{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T02:32:50Z","timestamp":1790994770021,"version":"4.1.0"},"reference-count":76,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2024,12,7]],"date-time":"2024-12-07T00:00:00Z","timestamp":1733529600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,1,25]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Invasive lobular carcinoma (ILC) is the second-most common histologic subtype of breast cancer, constituting 5% to 15% of all breast cancers. It is characterized by an infiltrating growth pattern that may decrease detectability on mammography and US. The use of digital breast tomosynthesis (DBT) improves conspicuity of ILC, and sensitivity is 80% to 88% for ILC. Sensitivity of mammography is lower in dense breasts, and breast tomosynthesis has better sensitivity for ILC in dense breasts compared with digital mammography (DM). Screening US identifies additional ILCs even after DBT, with a supplemental cancer detection rate of 0 to 1.2 ILC per 1000 examinations. Thirteen percent of incremental cancers found by screening US are ILCs. Breast MRI has a sensitivity of 93% for ILC. Abbreviated breast MRI also has high sensitivity but may be limited due to delayed enhancement in ILC. Contrast-enhanced mammography has improved sensitivity for ILC compared with DM, with higher specificity than breast MRI. In summary, supplemental screening modalities increase detection of ILC, with MRI demonstrating the highest sensitivity.<\/jats:p>","DOI":"10.1093\/jbi\/wbae082","type":"journal-article","created":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T04:14:39Z","timestamp":1730434479000},"page":"3-15","source":"Crossref","is-referenced-by-count":9,"title":["Invasive Lobular Carcinoma in the Screening Setting"],"prefix":"10.1093","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6577-8601","authenticated-orcid":false,"given":"Beatriu","family":"Reig","sequence":"first","affiliation":[{"name":"Department of Radiology, NYU Grossman School of Medicine , New York, NY ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0900-0459","authenticated-orcid":false,"given":"Laura","family":"Heacock","sequence":"additional","affiliation":[{"name":"Department of Radiology, NYU Grossman School of Medicine , New York, NY ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,12,7]]},"reference":[{"key":"2025012707411431400_CIT0001","doi-asserted-by":"publisher","first-page":"590643","DOI":"10.3389\/fonc.2020.590643","article-title":"Comparison of overall survival between invasive lobular breast carcinoma and invasive ductal breast carcinoma: a propensity score matching study based on SEER database","volume":"10","author":"Yang","year":"2020","journal-title":"Front Oncol"},{"issue":"1","key":"2025012707411431400_CIT0002","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s13058-015-0519-x","article-title":"Invasive lobular carcinoma of the breast: morphology, biomarkers and \u2019omics","volume":"17","author":"McCart Reed","year":"2015","journal-title":"Breast Cancer Res"},{"issue":"6","key":"2025012707411431400_CIT0003","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.2214\/AJR.19.22027","article-title":"Imaging of breast cancers with predilection for nonmass pattern of growth: invasive lobular carcinoma and DCIS\u2013does imaging capture it all","volume":"215","author":"Weaver","year":"2020","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2025012707411431400_CIT0004","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1080\/03630242.2022.2030448","article-title":"Clinical differences between invasive lobular breast cancer and invasive carcinoma of no special type in the German mammography-screening-program","volume":"62","author":"Farrokh","year":"2022","journal-title":"Women Health"},{"issue":"3","key":"2025012707411431400_CIT0005","doi-asserted-by":"publisher","first-page":"R149","DOI":"10.1186\/bcr767","article-title":"Infiltrating lobular carcinoma of the breast: tumor characteristics and clinical outcome","volume":"6","author":"Arpino","year":"2004","journal-title":"Breast Cancer Res"},{"issue":"1","key":"2025012707411431400_CIT0006","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10549-007-9528-5","article-title":"MRI compared to conventional diagnostic work-up in the detection and evaluation of invasive lobular carcinoma of the breast: a review of existing literature","volume":"107","author":"Mann","year":"2008","journal-title":"Breast Cancer Res Treat"},{"issue":"9","key":"2025012707411431400_CIT0007","doi-asserted-by":"publisher","first-page":"e0182397","DOI":"10.1371\/journal.pone.0182397","article-title":"Invasive lobular carcinoma of the breast: a special histological type compared with invasive ductal carcinoma","volume":"12","author":"Chen","year":"2017","journal-title":"PLoS