{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T15:28:32Z","timestamp":1779895712496,"version":"3.53.1"},"reference-count":92,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2019,3,1]],"date-time":"2019-03-01T00:00:00Z","timestamp":1551398400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,3,13]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Digital breast tomosynthesis (DBT) is increasingly recognized as a superior breast imaging technology compared with 2D digital mammography (DM) alone. Accumulating data confirm increased sensitivity and specificity in the screening setting, resulting in higher cancer detection rates and lower abnormal interpretation (recall) rates. In the diagnostic environment, DBT simplifies the diagnostic work-up and improves diagnostic accuracy. Initial concern about increased radiation exposure resulting from the DBT acquisition added onto a 2D mammogram has been largely alleviated by the development of synthesized 2D mammography (SM). Continued research is underway to reduce artifacts associated with SM, and improve its comparability to DM. Breast cancers detected with DBT are most often small invasive carcinomas with a preponderance for grade 1 histology and luminal A molecular characteristics. Recent data suggest that higher-grade cancers are also more often node negative when detected with DBT. A meta-analysis of early single-institution studies of the effect of DBT on interval cancers has shown a modest decrease when multiple data sets are combined. Because of the greater conspicuity of lesions on DBT imaging, detection of subtle architectural distortion is increased. Such findings include both spiculated invasive carcinomas and benign etiologies such as radial scars. The diagnostic evaluation of architectural distortion seen only with DBT can pose a challenge. When no sonographic correlate can be identified, DBT-guided biopsy and\/or localization capability is essential. Initial experience with DBT-guided procedures suggests that DBT biopsy equipment may improve the efficiency of percutaneous breast biopsy with less radiation.<\/jats:p>","DOI":"10.1093\/jbi\/wby008","type":"journal-article","created":{"date-parts":[[2019,3,13]],"date-time":"2019-03-13T16:40:59Z","timestamp":1552495259000},"page":"9-22","source":"Crossref","is-referenced-by-count":7,"title":["Digital Breast Tomosynthesis: What Have We Learned?"],"prefix":"10.1093","volume":"1","author":[{"given":"Reni","family":"Butler","sequence":"first","affiliation":[{"name":"Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily F","family":"Conant","sequence":"first","affiliation":[{"name":"University of Pennsylvania Medical Center, Department of Radiology, Philadelphia, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liane","family":"Philpotts","sequence":"first","affiliation":[{"name":"Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2019,3,13]]},"reference":[{"issue":"2","key":"2020071606033855300_CIT0001","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1148\/radiology.205.2.9356620","article-title":"Digital tomosynthesis in breast imaging","volume":"205","author":"Niklason","year":"1997","journal-title":"Radiology"},{"issue":"1","key":"2020071606033855300_CIT0002","doi-asserted-by":"crossref","first-page":"014301","DOI":"10.1118\/1.4770279","article-title":"A review of breast tomosynthesis. Part I. The image acquisition process","volume":"40","author":"Sechopoulos","year":"2013","journal-title":"Med Phys"},{"issue":"1","key":"2020071606033855300_CIT0003","doi-asserted-by":"crossref","first-page":"014302","DOI":"10.1118\/1.4770281","article-title":"A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced appilcations","volume":"40","author":"Sechopoulos","year":"2013","journal-title":"Med Phys"},{"issue":"3","key":"2020071606033855300_CIT0004","doi-asserted-by":"crossref","DOI":"10.1016\/j.rcl.2013.11.013","article-title":"Clinical implementation of digital breast tomosynthesis","volume":"52","author":"Conant","year":"2014","journal-title":"Radiol Clin North Am"},{"issue":"1","key":"2020071606033855300_CIT0005","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1148\/radiol.12121373","article-title":"Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program","volume":"267","author":"Skaane","year":"2013","journal-title":"Radiology"},{"issue":"7","key":"2020071606033855300_CIT0006","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","article-title":"Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study","volume":"14","author":"Ciatto","year":"2013","journal-title":"Lancet Oncol"},{"issue":"6","key":"2020071606033855300_CIT0007","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.2214\/AJR.12.9672","article-title":"Implementation of breast tomosynthesis in a routine screening practice: an observational