{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T10:59:00Z","timestamp":1785236340343,"version":"3.55.0"},"reference-count":37,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Breast MRI provides the highest sensitivity for breast cancer detection and is widely used for high-risk screening, assessment of disease extent, treatment monitoring, and evaluation of silicone implant integrity. Despite the central role of fat suppression and tissue-specific signal behavior in determining image quality, the underlying physics principles and mechanisms of failure for these techniques are often underrecognized in clinical practice. This review provides a practical primer on MR signal behavior in commonly used T1 and T2weighted breast MRI sequences and outlines the major techniques used to suppress or separate signals from fat, water, and silicone.<\/jats:p>\n                  <jats:p>We summarize the intrinsic MR properties of fibroglandular tissue, fat, saline and silicone implants, highlighting how differences in relaxation times and resonant frequencies shape image contrast. The operational principles, strengths, and limitations of subtraction, chemical shift selective suppression (CHESS) fat suppression, short tau inversion recovery (STIR), hybrid spectral inversion approaches (SPIR and SPAIR), silicone-specific STIR, and chemical shift encoded (CSE) methods are described, with emphasis on characteristic artifacts and strategies for troubleshooting.<\/jats:p>\n                  <jats:p>By integrating key physics concepts with practical examples, this article aims to equip breast imagers and technologists with a clearer understanding of how signal suppression techniques function, why they fail, and how to optimize MR sequence performance and image quality.<\/jats:p>","DOI":"10.1093\/jbi\/wbag024","type":"journal-article","created":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T11:43:44Z","timestamp":1777376624000},"page":"436-451","source":"Crossref","is-referenced-by-count":0,"title":["Breast MRI Physics Essentials: Signal Behavior, Suppression Approaches, and Appearance of Tissue and Implants"],"prefix":"10.1093","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8455-6270","authenticated-orcid":false,"given":"Leah C","family":"Henze Bancroft","sequence":"first","affiliation":[{"name":"Department of Radiology, University of Wisconsin , Madison, WI ,","place":["USA"]},{"name":"Department of Medical Physics, University of Wisconsin , Madison, WI ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lilian C","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern Medicine , Chicago, IL ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberta M","family":"Strigel","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Wisconsin , Madison, WI ,","place":["USA"]},{"name":"Department of Medical Physics, University of Wisconsin , Madison, WI ,","place":["USA"]},{"name":"Carbone Cancer Center, University of Wisconsin , Madison, WI ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,7,20]]},"reference":[{"issue":"1","key":"2026072806013933300_wbag024-B1","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1002\/jmri.20469","article-title":"Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL","volume":"23","author":"Rakow-Penner","year":"2006","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2026072806013933300_wbag024-B2","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1002\/jmri.22306","article-title":"Longitudinal and multi-echo transverse relaxation times of normal breast tissue at 3 Tesla","volume":"32","author":"Edden","year":"2010","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2026072806013933300_wbag024-B3","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1002\/mrm.1910380422","article-title":"Magnetic resonance properties of ex vivo breast tissue at 1.5 T","volume":"38","author":"Graham","year":"1997","journal-title":"Magn Reson Med"},{"issue":"9","key":"2026072806013933300_wbag024-B4","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1194\/jlr.D800010-JLR200","article-title":"Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 Tesla","volume":"49","author":"Ren","year":"2008","journal-title":"J Lipid Res"},{"issue":"3","key":"2026072806013933300_wbag024-B5","doi-asserted-by":"crossref","first-page":"M625","DOI":"10.1097\/00002480-199407000-00074","article-title":"Magnetic resonance study of virgin and explanted silicone breast prostheses. Can proton relaxation times be used to monitor their biostability?","volume":"40","author":"Dorne","year":"1994","journal-title":"ASAIO J"},{"issue":"1","key":"2026072806013933300_wbag024-B6","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1148\/radiology.187.1.8451442","article-title":"Selective MR imaging of silicone with the three-point Dixon technique","volume":"187","author":"Schneider","year":"1993","journal-title":"Radiology"},{"issue":"5","key":"2026072806013933300_wbag024-B7","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1002\/jmri.22872","article-title":"Water-silicone