One"},{"issue":"6","key":"2025012707411431400_CIT0008","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1038\/s41416-022-02131-8","article-title":"Mixed invasive ductal lobular carcinoma is clinically and pathologically more similar to invasive lobular than ductal carcinoma","volume":"128","author":"Nasrazadani","year":"2023","journal-title":"Br J Cancer"},{"key":"2025012707411431400_CIT0009","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1186\/2193-1801-2-621","article-title":"Invasive ductolobular carcinoma of the breast: spectrum of mammographic, ultrasound and magnetic resonance imaging findings correlated with proportion of the lobular component","volume":"2","author":"Menezes","year":"2013","journal-title":"Springerplus"},{"issue":"4","key":"2025012707411431400_CIT0010","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1002\/cncr.31840","article-title":"The incidence of fatal breast cancer measures the increased effectiveness of therapy in women participating in mammography screening","volume":"125","author":"Tab\u00e1r","year":"2019","journal-title":"Cancer"},{"issue":"4","key":"2025012707411431400_CIT0011","doi-asserted-by":"publisher","first-page":"E115","DOI":"10.1148\/rg.210058","article-title":"Invasive lobular carcinoma: a multimodality imaging primer","volume":"42","author":"Manning","year":"2022","journal-title":"Radiographics"},{"issue":"3","key":"2025012707411431400_CIT0012","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1148\/radiology.184.3.1324506","article-title":"Invasive lobular and ductal carcinoma: mammographic findings and stage at diagnosis","volume":"184","author":"Newstead","year":"1992","journal-title":"Radiology"},{"issue":"1","key":"2025012707411431400_CIT0013","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1148\/radiol.2251011029","article-title":"Invasive lobular carcinoma of the breast: mammographic characteristics and computer-aided detection","volume":"225","author":"Evans","year":"2002","journal-title":"Radiology"},{"issue":"23","key":"2025012707411431400_CIT0014","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1093\/jnci\/91.23.2020","article-title":"Breast tumor characteristics as predictors of mammographic detection: comparison of interval- and screen-detected cancers","volume":"91","author":"Porter","year":"1999","journal-title":"J Natl Cancer Inst"},{"issue":"3","key":"2025012707411431400_CIT0015","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1148\/radiology.185.3.1438749","article-title":"Mammographic features of 455 invasive lobular carcinomas","volume":"185","author":"Le Gal","year":"1992","journal-title":"Radiology"},{"issue":"1","key":"2025012707411431400_CIT0016","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/1754-9485.12080","article-title":"Mammographic and ultrasound features of invasive lobular carcinoma of the breast","volume":"58","author":"Porter","year":"2014","journal-title":"J Med Imaging Radiat Oncol"},{"issue":"5","key":"2025012707411431400_CIT0017","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1001\/jamaoncol.2018.7078","article-title":"Association of digital breast tomosynthesis vs digital mammography with cancer detection and recall rates by age and breast density","volume":"5","author":"Conant","year":"2019","journal-title":"JAMA Oncol"},{"key":"2025012707411431400_CIT0018","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.breast.2018.01.002","article-title":"Interval breast cancers in the \u2018screening with tomosynthesis or standard mammography\u2019 (STORM) population-based trial","volume":"38","author":"Houssami","year":"2018","journal-title":"Breast"},{"issue":"2","key":"2025012707411431400_CIT0019","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1148\/radiol.2019191337","article-title":"Interval and consecutive round breast cancer after digital breast tomosynthesis and synthetic 2D mammography versus standard 2D digital mammography in BreastScreen Norway","volume":"294","author":"Hovda","year":"2020","journal-title":"Radiology"},{"issue":"1073","key":"2025012707411431400_CIT0020","doi-asserted-by":"publisher","first-page":"20170128","DOI":"10.1259\/bjr.20170128","article-title":"Imaging features and conspicuity of invasive lobular carcinomas on digital breast tomosynthesis","volume":"90","author":"Chamming\u2019s","year":"2017","journal-title":"Br J Radiol"},{"issue":"9","key":"2025012707411431400_CIT0021","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1016\/j.crad.2016.04.004","article-title":"Digital breast tomosynthesis as an adjunct to digital mammography for detecting and characterising invasive lobular cancers: a multi-reader study","volume":"71","author":"Mariscotti","year":"2016","journal-title":"Clin Radiol"},{"issue":"1","key":"2025012707411431400_CIT0022","doi-asserted-by":"publisher","first-page":"58","DOI":"10.3348\/kjr.2018.0012","article-title":"Factors