{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:24:38Z","timestamp":1787009078693,"version":"build-2736575974"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2024,9,8]],"date-time":"2024-09-08T00:00:00Z","timestamp":1725753600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the frequency and factors associated with clip migration in MRI-guided breast biopsies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This study was approved by our Institutional Review Board and was compliant with HIPAA. We retrospectively evaluated all MRI-guided biopsies performed between January 2013 and December 2020 in our institution for clip migration. Only patients with follow-up breast MRI showing the clip were included in the study. Migration was defined as movement of the clip of 10 mm or more from the target lesion. Migration frequency and directions were recorded. Factors associated with clip migration were analyzed using statistical tests as appropriate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 291 biopsies in 268 women were included in the study with 31 migration events recorded (11%; 95% CI, 7%-15%). All migrations occurred along the biopsy tract; 97% (30\/31) of them displaced distal to the needle entry site. More than 50% regional fat (around the target lesion) was the strongest factor associated with migration, seen in 21\/141 women (15%), compared to 10\/150 (7%) with 50% or less local fat (P\u2009=\u2009.023). Global fatty breast was more loosely associated with migration, showing borderline significance (P\u2009=\u2009.06). Other factors did not correlate with clip migration, including lesion size, depth, or location; pathology result; breast thickness; or biopsy approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Although clip migration after breast MRI-guided biopsy is an uncommon event, it occurs more often when the target lesion is surrounded by fat, with the clip usually displaced away from the needle entry site.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/jbi\/wbae049","type":"journal-article","created":{"date-parts":[[2024,7,26]],"date-time":"2024-07-26T18:32:32Z","timestamp":1722018752000},"page":"621-627","source":"Crossref","is-referenced-by-count":1,"title":["Beyond the Needle: Understanding Tissue Marker Migration in Breast MRI-Guided Biopsies"],"prefix":"10.1093","volume":"6","author":[{"given":"Orit","family":"Golan","sequence":"first","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sapir","family":"Lazar","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tehillah S","family":"Menes","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine Chaim Sheba Medical Center, Tel Aviv University , Tel Hashomer ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rivka","family":"Kessner","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tamar","family":"Shalmon","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rina","family":"Neeman","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Mercer","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoav","family":"Amitai","sequence":"additional","affiliation":[{"name":"Sackler School of Medicine, Tel Aviv University , Tel Aviv ,","place":["Israel"]},{"name":"Sourasky Medical Center , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,9,8]]},"reference":[{"issue":"2","key":"2024110602253832100_CIT0001","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1148\/radiology.205.2.9356622","article-title":"Clip placement after stereotactic vacuum-assisted breast biopsy","volume":"205","author":"Liberman","year":"1997","journal-title":"Radiology"},{"issue":"1","key":"2024110602253832100_CIT0002","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/1754-9485.13102","article-title":"Are breast biopsy markers underused","volume":"65","author":"Frost","year":"2021","journal-title":"J Med Imaging Radiat Oncol"},{"issue":"1065","key":"2024110602253832100_CIT0003","doi-asserted-by":"crossref","first-page":"20160149","DOI":"10.1259\/bjr.20160149","article-title":"A prospective comparative study to evaluate the displacement of four commercially available breast biopsy markers","volume":"89","author":"Pinkney","year":"2016","journal-title":"Br J Radiol"},{"issue":"1","key":"2024110602253832100_CIT0004","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.carj.2017.08.004","article-title":"Post\u2013vacuum-assisted stereotactic core biopsy clip displacement: a comparison between commercially available clips and surgical clip","volume":"69","author":"Yen","year":"2018","journal-title":"Can Assoc Radiol J"},{"issue":"6","key":"2024110602253832100_CIT0005","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1067\/j.cpradiol.2017.02.001","article-title":"Effect of mammography on marker clip migration after stereotactic-guided core needle breast biopsy","volume":"46","author":"Le-Petross","year":"2017","journal-title":"Curr Probl Diagn Radiol"},{"issue":"11","key":"2024110602253832100_CIT0006","doi-asserted-by":"crossref","first-page":"4797","DOI":"10.1007\/s00330-017-4851-7","article-title":"Stereotactic core needle breast biopsy marker migration: an analysis of factors contributing to immediate marker migration","volume":"27","author":"Jain","year":"2017","journal-title":"Eur Radiol"},{"issue":"11","key":"2024110602253832100_CIT0007","doi-asserted-by":"crossref","first-page":"6080","DOI":"10.1007\/s00330-020-07015-0","article-title":"Clip migration after stereotactic vacuum-assisted breast biopsy with the patient in the decubitus position","volume":"30","author":"Wang","year":"2020","journal-title":"Eur Radiol"},{"issue":"2","key":"2024110602253832100_CIT0008","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1148\/radiology.218.2.r01fe39510","article-title":"Metallic clip deployment during stereotactic breast biopsy: retrospective analysis","volume":"218","author":"Rosen","year":"2001","journal-title":"Radiology"},{"issue":"2","key":"2024110602253832100_CIT0009","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.acra.2019.03.022","article-title":"Immediate migration