separated volumetric MR acquisition for rapid assessment of breast implants","volume":"35","author":"Madhuranthakam","year":"2012","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"2026072806013933300_wbag024-B8","doi-asserted-by":"publisher","first-page":"305","DOI":"10.2214\/ajr.162.2.8310916","article-title":"Silicone breast implant rupture: comparison between three-point Dixon and fast spin-echo MR imaging","volume":"162","author":"Gorczyca","year":"1994","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"2026072806013933300_wbag024-B9","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/S1064-9689(21)00132-X","article-title":"MR imaging of breast implants","volume":"2","author":"Gorczyca","year":"1994","journal-title":"Magn Reson Imaging Clin N Am"},{"issue":"1","key":"2026072806013933300_wbag024-B10","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1007\/s00256-020-03564-z","article-title":"Quantitative magnetic resonance imaging: differentiating soft tissue implants and fillers used in cosmetic and reconstructive surgery","volume":"50","author":"Niasme","year":"2021","journal-title":"Skeletal Radiol"},{"key":"2026072806013933300_wbag024-B11","author":"American College of Radiology"},{"key":"2026072806013933300_wbag024-B12","author":"American College of Radiology. MRI and Breast MRI Accredidation: MRI Exam-Specific Parameters: Breast"},{"issue":"3","key":"2026072806013933300_wbag024-B13","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1148\/radiol.2019182947","article-title":"Breast MRI: State of the Art","volume":"292","author":"Mann","year":"2019","journal-title":"Radiology"},{"issue":"9","key":"2026072806013933300_wbag024-B14","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1097\/RLI.0000000000000057","article-title":"A novel approach to contrast-enhanced breast magnetic resonance imaging for screening: high-resolution ultrafast dynamic imaging","volume":"49","author":"Mann","year":"2014","journal-title":"Invest Radiol"},{"issue":"3","key":"2026072806013933300_wbag024-B15","doi-asserted-by":"publisher","first-page":"W183","DOI":"10.2214\/AJR.13.11266","article-title":"Using T2-weighted sequences to more accurately characterize breast masses seen on MRI","volume":"202","author":"Westra","year":"2014","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"2026072806013933300_wbag024-B16","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1088\/0031-9155\/30\/4\/008","article-title":"1H NMR chemical shift selective (CHESS) imaging","volume":"30","author":"Haase","year":"1985","journal-title":"Phys Med Biol"},{"issue":"1","key":"2026072806013933300_wbag024-B17","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1002\/jmri.21895","article-title":"Fat and water magnetic resonance imaging","volume":"31","author":"Bley","year":"2010","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"2026072806013933300_wbag024-B18","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/0730-725x(85)90354-6","article-title":"The short TI inversion recovery sequence\u2013an approach to MR imaging of the abdomen","volume":"3","author":"Bydder","year":"1985","journal-title":"Magn Reson Imaging"},{"issue":"6","key":"2026072806013933300_wbag024-B19","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1097\/00004728-198511000-00004","article-title":"Clinical use of the partial saturation and saturation recovery sequences in MR imaging","volume":"9","author":"Bydder","year":"1985","journal-title":"J Comput Assist Tomogr"},{"issue":"1","key":"2026072806013933300_wbag024-B20","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1148\/rg.341135130","article-title":"Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system","volume":"34","author":"Del Grande","year":"2014","journal-title":"Radiographics"},{"issue":"3","key":"2026072806013933300_wbag024-B21","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1002\/jmri.21492","article-title":"Dixon techniques for water and fat imaging","volume":"28","author":"Ma","year":"2008","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"2026072806013933300_wbag024-B22","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1002\/jmri.10364","article-title":"Fat suppression strategies in enhanced MR imaging of the breast: comparison of SPIR and water excitation sequences","volume":"18","author":"Niitsu","year":"2003","journal-title":"J Magn Reson Imaging"},{"issue":"5","key":"2026072806013933300_wbag024-B23","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1002\/mrm.21537","article-title":"Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery","volume":"59","author":"Balchandani","year":"2008","journal-title":"Magn Reson