiol"},{"issue":"3","key":"2023092301562341700_CIT0032","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1002\/jmri.25738","article-title":"MRI-guided breast interventions","volume":"46","author":"McGrath","year":"2017","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2023092301562341700_CIT0033","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1053\/j.tvir.2013.12.007","article-title":"Breast magnetic resonance imaging for the interventionalist: magnetic resonance imaging-guided vacuum-assisted breast biopsy","volume":"17","author":"Brennan","year":"2014","journal-title":"Tech Vasc Interv Radiol"},{"issue":"3","key":"2023092301562341700_CIT0034","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1148\/radiol.2016151947","article-title":"Underestimation rate at MR imaging-guided vacuum-assisted breast biopsy: a multi-institutional retrospective study of 1509 breast biopsies","volume":"281","author":"Verheyden","year":"2016","journal-title":"Radiology"},{"issue":"4","key":"2023092301562341700_CIT0035","doi-asserted-by":"crossref","first-page":"916","DOI":"10.2214\/AJR.16.16576","article-title":"Imaging-concordant benign MRI-guided vacuum-assisted breast biopsy may not warrant MRI follow-up","volume":"208","author":"Huang","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2023092301562341700_CIT0036","doi-asserted-by":"crossref","first-page":"850","DOI":"10.2214\/AJR.08.2226","article-title":"MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy","volume":"193","author":"Li","year":"2009","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0037","doi-asserted-by":"crossref","first-page":"223","DOI":"10.2214\/AJR.12.10228","article-title":"Patient outcomes in canceled MRI-guided breast biopsies","volume":"202","author":"Niell","year":"2014","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2023092301562341700_CIT0038","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1007\/s00330-002-1713-7","article-title":"Follow-up of breast lesions detected by MRI not biopsied due to absent enhancement of contrast medium","volume":"13","author":"Hefler","year":"2003","journal-title":"Eur Radiol"},{"issue":"9","key":"2023092301562341700_CIT0039","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/j.acra.2018.01.016","article-title":"Canceled MRI-guided breast biopsies due to nonvisualization: follow-up and outcomes","volume":"25","author":"Pinnamaneni","year":"2018","journal-title":"Acad Radiol"},{"issue":"1","key":"2023092301562341700_CIT0040","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1148\/radiol.11100720","article-title":"Cancellation of MR imaging-guided breast biopsy due to lesion nonvisualization: frequency and follow-up","volume":"261","author":"Brennan","year":"2011","journal-title":"Radiology"},{"issue":"1","key":"2023092301562341700_CIT0041","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1148\/radiol.14131384","article-title":"The effects of applying breast compression in dynamic contrast material-enhanced MR imaging","volume":"272","author":"El Khouli","year":"2014","journal-title":"Radiology"},{"issue":"5","key":"2023092301562341700_CIT0042","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.acra.2013.01.005","article-title":"Cancelation of MRI guided breast biopsies for suspicious breast lesions identified at 3.0 T MRI: reasons, rates, and outcomes","volume":"20","author":"Johnson","year":"2013","journal-title":"Acad Radiol"},{"key":"2023092301562341700_CIT0043","author":"American College of Radiology"},{"issue":"6","key":"2023092301562341700_CIT0044","doi-asserted-by":"crossref","first-page":"1176","DOI":"10.1007\/s00330-014-3125-x","article-title":"Short interval follow-up after a benign concordant MR-guided vacuum assisted breast biopsy\u2014is it worthwhile","volume":"24","author":"Shaylor","year":"2014","journal-title":"Eur Radiol"},{"issue":"1","key":"2023092301562341700_CIT0045","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1093\/jbi\/wbaa089","article-title":"Compliance with short-interval follow-up MRI after benign concordant MRI-guided breast biopsy","volume":"3","author":"Ram","year":"2020","journal-title":"J Breast Imag"},{"issue":"6","key":"2023092301562341700_CIT0046","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.2214\/AJR.12.10282","article-title":"Why are patients noncompliant with follow-up recommendations after MRI-guided core needle biopsy of suspicious breast lesions","volume":"201","author":"Thompson","year":"2013","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"2023092301562341700_CIT0047","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1016\/j.clinimag.2016.06.005","article-title":"Follow-up outcomes after benign concordant MRI-guided breast biopsy","volume":"40","author":"Hayward","year":"2016","journal-title":"Clin Imaging"},{"issue":"4","key":"2023092301562341700_CIT0048","doi-asserted-by":"crossref","first-page":"852","DOI":"10.2214\/AJR.07.2531","article-title":"Imaging histologic discordance at MRI-guided 9-gauge vacuum-assisted breast biopsy","volume":"189","author":"Lee","year":"2007","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"2023092301562341700_CIT0049","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.2214\/AJR.11.7455","article-title":"Patient follow-up after concordant histologically benign imaging-guided biopsy of MRI-detected lesions","volume":"198","author":"Sung","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"2023092301562341700_CIT0050","volume-title":"ACR BI-RADS\n              \u00ae\n            