affecting breast cancer detectability on digital breast tomosynthesis and two-dimensional digital mammography in patients with dense breasts","volume":"20","author":"Lee","year":"2019","journal-title":"Korean J Radiol"},{"issue":"6","key":"2025012707411431400_CIT0023","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.2214\/AJR.17.18195","article-title":"Biologic profiles of invasive breast cancers detected only with digital breast tomosynthesis","volume":"209","author":"Kim","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"2025012707411431400_CIT0024","doi-asserted-by":"publisher","first-page":"3912","DOI":"10.1007\/s00330-023-10400-0","article-title":"Discordant and false-negative interpretations at digital breast tomosynthesis in the prospective Oslo Tomosynthesis Screening Trial (OTST) using independent double reading","volume":"34","author":"Skaane","year":"2024","journal-title":"Eur Radiol"},{"issue":"7","key":"2025012707411431400_CIT0025","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","article-title":"Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study","volume":"14","author":"Ciatto","year":"2013","journal-title":"Lancet Oncol"},{"issue":"3","key":"2025012707411431400_CIT0026","doi-asserted-by":"publisher","first-page":"e221785","DOI":"10.1148\/radiol.221785","article-title":"Supplemental breast cancer screening in women with dense breasts and negative mammography: a systematic review and meta-analysis","volume":"306","author":"Hussein","year":"2023","journal-title":"Radiology"},{"issue":"3","key":"2025012707411431400_CIT0027","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1007\/s10549-023-07051-6","article-title":"Digital mammography and digital breast tomosynthesis for detecting invasive lobular and ductal carcinoma","volume":"202","author":"Onega","year":"2023","journal-title":"Breast Cancer Res Treat"},{"key":"2025012707411431400_CIT0028","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1093\/jbi\/wbad112","article-title":"Breast radiologists\u2019 perceptions on the detection and management of invasive lobular carcinoma: most agree imaging beyond mammography is warranted. J Breast Imaging","author":"Coffey","year":"2024"},{"issue":"3","key":"2025012707411431400_CIT0029","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1016\/j.clinimag.2012.09.018","article-title":"Improved breast cancer detection in asymptomatic women using 3D-automated breast ultrasound in mammographically dense breasts","volume":"37","author":"Giuliano","year":"2013","journal-title":"Clin Imaging"},{"issue":"6","key":"2025012707411431400_CIT0030","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.2214\/AJR.12.9672","article-title":"Implementation of breast tomosynthesis in a routine screening practice: an observational study","volume":"200","author":"Rose","year":"2013","journal-title":"AJR Am J Roentgenol"},{"issue":"24","key":"2025012707411431400_CIT0031","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1001\/jama.2014.6095","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography","volume":"311","author":"Friedewald","year":"2014","journal-title":"JAMA"},{"issue":"3","key":"2025012707411431400_CIT0032","doi-asserted-by":"publisher","first-page":"687","DOI":"10.2214\/AJR.14.12642","article-title":"Clinical performance metrics of 3D digital breast tomosynthesis compared with 2D digital mammography for breast cancer screening in community practice","volume":"203","author":"Greenberg","year":"2014","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2025012707411431400_CIT0033","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1148\/radiol.14132832","article-title":"Assessing improvement in detection of breast cancer with three-dimensional automated breast US in women with dense breast tissue: the SomoInsight Study","volume":"274","author":"Brem","year":"2015","journal-title":"Radiology"},{"issue":"6","key":"2025012707411431400_CIT0034","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1111\/tbj.12649","article-title":"Breast cancers found with digital breast tomosynthesis: a comparison of pathology and histologic grade","volume":"22","author":"Wang","year":"2016","journal-title":"Breast J"},{"issue":"8","key":"2025012707411431400_CIT0035","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1016\/S1470-2045(16)30101-2","article-title":"Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study","volume":"17","author":"Bernardi","year":"2016","journal-title":"Lancet Oncol"},{"issue":"11","key":"2025012707411431400_CIT0036","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.1016\/S1470-2045(18)30521-7","article-title":"One-view breast tomosynthesis versus two-view mammography in the Malm\u00f6 Breast Tomosynthesis