{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T23:38:54Z","timestamp":1740181134003,"version":"3.37.3"},"reference-count":48,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2024,9,23]],"date-time":"2024-09-23T00:00:00Z","timestamp":1727049600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"NIH\/NCI Cancer Center Support Grant","award":["P30 CA016672"],"award-info":[{"award-number":["P30 CA016672"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Image-guided biopsy is an integral step in the diagnosis and management of suspicious image-detected breast or axillary lesions, allowing for accurate diagnosis and, if indicated, treatment planning. Tissue sampling can be performed under guidance of a full spectrum of breast imaging modalities, including stereotactic, tomosynthesis, sonographic, and MRI, each with its own set of advantages and limitations. Procedural planning, which includes consideration of technical, patient, and lesion factors, is vital for diagnostic accuracy and limitation of complications. The purpose of this paper is to review and provide guidance for breast imaging radiologists in selecting the best procedural approach for the individual patient to ensure accurate diagnosis and optimal patient outcomes. Common patient and lesion factors that may affect successful sampling and contribute to postbiopsy complications are reviewed and include obesity, limited patient mobility, patient motion, patients prone to vasovagal reactions, history of anticoagulation, and lesion location, such as proximity to vital structures or breast implant.<\/jats:p>","DOI":"10.1093\/jbi\/wbae055","type":"journal-article","created":{"date-parts":[[2024,9,24]],"date-time":"2024-09-24T02:04:28Z","timestamp":1727143468000},"page":"658-667","source":"Crossref","is-referenced-by-count":1,"title":["Tips and Tricks for Image-Guided Breast Biopsies: Technical Factors for Success"],"prefix":"10.1093","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9138-4385","authenticated-orcid":false,"given":"Katerina","family":"Dodelzon","sequence":"first","affiliation":[{"name":"Department of Radiology, Weill Cornell Medicine at New York-Presbyterian , New York, NY ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3865-3352","authenticated-orcid":false,"given":"Lars","family":"Grimm","sequence":"additional","affiliation":[{"name":"Department of Radiology, Duke University Medical Center, Durham, NC ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kristen","family":"Coffey","sequence":"additional","affiliation":[{"name":"Department of Radiology, Weill Cornell Medicine at New York-Presbyterian , New York, NY ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6577-8601","authenticated-orcid":false,"given":"Beatriu","family":"Reig","sequence":"additional","affiliation":[{"name":"Department of Radiology, New York University Grossman School of Medicine , New York, NY ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3191-2865","authenticated-orcid":false,"given":"Lisa","family":"Mullen","sequence":"additional","affiliation":[{"name":"Department of Radiology , Johns Hopkins Medicine, Baltimore, MD ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brittany Z","family":"Dashevsky","sequence":"additional","affiliation":[{"name":"Department of Radiology, Stanford University School of Medicine , Stanford, CA ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sonya","family":"Bhole","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Feinberg School of Medicine , Chicago IL ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jay","family":"Parikh","sequence":"additional","affiliation":[{"name":"Department of Radiology, The University of Texas MD Anderson Cancer Center , Houston, TX ,","place":["USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,9,23]]},"reference":[{"issue":"4","key":"2024110602253702400_CIT0001","doi-asserted-by":"crossref","first-page":"238","DOI":"10.7326\/0003-4819-152-1-201001050-00190","article-title":"Systematic review: comparative effectiveness of core-needle and open surgical biopsy to diagnose breast lesions","volume":"152","author":"Bruening","year":"2010","journal-title":"Ann Intern Med"},{"author":"American College of Radiology","key":"2024110602253702400_CIT0002"},{"journal-title":"ACR practice parameter for the performance of stereotactic-guided breast interventional procedures","author":"American College of Radiology","key":"2024110602253702400_CIT0003"},{"author":"American College of