Atlas, Breast Imaging Reporting and Data System","author":"D\u2019Orsi","year":"2013"},{"key":"2023092301562341700_CIT0051","article-title":"ACR BI-RADS\u00ae Magnetic Resonance Imaging","volume-title":"ACR BI-RADS\u00aeAtlas, Breast Imaging Reporting and Data System","author":"Morris","year":"2013"},{"issue":"6","key":"2023092301562341700_CIT0052","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.2214\/AJR.16.16730","article-title":"Utility of BI-RADS assessment category 4 subdivisions for screening breast MRI","volume":"208","author":"Strigel","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0053","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1148\/radiol.12110619","article-title":"Positive predictive value of BI-RADS MR imaging","volume":"264","author":"Mahoney","year":"2012","journal-title":"Radiology"},{"issue":"1","key":"2023092301562341700_CIT0054","doi-asserted-by":"crossref","first-page":"171","DOI":"10.2214\/ajr.179.1.1790171","article-title":"Breast lesions detected on MR imaging: features and positive predictive value","volume":"179","author":"Liberman","year":"2002","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"2023092301562341700_CIT0055","doi-asserted-by":"crossref","first-page":"994","DOI":"10.2214\/AJR.08.1983","article-title":"BI-RADS lesion characteristics predict likelihood of malignancy in breast MRI for masses but not for nonmasslike enhancement","volume":"193","author":"Gutierrez","year":"2009","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0056","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1148\/radiol.2381042117","article-title":"Diagnostic architectural and dynamic features at breast MR imaging: multicenter study","volume":"238","author":"Schnall","year":"2006","journal-title":"Radiology"},{"issue":"2","key":"2023092301562341700_CIT0057","doi-asserted-by":"crossref","first-page":"442","DOI":"10.2214\/AJR.16.17048","article-title":"Radiologic-pathologic correlation for benign results after MRI-guided breast biopsy","volume":"209","author":"Maglione","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2023092301562341700_CIT0058","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.carj.2015.07.003","article-title":"Improving patient care by incorporation of multidisciplinary breast radiology-pathology correlation conference","volume":"67","author":"Prakash","year":"2016","journal-title":"Can Assoc Radiol J"},{"key":"2023092301562341700_CIT0059","doi-asserted-by":"crossref","first-page":"151864","DOI":"10.1016\/j.anndiagpath.2021.151864","article-title":"Impact of multidisciplinary radiologic-pathologic correlation conference for benign image-guided breast biopsies on discordance rates and patient outcomes in a community teaching hospital","volume":"57","author":"Olayinka","year":"2022","journal-title":"Ann Diagn Pathol"},{"issue":"5","key":"2023092301562341700_CIT0060","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1097\/01.sla.0000186186.05971.e0","article-title":"The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases","volume":"242","author":"Dillon","year":"2005","journal-title":"Ann Surg"},{"issue":"September\u2013October","key":"2023092301562341700_CIT0061","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.clinimag.2019.05.007","article-title":"Do benign-concordant breast MRI biopsy results require short interval follow-up imaging? Report of longitudinal study and review of the literature","volume":"57","author":"Pinkney","year":"2019","journal-title":"Clin Imaging"},{"issue":"9","key":"2023092301562341700_CIT0062","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.jacr.2014.02.003","article-title":"Auditing a breast MRI practice: performance measures for screening and diagnostic breast MRI","volume":"11","author":"Niell","year":"2014","journal-title":"J Am Coll Radiol"},{"issue":"6","key":"2023092301562341700_CIT0063","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.2214\/AJR.07.2827","article-title":"Outcome of MRI-guided breast biopsy","volume":"191","author":"Han","year":"2008","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0064","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.ejrad.2005.09.004","article-title":"MR-guided intervention in women with a family history of breast cancer","volume":"57","author":"Viehweg","year":"2006","journal-title":"Eur J Radiol"},{"issue":"3","key":"2023092301562341700_CIT0065","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1007\/s10549-021-06251-2","article-title":"Unveiling the histopathologic spectrum of MRI-guided breast biopsies: an institutional pathological-radiological correlation","volume":"187","author":"Moreno","year":"2021","journal-title":"Breast Cancer Res Treat"},{"issue":"8","key":"2023092301562341700_CIT0066","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1007\/s00330-011-2094-6","article-title":"Probability of malignancy for lesions detected on breast MRI: a predictive model incorporating BI-RADS imaging features and patient characteristics","volume":"21","author":"Demartini","year":"2011","journal-title":"Eur Radiol"},{"issue":"4","key":"2023092301562341700_CIT0067","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.acra.2016.10.014","article-title":"Screening breast MRI outcomes in routine clinical practice: comparison to BI-RADS benchmarks","volume":"24","author":"Strigel","year":"2017","journal-title":"Acad Radiol"},{"issue":"2","key":"2023092301562341700_CIT0068","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/AJR.13.11553","article-title":"Importance