Screening Trial (MBTST): a prospective, population-based, diagnostic accuracy study","volume":"19","author":"Zackrisson","year":"2018","journal-title":"Lancet Oncol"},{"issue":"3","key":"2025012707411431400_CIT0037","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1148\/radiol.2018171361","article-title":"Digital breast tomosynthesis and synthetic 2D mammography versus digital mammography: evaluation in a population-based screening program","volume":"287","author":"Hofvind","year":"2018","journal-title":"Radiology"},{"issue":"6","key":"2025012707411431400_CIT0038","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/S1470-2045(19)30161-5","article-title":"Two-view digital breast tomosynthesis versus digital mammography in a population-based breast cancer screening programme (To-Be): a randomised, controlled trial","volume":"20","author":"Hofvind","year":"2019","journal-title":"Lancet Oncol"},{"issue":"1","key":"2025012707411431400_CIT0039","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1148\/radiol.2021203936","article-title":"Interval and subsequent round breast cancer in a randomized controlled trial comparing digital breast tomosynthesis and digital mammography screening","volume":"300","author":"Hofvind","year":"2021","journal-title":"Radiology"},{"issue":"2","key":"2025012707411431400_CIT0040","doi-asserted-by":"publisher","first-page":"275","DOI":"10.2214\/AJR.20.24436","article-title":"Screening algorithms in dense breasts: AJR Expert Panel narrative review","volume":"216","author":"Berg","year":"2021","journal-title":"AJR Am J Roentgenol"},{"issue":"10016","key":"2025012707411431400_CIT0041","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/S0140-6736(15)00774-6","article-title":"Sensitivity and specificity of mammography and adjunctive ultrasonography to screen for breast cancer in the Japan Strategic Anti-cancer Randomized Trial (J-START): a randomised controlled trial","volume":"387","author":"Ohuchi","year":"2016","journal-title":"Lancet"},{"issue":"1","key":"2025012707411431400_CIT0042","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s12282-013-0498-7","article-title":"Ultrasonographic findings of missed breast cancer: pitfalls and pearls","volume":"21","author":"Uematsu","year":"2014","journal-title":"Breast Cancer"},{"issue":"4","key":"2025012707411431400_CIT0043","doi-asserted-by":"publisher","first-page":"371","DOI":"10.2325\/jbcs.14.371","article-title":"The role of contrast enhanced MRI in the diagnosis of non-mass image-forming lesions on breast ultrasonography","volume":"14","author":"Sotome","year":"2007","journal-title":"Breast Cancer"},{"key":"2025012707411431400_CIT0044","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1186\/1471-2407-13-328","article-title":"Measurement of tumour size with mammography, sonography and magnetic resonance imaging as compared to histological tumour size in primary breast cancer","volume":"13","author":"Gruber","year":"2013","journal-title":"BMC Cancer"},{"issue":"7","key":"2025012707411431400_CIT0045","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1002\/jcu.20052","article-title":"Role of sonography in diagnosing and staging invasive lobular carcinoma","volume":"32","author":"Selinko","year":"2004","journal-title":"J Clin Ultrasound"},{"issue":"2","key":"2025012707411431400_CIT0046","doi-asserted-by":"publisher","first-page":"325","DOI":"10.2214\/ajr.172.2.9930776","article-title":"Sonographic evaluation of infiltrating lobular carcinoma","volume":"172","author":"Butler","year":"1999","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2025012707411431400_CIT0047","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.acra.2021.01.008","article-title":"Comparison of cancers detected by screening breast ultrasound and digital breast tomosynthesis","volume":"29","author":"Destounis","year":"2022","journal-title":"Acad Radiol"},{"issue":"13","key":"2025012707411431400_CIT0048","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1001\/jama.2012.388","article-title":"Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk","volume":"307","author":"Berg","year":"2012","journal-title":"JAMA"},{"issue":"13","key":"2025012707411431400_CIT0049","doi-asserted-by":"publisher","first-page":"2403","DOI":"10.1200\/JCO.22.01445","article-title":"Prospective multicenter diagnostic performance of technologist-performed screening breast ultrasound after tomosynthesis in women with dense breasts (the DBTUST)","volume":"41","author":"Berg","year":"2023","journal-title":"J Clin Oncol"},{"issue":"16","key":"2025012707411431400_CIT0050","doi-asserted-by":"publisher","first-page":"1882","DOI":"10.1200\/JCO.2015.63.4147","article-title":"Adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts: interim report of a prospective comparative trial","volume":"34","author":"Tagliafico","year":"2016","journal-title":"J