Radiology","key":"2024110602253702400_CIT0004"},{"issue":"May-June","key":"2024110602253702400_CIT0005","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.pcad.2023.05.003","article-title":"Heart failure and obesity: the latest pandemic","volume":"78","author":"Aryee","year":"2023","journal-title":"Prog Cardiovasc Dis"},{"issue":"4","key":"2024110602253702400_CIT0006","doi-asserted-by":"crossref","first-page":"941","DOI":"10.2214\/ajr.180.4.1800941","article-title":"Sonographic detection and sonographically guided biopsy of breast microcalcifications","volume":"180","author":"Soo","year":"2003","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2024110602253702400_CIT0007","doi-asserted-by":"crossref","first-page":"296","DOI":"10.2214\/AJR.10.5556","article-title":"Breast imaging and intervention in the overweight and obese patient","volume":"196","author":"Destounis","year":"2011","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2024110602253702400_CIT0008","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1053\/j.tvir.2013.12.006","article-title":"Stereotactic breast biopsy: pitfalls and pearls","volume":"17","author":"Huang","year":"2014","journal-title":"Tech Vasc Interv Radiol"},{"year":"2024","author":"Afirm Prone Biopsy System","key":"2024110602253702400_CIT0009"},{"key":"2024110602253702400_CIT0010"},{"author":"Medical Positioning, Inc","key":"2024110602253702400_CIT0011"},{"issue":"11","key":"2024110602253702400_CIT0012","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1016\/j.acra.2017.05.010","article-title":"Implementation of upright digital breast tomosynthesis-guided stereotactic biopsy","volume":"24","author":"Omofoye","year":"2017","journal-title":"Acad Radiol"},{"issue":"2","key":"2024110602253702400_CIT0013","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1148\/radiol.2018181788","article-title":"Comparison of upright digital breast tomosynthesis-guided versus prone stereotactic vacuum-assisted breast biopsy","volume":"290","author":"Bahl","year":"2019","journal-title":"Radiology"},{"issue":"5","key":"2024110602253702400_CIT0014","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1016\/j.jacr.2015.12.004","article-title":"Imaging-guided core-needle breast biopsy: impact of meditation and music interventions on patient anxiety, pain, and fatigue","volume":"13","author":"Soo","year":"2016","journal-title":"J Am Coll Radiol"},{"issue":"11S","key":"2024110602253702400_CIT0015","doi-asserted-by":"crossref","first-page":"e62","DOI":"10.1016\/j.jacr.2016.09.034","article-title":"Patient anxiety before and immediately after imaging-guided breast biopsy procedures: impact of radiologist-patient communication","volume":"13","author":"Miller","year":"2016","journal-title":"J Am Coll Radiol"},{"issue":"1","key":"2024110602253702400_CIT0016","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1053\/j.tvir.2013.12.007","article-title":"Breast magnetic resonance imaging for the interventionalist: magnetic resonance imaging\u2013guided vacuum-assisted breast biopsy","volume":"17","author":"Brennan","year":"2014","journal-title":"Tech Vasc Interv Radiol"},{"issue":"5","key":"2024110602253702400_CIT0017","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.2214\/ajr.178.5.1781221","article-title":"Comparison of sitting versus prone position for stereotactic large-core breast biopsy in surgically proven lesions","volume":"178","author":"Wunderbaldinger","year":"2002","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"2024110602253702400_CIT0018","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.2214\/ajr.178.4.1781017","article-title":"Stereotactic biopsy of the breast using an upright unit, a vacuum-suction needle, and a lateral arm-support system","volume":"178","author":"Georgian-Smith","year":"2002","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2024110602253702400_CIT0019","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1093\/jbi\/wbac020","article-title":"Bleeding complications after breast core-needle biopsy\u2013an approach to managing patients on antithrombotic therapy","volume":"4","author":"Goudreau","year":"2022","journal-title":"J Breast Imaging"},{"issue":"8","key":"2024110602253702400_CIT0020","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1016\/j.jvir.2019.04.017","article-title":"Society of Interventional Radiology consensus guidelines for the periprocedural management of thrombotic and bleeding risk in patients undergoing percutaneous image-guided interventions\u2014part II: recommendations","volume":"30","author":"Patel","year":"2019","journal-title":"J Vasc Interv