Med"},{"issue":"1","key":"2026072806013933300_wbag024-B24","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1148\/radiology.191.1.8134602","article-title":"Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences","volume":"191","author":"Foo","year":"1994","journal-title":"Radiology"},{"issue":"5","key":"2026072806013933300_wbag024-B25","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1002\/jmri.1880030505","article-title":"MR imaging of silicone gel-filled breast implants in vivo with a method that visualizes silicone selectively","volume":"3","author":"Mukundan","year":"1993","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2026072806013933300_wbag024-B26","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1148\/radiology.153.1.6089263","article-title":"Simple proton spectroscopic imaging","volume":"153","author":"Dixon","year":"1984","journal-title":"Radiology"},{"issue":"3","key":"2026072806013933300_wbag024-B27","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1002\/mrm.20624","article-title":"Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging","volume":"54","author":"Reeder","year":"2005","journal-title":"Magn Reson Med"},{"issue":"3","key":"2026072806013933300_wbag024-B28","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1002\/jmri.20831","article-title":"Water-fat separation with IDEAL gradient-echo imaging","volume":"25","author":"Reeder","year":"2007","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2026072806013933300_wbag024-B29","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1002\/mrm.20654","article-title":"Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition","volume":"54","author":"Yu","year":"2005","journal-title":"Magn Reson Med"},{"issue":"4","key":"2026072806013933300_wbag024-B30","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1002\/jmri.21090","article-title":"Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation","volume":"26","author":"Yu","year":"2007","journal-title":"J Magn Reson Imaging"},{"issue":"5","key":"2026072806013933300_wbag024-B31","doi-asserted-by":"publisher","first-page":"1122","DOI":"10.1002\/mrm.21737","article-title":"Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling","volume":"60","author":"Yu","year":"2008","journal-title":"Magn Reson Med"},{"issue":"5","key":"2026072806013933300_wbag024-B32","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1002\/jmri.24922","article-title":"Interexamination repeatability and spatial heterogeneity of liver iron and fat quantification using MRI-based multistep adaptive fitting algorithm","volume":"42","author":"Sofue","year":"2015","journal-title":"J Magn Reson Imaging"},{"issue":"5","key":"2026072806013933300_wbag024-B33","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1002\/jmri.24584","article-title":"Quantification of liver iron with MRI: state of the art and remaining challenges","volume":"40","author":"Hernando","year":"2014","journal-title":"J Magn Reson Imaging"},{"issue":"6","key":"2026072806013933300_wbag024-B34","doi-asserted-by":"publisher","first-page":"2186","DOI":"10.1002\/mrm.29590","article-title":"Confounder-corrected T(1) mapping in the liver through simultaneous estimation of T(1), PDFF, R2*, and B1+ in a single breath-hold acquisition","volume":"89","author":"Roberts","year":"2023","journal-title":"Magn Reson Med"},{"issue":"11","key":"2026072806013933300_wbag024-B35","doi-asserted-by":"publisher","first-page":"3253","DOI":"10.1109\/TMI.2022.3180302","article-title":"Hierarchical Multi-Resolution Graph-Cuts for Water-Fat-Silicone Separation in Breast MRI","volume":"41","author":"Stelter","year":"2022","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"2026072806013933300_wbag024-B36","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1002\/jmri.20008","article-title":"Silicone-specific imaging using an inversion-recovery-prepared fast three-point Dixon technique","volume":"19","author":"Ma","year":"2004","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2026072806013933300_wbag024-B37","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1002\/mrm.1167","article-title":"Chemical shift imaging with spectrum modeling","volume":"46","author":"An","year":"2001","journal-title":"Magn Reson Med"}],"container-title":["Journal of Breast Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jbi\/article-pdf\/8\/4\/436\/69565118\/wbag024.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbi\/article-pdf\/8\/4\/436\/69565118\/wbag024.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T10:01:42Z","timestamp":1785232902000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbi\/article\/8\/4\/436\/8738225"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":37,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,7,20]]},"published-print":{"date-parts":[[2026,7,28]]}},"URL":"https:\/\/doi.org\/10.1093\/jbi\/wbag024","relation":{},"ISSN":["2631-6110","2631-6129"],"issn-type":[{"value":"2631-6110","type":"print"},{"value":"2631-6129","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,7]]},"published":{"date-parts":[[2026,7]]}}}