Clin Oncol"},{"key":"2025012707411431400_CIT0051","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ejca.2018.08.029","article-title":"A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2)","volume":"104","author":"Tagliafico","year":"2018","journal-title":"Eur J Cancer"},{"issue":"3","key":"2025012707411431400_CIT0052","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1055\/s-0040-1722156","article-title":"Comparison of automated breast ultrasound and hand-held breast ultrasound in the screening of dense breasts","volume":"43","author":"Philadelpho","year":"2021","journal-title":"Rev Bras Ginecol Obstet"},{"issue":"9","key":"2025012707411431400_CIT0053","doi-asserted-by":"publisher","first-page":"2170","DOI":"10.3390\/diagnostics12092170","article-title":"A prospective comparative evaluation of handheld ultrasound examination (HHUS) or automated ultrasound examination (ABVS) in women with dense breast","volume":"12","author":"Brunetti","year":"2022","journal-title":"Diagnostics (Basel)."},{"issue":"5","key":"2025012707411431400_CIT0054","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1001\/jamainternmed.2018.8372","article-title":"Performance of screening ultrasonography as an adjunct to screening mammography in women across the spectrum of breast cancer risk","volume":"179","author":"Lee","year":"2019","journal-title":"JAMA Intern. Med"},{"key":"2025012707411431400_CIT0055","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.ejrad.2018.01.022","article-title":"Combined screening with mammography and ultrasound in a population-based screening program","volume":"101","author":"Buchberger","year":"2018","journal-title":"Eur J Radiol"},{"issue":"2","key":"2025012707411431400_CIT0056","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1093\/jbi\/wbaa006","article-title":"A prospective study of automated breast ultrasound screening of women with dense breasts in a digital breast tomosynthesis-based practice","volume":"2","author":"Chough","year":"2020","journal-title":"J Breast Imaging"},{"issue":"4","key":"2025012707411431400_CIT0057","doi-asserted-by":"publisher","first-page":"274","DOI":"10.3348\/kjr.2022.0649","article-title":"Digital breast tomosynthesis plus ultrasound versus digital mammography plus ultrasound for screening breast cancer in women with dense breasts","volume":"24","author":"Ha","year":"2023","journal-title":"Korean J Radiol"},{"issue":"2","key":"2025012707411431400_CIT0058","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1002\/jmri.22632","article-title":"Comparison of enhancement characteristics between invasive lobular carcinoma and invasive ductal carcinoma","volume":"34","author":"Mann","year":"2011","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2025012707411431400_CIT0059","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1053\/ejso.2002.1391","article-title":"Dynamic contrast enhanced magnetic resonance imaging aids the surgical management of invasive lobular breast cancer","volume":"29","author":"Kneeshaw","year":"2003","journal-title":"Eur J Surg Oncol"},{"issue":"22","key":"2025012707411431400_CIT0060","doi-asserted-by":"publisher","first-page":"2304","DOI":"10.1200\/JCO.2013.52.5386","article-title":"Abbreviated breast magnetic resonance imaging (MRI): first postcontrast subtracted images and maximum-intensity projection-a novel approach to breast cancer screening with MRI","volume":"32","author":"Kuhl","year":"2014","journal-title":"J Clin Oncol"},{"issue":"2","key":"2025012707411431400_CIT0061","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1148\/radiol.2016161444","article-title":"Supplemental breast MR imaging screening of women with average risk of breast cancer","volume":"283","author":"Kuhl","year":"2017","journal-title":"Radiology"},{"issue":"22","key":"2025012707411431400_CIT0062","doi-asserted-by":"publisher","first-page":"2091","DOI":"10.1056\/NEJMoa1903986","article-title":"Supplemental MRI screening for women with extremely dense breast tissue","volume":"381","author":"Bakker","year":"2019","journal-title":"N Engl J Med"},{"issue":"9","key":"2025012707411431400_CIT0063","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/j.jacr.2023.04.002","article-title":"Breast cancer screening for women at higher-than-average risk: updated recommendations from the ACR","volume":"20","author":"Monticciolo","year":"2023","journal-title":"J Am Coll Radiol"},{"issue":"1","key":"2025012707411431400_CIT0064","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1148\/radiol.2021202927","article-title":"Breast cancer screening with abbreviated breast MRI: 3-year outcome analysis","volume":"299","author":"Kwon","year":"2021","journal-title":"Radiology"},{"issue":"2","key":"2025012707411431400_CIT0065","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1148\/radiol.2021203633","article-title":"Supplemental