Radiol"},{"key":"2024110602253702400_CIT0021","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.clinimag.2020.09.014","article-title":"Bleeding risk after percutaneous breast needle biopsy in patients on anticoagulation therapy","volume":"70","author":"McMahon","year":"2021","journal-title":"Clin Imaging"},{"issue":"1","key":"2024110602253702400_CIT0022","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1148\/radiol.220548","article-title":"Antithrombotic therapy and hematoma risk during image-guided core-needle breast biopsy","volume":"306","author":"Loving","year":"2023","journal-title":"Radiology"},{"issue":"4","key":"2024110602253702400_CIT0023","doi-asserted-by":"crossref","first-page":"438","DOI":"10.2214\/AJR.23.29164","article-title":"Bleeding events after image-guided breast biopsies: comparison of patients temporarily discontinuing versus maintaining antithrombotic therapy during biopsy","volume":"221","author":"Reichman","year":"2023","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2024110602253702400_CIT0024","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1148\/radiol.13120985","article-title":"Breast intervention: how I do it","volume":"268","author":"Mahoney","year":"2013","journal-title":"Radiology"},{"issue":"3","key":"2024110602253702400_CIT0025","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1148\/rg.2017160117","article-title":"Troubleshooting to overcome technical challenges in image-guided breast biopsy","volume":"37","author":"Chesebro","year":"2017","journal-title":"Radiographics"},{"issue":"11","key":"2024110602253702400_CIT0026","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1001\/jama.2018.12615","article-title":"Association of clinical specialty with symptoms of burnout and career choice regret among U.S. resident physicians","volume":"320","author":"Dyrbye","year":"2018","journal-title":"JAMA"},{"issue":"5","key":"2024110602253702400_CIT0027","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1148\/rg.2021210017","article-title":"Upright tomosynthesis-guided breast biopsy: tips, tricks, and troubleshooting","volume":"41","author":"Vijapura","year":"2021","journal-title":"Radiographics"},{"issue":"1","key":"2024110602253702400_CIT0028","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1038\/s41598-020-80124-4","article-title":"Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions","volume":"11","author":"Bohan","year":"2021","journal-title":"Sci Rep"},{"issue":"1","key":"2024110602253702400_CIT0029","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1186\/s13244-021-01136-w","article-title":"Does lateral arm technique decrease the rate of clip migration in stereotactic and tomosynthesis-guided biopsies","volume":"12","author":"Weaver","year":"2021","journal-title":"Insights Imaging"},{"issue":"1","key":"2024110602253702400_CIT0030","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1148\/radiol.2221010231","article-title":"Stereotactic histologic biopsy in breasts with implants","volume":"222","author":"Jackman","year":"2002","journal-title":"Radiology"},{"issue":"4","key":"2024110602253702400_CIT0031","doi-asserted-by":"crossref","first-page":"512","DOI":"10.2214\/AJR.22.28572","article-title":"Challenging contrast-enhanced mammography-guided biopsies: practical approach using real-time multimodality imaging and a proposed procedural algorithm","volume":"220","author":"Weaver","year":"2023","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2024110602253702400_CIT0032","doi-asserted-by":"crossref","first-page":"E46","DOI":"10.1148\/rg.210126","article-title":"MRI-guided breast biopsy case-based review: essential techniques and approaches to challenging cases","volume":"42","author":"Adrada","year":"2022","journal-title":"Radiographics"},{"issue":"2","key":"2024110602253702400_CIT0033","doi-asserted-by":"crossref","first-page":"306","DOI":"10.2214\/AJR.19.22082","article-title":"Minimally invasive breast procedures: practical tips and tricks","volume":"214","author":"Huppe","year":"2020","journal-title":"AJR Am J Roentgenol"},{"year":"2021","author":"American College of Radiology","key":"2024110602253702400_CIT0034"},{"issue":"2","key":"2024110602253702400_CIT0035","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1148\/radiology.205.2.9356622","article-title":"Clip placement after stereotactic vacuum-assisted breast biopsy","volume":"205","author":"Liberman","year":"1997","journal-title":"Radiology"},{"issue":"4","key":"2024110602253702400_CIT0036","doi-asserted-by":"crossref","first-page":"927","DOI":"10.2214\/AJR.17.18489","article-title":"Sonographic-MRI correlation