of a personal history of breast cancer as a risk factor for the development of subsequent breast cancer: results from screening breast MRI","volume":"202","author":"Schacht","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"2023092301562341700_CIT0069","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.breast.2016.06.007","article-title":"Radial scars diagnosed on breast core biopsy: frequency of atypia and carcinoma on excision and implications for management","volume":"30","author":"Donaldson","year":"2016","journal-title":"Breast"},{"key":"2023092301562341700_CIT0070","author":"American Society of Breast Surgeons"},{"issue":"3","key":"2023092301562341700_CIT0071","doi-asserted-by":"crossref","first-page":"684","DOI":"10.2214\/AJR.06.0809","article-title":"Underestimation of atypical ductal hyperplasia at MRI-guided 9-gauge vacuum-assisted breast biopsy","volume":"188","author":"Liberman","year":"2007","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2023092301562341700_CIT0072","doi-asserted-by":"crossref","first-page":"792","DOI":"10.2214\/AJR.09.4081","article-title":"Frequency, upgrade rates, and characteristics of high-risk lesions initially identified with breast MRI","volume":"195","author":"Strigel","year":"2010","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2023092301562341700_CIT0073","doi-asserted-by":"crossref","first-page":"237","DOI":"10.2214\/AJR.13.10600","article-title":"Outcome of high-risk lesions at MRI-guided 9-gauge vacuum-assisted breast biopsy","volume":"202","author":"Heller","year":"2014","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2023092301562341700_CIT0074","doi-asserted-by":"crossref","first-page":"249","DOI":"10.2214\/AJR.11.7610","article-title":"Imaging features and management of high-risk lesions on contrast-enhanced dynamic breast MRI","volume":"198","author":"Heller","year":"2012","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2023092301562341700_CIT0075","doi-asserted-by":"crossref","first-page":"622","DOI":"10.2214\/AJR.20.23040","article-title":"High-risk lesions detected by MRI-guided core biopsy: upgrade rates at surgical excision and implications for management","volume":"216","author":"Michaels","year":"2021","journal-title":"AJR Am J Roentgenol"},{"issue":"1090","key":"2023092301562341700_CIT0076","doi-asserted-by":"crossref","first-page":"20180300","DOI":"10.1259\/bjr.20180300","article-title":"High risk breast lesions identified on MRI-guided vacuum-assisted needle biopsy: outcome of surgical excision and imaging follow-up","volume":"91","author":"Speer","year":"2018","journal-title":"Br J Radiol"},{"issue":"3","key":"2023092301562341700_CIT0077","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1007\/s12282-019-01032-8","article-title":"High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: imaging characteristics, outcome of surgical excision or imaging follow-up","volume":"27","author":"Okamoto","year":"2020","journal-title":"Breast Cancer"},{"issue":"3","key":"2023092301562341700_CIT0078","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s10549-022-06761-7","article-title":"High-risk lesions in the breast diagnosed by MRI-guided core biopsy: upgrade rates and features associated with malignancy","volume":"196","author":"Cha","year":"2022","journal-title":"Breast Cancer Res Treat"},{"issue":"2","key":"2023092301562341700_CIT0079","doi-asserted-by":"crossref","first-page":"W132","DOI":"10.2214\/AJR.11.7799","article-title":"Multidisciplinary considerations in the management of high-risk breast lesions","volume":"198","author":"Krishnamurthy","year":"2012","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2023092301562341700_CIT0080","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/s10549-020-05977-9","article-title":"Management of high-risk breast lesions diagnosed on core biopsies and experiences from prospective high-risk breast lesion conferences at an academic institution","volume":"185","author":"Li","year":"2021","journal-title":"Breast Cancer Res Treat"},{"issue":"6","key":"2023092301562341700_CIT0081","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1111\/tbj.12500","article-title":"The management of benign concordant MRI-guided breast biopsies: lessons learned","volume":"21","author":"Lee","year":"2015","journal-title":"Breast J"},{"issue":"1","key":"2023092301562341700_CIT0082","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1093\/jbi\/wbaa089","article-title":"Compliance with short-interval follow-up MRI after benign concordant MRI-guided breast biopsy","volume":"3","author":"Ram","year":"2021","journal-title":"J Breast Imag"}],"container-title":["Journal of Breast Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jbi\/article-pdf\/5\/5\/597\/51727276\/wbad024.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbi\/article-pdf\/5\/5\/597\/51727276\/wbad024.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T01:56:49Z","timestamp":1695434209000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbi\/article\/5\/5\/597\/7161798"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,13]]},"references-count":82,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023,5,13]]},"published-print":{"date-parts":[[2023,9,22]]}},"URL":"https:\/\/doi.org\/10.1093\/jbi\/wbad024","relation":{},"ISSN":["2631-6110","2631-6129"],"issn-type":[{"value":"2631-6110","type":"print"},{"value":"2631-6129","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,9,1]]},"published":{"date-parts":[[2023,5,13]]}}}