of biopsy clip markers after upright digital breast tomosynthesis-guided vacuum-assisted core biopsy","volume":"27","author":"Teichgraeber","year":"2020","journal-title":"Acad Radiol"},{"issue":"1","key":"2024110602253832100_CIT0010","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1186\/s13244-021-01136-w","article-title":"Does lateral arm technique decrease the rate of clip migration in stereotactic and tomosynthesis-guided biopsies","volume":"12","author":"Weaver","year":"2021","journal-title":"Insights Imaging"},{"issue":"3","key":"2024110602253832100_CIT0011","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1007\/s10549-011-1847-x","article-title":"A plea for the biopsy marker: how, why and why not clipping after breast biopsy","volume":"132","author":"Thomassin-Naggara","year":"2012","journal-title":"Breast Cancer Res Treat"},{"issue":"5","key":"2024110602253832100_CIT0012","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.2214\/ajr.181.5.1811295","article-title":"Accuracy of a collagen-plug biopsy site marking device deployed after stereotactic core needle breast biopsy","volume":"181","author":"Rosen","year":"2003","journal-title":"AJR Am J Roentgenol"},{"issue":"1 Pt 1","key":"2024110602253832100_CIT0013","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0221-0363(09)70075-7","article-title":"Clip migration after stereotactic macrobiopsy and presurgical localization: technical considerations and tricks. D\u00e9placement de clip post-macrobiopsie sous guidage st\u00e9r\u00e9otaxique et rep\u00e9rage pr\u00e9op\u00e9ratoire: trucs et astuces","volume":"90","author":"Chaveron","year":"2009","journal-title":"J Radiol"},{"issue":"2","key":"2024110602253832100_CIT0014","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1002\/jmri.26654","article-title":"Contrast-enhanced MRI for breast cancer screening","volume":"50","author":"Mann","year":"2019","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"2024110602253832100_CIT0015","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.amjsurg.2020.12.018","article-title":"The role of breast MRI in newly diagnosed breast cancer: an evidence-based review","volume":"221","author":"Thompson","year":"2021","journal-title":"Am J Surg"},{"issue":"4","key":"2024110602253832100_CIT0016","doi-asserted-by":"crossref","first-page":"377","DOI":"10.4048\/jbc.2021.24.e35","article-title":"Magnetic resonance imaging-guided breast biopsy in Korea: a 10-year follow-up experience","volume":"24","author":"Cha","year":"2021","journal-title":"J Breast Cancer"},{"issue":"6","key":"2024110602253832100_CIT0017","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1590\/0100-3984.2017.0132","article-title":"Magnetic resonance imaging-guided vacuum-assisted breast biopsy: experience and preliminary results of 205 procedures","volume":"51","author":"de Almeida Coutinho Carneiro","year":"2018","journal-title":"Radiol Bras"},{"issue":"7","key":"2024110602253832100_CIT0018","doi-asserted-by":"crossref","first-page":"4886","DOI":"10.1007\/s00330-020-07392-6","article-title":"Long-term MRI-guided vacuum-assisted breast biopsy results of 600 single-center procedures","volume":"31","author":"Lambert","year":"2021","journal-title":"Eur Radiol"},{"issue":"3","key":"2024110602253832100_CIT0019","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1111\/tbj.13486","article-title":"Tissue marker migration after MRI-guided breast biopsy: migration frequency and associated factors","volume":"26","author":"Funaro","year":"2020","journal-title":"Breast J"},{"issue":"1140","key":"2024110602253832100_CIT0020","doi-asserted-by":"crossref","first-page":"20220195","DOI":"10.1259\/bjr.20220195","article-title":"Immediate clip migration after breast biopsy: a meta-analysis for potential risk factors","volume":"95","author":"Lee","year":"2022","journal-title":"Br J Radiol"},{"issue":"1","key":"2024110602253832100_CIT0021","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s12282-011-0252-y","article-title":"Clip placement after an 11-gauge vacuum-assisted stereotactic breast biopsy: correlation between breast thickness and clip movement","volume":"19","author":"Uematsu","year":"2012","journal-title":"Breast Cancer"},{"issue":"4","key":"2024110602253832100_CIT0022","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/S0002-9610(02)00952-2","article-title":"Clip migration in stereotactic biopsy","volume":"184","author":"Kass","year":"2002","journal-title":"Am J Surg"},{"issue":"4","key":"2024110602253832100_CIT0023","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1046\/j.1524-4741.2003.09404.x","article-title":"Position of clip placement after vacuum-assisted breast biopsy: is a unilateral two-view postbiopsy mammogram necessary","volume":"9","author":"Lehman","year":"2003","journal-title":"Breast J"},{"issue":"1","key":"2024110602253832100_CIT0024","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1148\/rg.241035052","article-title":"Recognizing pitfalls in early and late migration of clip markers after imaging-guided directional vacuum-assisted biopsy","volume":"24","author":"Esserman","year":"2004","journal-title":"Radiographics"}],"container-title":["Journal of Breast Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jbi\/advance-article-pdf\/doi\/10.1093\/jbi\/wbae049\/60432389\/wbae049.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbi\/advance-article-pdf\/doi\/10.1093\/jbi\/wbae049\/60432389\/wbae049.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T21:25:51Z","timestamp":1730841951000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbi\/article\/6\/6\/621\/7750800"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,8]]},"references-count":24,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,9,8]]},"published-print":{"date-parts":[[2024,11,5]]}},"URL":"https:\/\/doi.org\/10.1093\/jbi\/wbae049","relation":{},"ISSN":["2631-6110","2631-6129"],"issn-type":[{"value":"2631-6110","type":"print"},{"value":"2631-6129","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,11]]},"published":{"date-parts":[[2024,9,8]]}}}