after percutaneous sampling of targeted breast ultrasound lesions: initial experiences with limited-sequence unenhanced MRI for postprocedural clip localization","volume":"210","author":"Lee","year":"2018","journal-title":"AJR Am J Roentgenol"},{"journal-title":"ACR practice parameter for the performance of contrast enhanced magnetic resonance imaging (MRI) of the breast","year":"2023","author":"American College of Radiology","key":"2024110602253702400_CIT0037"},{"issue":"6","key":"2024110602253702400_CIT0038","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.2214\/AJR.18.20577","article-title":"Biopsy marker standardization: what\u2019s in a name","volume":"212","author":"Portnow","year":"2019","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2024110602253702400_CIT0039","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1007\/s00404-021-06085-9","article-title":"Evaluation of sonographic detectability of different markers within an in vitro simulation model of the axilla","volume":"304","author":"Guergan","year":"2021","journal-title":"Arch Gynecol Obstet"},{"issue":"2","key":"2024110602253702400_CIT0040","doi-asserted-by":"crossref","first-page":"372","DOI":"10.2214\/AJR.05.1254","article-title":"Effects on breast MRI of artifacts caused by metallic tissue marker clips","volume":"188","author":"Genson","year":"2007","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"2024110602253702400_CIT0041","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1097\/DER.0000000000000819","article-title":"Allergic sensitization to nickel and implanted metal devices: a perspective","volume":"33","author":"Kimber","year":"2022","journal-title":"Dermatitis"},{"author":"Merit Medical","key":"2024110602253702400_CIT0042"},{"issue":"1","key":"2024110602253702400_CIT0043","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/BF02967485","article-title":"A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy","volume":"8","author":"Tamai","year":"2001","journal-title":"Breast Cancer"},{"issue":"2","key":"2024110602253702400_CIT0044","first-page":"e34929","article-title":"Diagnosis and management of a hypersensitivity reaction to titanium-containing surgical clips: a case report","volume":"15","author":"Ramcharan","year":"2023","journal-title":"Cureus"},{"issue":"4","key":"2024110602253702400_CIT0045","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/j.1600-0536.2006.00931.x","article-title":"Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature","volume":"55","author":"Thomas","year":"2006","journal-title":"Contact Dermatitis"},{"issue":"1","key":"2024110602253702400_CIT0046","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.ultrasmedbio.2016.08.024","article-title":"Detection and removal of ceramic clip markers from breast tissue by ultrasound-guided, vacuum-assisted minimally invasive biopsy in a Turkey breast model","volume":"43","author":"Schaefgen","year":"2017","journal-title":"Ultrasound Med Biol"},{"issue":"1085","key":"2024110602253702400_CIT0047","doi-asserted-by":"crossref","first-page":"20170740","DOI":"10.1259\/bjr.20170740","article-title":"Innovations in image-guided preoperative breast lesion localization","volume":"91","author":"Cheang","year":"2018","journal-title":"Br J Radiol"},{"issue":"1","key":"2024110602253702400_CIT0048","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1148\/rg.241035052","article-title":"Recognizing pitfalls in early and late migration of clip markers after imaging-guided directional vacuum-assisted biopsy","volume":"24","author":"Esserman","year":"2004","journal-title":"Radiographics"}],"container-title":["Journal of Breast Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jbi\/advance-article-pdf\/doi\/10.1093\/jbi\/wbae055\/60432362\/wbae055.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbi\/advance-article-pdf\/doi\/10.1093\/jbi\/wbae055\/60432362\/wbae055.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,6]],"date-time":"2024-11-06T02:25:55Z","timestamp":1730859955000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbi\/article\/6\/6\/658\/7769680"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,23]]},"references-count":48,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,9,23]]},"published-print":{"date-parts":[[2024,11,5]]}},"URL":"https:\/\/doi.org\/10.1093\/jbi\/wbae055","relation":{},"ISSN":["2631-6110","2631-6129"],"issn-type":[{"type":"print","value":"2631-6110"},{"type":"electronic","value":"2631-6129"}],"subject":[],"published-other":{"date-parts":[[2024,11]]},"published":{"date-parts":[[2024,9,23]]}}}