breast MRI for women with extremely dense breasts: results of the second screening round of the DENSE trial","volume":"299","author":"Veenhuizen","year":"2021","journal-title":"Radiology"},{"issue":"2","key":"2025012707411431400_CIT0066","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.diii.2016.08.013","article-title":"Contrast-enhanced spectral mammography (CESM) versus breast magnetic resonance imaging (MRI): a retrospective comparison in 66 breast lesions","volume":"98","author":"Li","year":"2017","journal-title":"Diagn Interv Imaging"},{"issue":"1","key":"2025012707411431400_CIT0067","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1148\/radiol.212530","article-title":"Contrast-enhanced mammography versus contrast-enhanced breast MRI: a systematic review and meta-analysis","volume":"305","author":"P\u00f6tsch","year":"2022","journal-title":"Radiology"},{"issue":"3","key":"2025012707411431400_CIT0068","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1148\/radiol.12121084","article-title":"Bilateral contrast-enhanced dual-energy digital mammography: feasibility and comparison with conventional digital mammography and MR imaging in women with known breast carcinoma","volume":"266","author":"Jochelson","year":"2013","journal-title":"Radiology"},{"issue":"1","key":"2025012707411431400_CIT0069","doi-asserted-by":"publisher","first-page":"20180046","DOI":"10.1259\/bjro.20180046","article-title":"Differences in degree of lesion enhancement on CEM between ILC and IDC","volume":"1","author":"van Nijnatten","year":"2019","journal-title":"BJR Open"},{"key":"2025012707411431400_CIT0070","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ejrad.2017.10.001","article-title":"Comparison of screening CEDM and MRI for women at increased risk for breast cancer: a pilot study","volume":"97","author":"Jochelson","year":"2017","journal-title":"Eur J Radiol"},{"issue":"1","key":"2025012707411431400_CIT0071","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1148\/radiol.2019182660","article-title":"Performance of dual-energy contrast-enhanced digital mammography for screening women at increased risk of breast cancer","volume":"293","author":"Sung","year":"2019","journal-title":"Radiology"},{"issue":"5","key":"2025012707411431400_CIT0072","doi-asserted-by":"publisher","first-page":"W267","DOI":"10.2214\/AJR.17.19355","article-title":"Contrast-enhanced spectral mammography in women with intermediate breast cancer risk and dense breasts","volume":"211","author":"Sorin","year":"2018","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"2025012707411431400_CIT0073","doi-asserted-by":"publisher","first-page":"e222575","DOI":"10.1148\/radiol.222575","article-title":"Beyond breast density: risk measures for breast cancer in multiple imaging modalities","volume":"306","author":"Acciavatti","year":"2023","journal-title":"Radiology"},{"issue":"4","key":"2025012707411431400_CIT0074","doi-asserted-by":"publisher","first-page":"1184","DOI":"10.1109\/TMI.2019.2945514","article-title":"Deep neural networks improve radiologists\u2019 performance in breast cancer screening","volume":"39","author":"Wu","year":"2020","journal-title":"IEEE Trans Med Imaging"},{"key":"2025012707411431400_CIT0075","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.clinimag.2023.05.005","article-title":"A role for breast ultrasound artificial intelligence decision support in the evaluation of small invasive lobular carcinomas","volume":"101","author":"Amir","year":"2023","journal-title":"Clin Imaging"},{"issue":"7","key":"2025012707411431400_CIT0076","doi-asserted-by":"publisher","first-page":"e2423435","DOI":"10.1001\/jamanetworkopen.2024.23435","article-title":"ER-targeted PET for initial staging and suspected recurrence in ER-positive breast cancer","volume":"7","author":"Ulaner","year":"2024","journal-title":"JAMA Netw Open"}],"container-title":["Journal of Breast Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jbi\/article-pdf\/7\/1\/3\/60983823\/wbae082.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbi\/article-pdf\/7\/1\/3\/60983823\/wbae082.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,27]],"date-time":"2025-01-27T07:41:33Z","timestamp":1737963693000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbi\/article\/7\/1\/3\/7918799"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,7]]},"references-count":76,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12,7]]},"published-print":{"date-parts":[[2025,1,25]]}},"URL":"https:\/\/doi.org\/10.1093\/jbi\/wbae082","relation":{},"ISSN":["2631-6110","2631-6129"],"issn-type":[{"value":"2631-6110","type":"print"},{"value":"2631-6129","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,1]]},"published":{"date-parts":[[2024,12,7]]}}}