study","volume":"200","author":"Rose","year":"2013","journal-title":"AJR"},{"issue":"3","key":"2020071606033855300_CIT0008","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1148\/radiol.13130307","article-title":"Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening","volume":"269","author":"Haas","year":"2013","journal-title":"Radiology"},{"issue":"24","key":"2020071606033855300_CIT0009","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1001\/jama.2014.6095","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography","volume":"311","author":"Friedewald","year":"2014","journal-title":"JAMA"},{"issue":"3","key":"2020071606033855300_CIT0010","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1148\/radiol.2015142036","article-title":"Increased cancer detection rate and variations in the recall rate resulting from implementation of 3D digital breast tomosynthesis into a population-based screening program","volume":"278","author":"Sharpe","year":"2016","journal-title":"Radiology"},{"key":"2020071606033855300_CIT0011","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/s00330-014-3409-1","article-title":"Effect of radiologists\u2019 experience in breast cancer detection and localization using digital breast tomosynthesis","volume":"25","author":"Alakhras","year":"2015","journal-title":"Eur Radiol"},{"issue":"11","key":"2020071606033855300_CIT0012","doi-asserted-by":"crossref","first-page":"dju316","DOI":"10.1093\/jnci\/dju316","article-title":"Screening outcomes following implementation of digital breast tomosynthesis in a general-population screening program","volume":"106","author":"McCarthy","year":"2014","journal-title":"J Natl Cancer Inst"},{"issue":"16","key":"2020071606033855300_CIT0013","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1001\/jama.2016.1708","article-title":"Breast cancer screening using tomosynthesis and digital mammography in dense and non-dense breasts","volume":"315","author":"Rafferty","year":"2016","journal-title":"JAMA"},{"key":"2020071606033855300_CIT0014","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1200\/JCO.2015.63.4147","article-title":"Adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts: interim report of a prospective comparative trial","volume":"34","author":"Tagliafico","year":"2016","journal-title":"J Clin Oncol"},{"key":"2020071606033855300_CIT0015","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.ejca.2018.08.029","article-title":"A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2)","volume":"104","author":"Tagliafico","year":"2018","journal-title":"Eur J Cancer"},{"issue":"6","key":"2020071606033855300_CIT0016","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1001\/jamaoncol.2015.5536","article-title":"Effectiveness of digital breast tomosynthesis compared with digital mammography: outcomes analysis from 3 years of breast cancer screening","volume":"2","author":"McDonald","year":"2016","journal-title":"JAMA Oncol"},{"issue":"1","key":"2020071606033855300_CIT0017","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s10549-016-3695-1","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: a cohort study within the PROSPR consortium","volume":"156","author":"Conant","year":"2016","journal-title":"Breast Cancer Res Treat"},{"issue":"3","key":"2020071606033855300_CIT0018","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1148\/radiol.13131391","article-title":"Two-view digital breast tomosynthesis screening with synthetically reconstructed projection images: comparison with digital breast tomosynthesis with full-field digital mammographic images","volume":"271","author":"Skaane","year":"2014","journal-title":"Radiology"},{"issue":"3","key":"2020071606033855300_CIT0019","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1148\/radiol.2016160366","article-title":"Implementation of synthesized two-dimensional mammography in a population-based digital breast tomosynthesis screening program","volume":"281","author":"Zuckerman","year":"2016","journal-title":"Radiology"},{"issue":"4","key":"2020071606033855300_CIT0020","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.clbc.2017.09.012","article-title":"Evidence on synthesized two-dimensional mammography versus digital mammography when using tomosynthesis (three-dimensional mammography) for population breast cancer screening","volume":"18","author":"Houssami","year":"2018","journal-title":"Clin Br Cancer"},{"issue":"3","key":"2020071606033855300_CIT0021","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1148\/radiol.2015142566","article-title":"Accuracy of digital breast tomosynthesis for depicting breast cancer subgroups in a UK retrospective reading study (TOMMY Trial)","volume":"277","author":"Gilbert","year":"2015","journal-title":"Radiology"},{"issue":"8","key":"2020071606033855300_CIT0022","doi-asserted-by":"crossref","first-page":"2538","DOI":"10.1007\/s00330-015-4083-7","article-title":"Comparison between two-dimensional synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for the detection of T1 breast cancer","volume":"26","author":"Choi","year":"2016","journal-title":"Eur Radiol"},{"key":"2020071606033855300_CIT0023","doi-asserted-by":"crossref","first-page":"222","DOI":"10.2214\/AJR.16.17476","article-title":"Imaging with synthesized 2D mammography: differences, advantages, and pitfalls compared with digital mammography","volume":"209","author":"Zuckerman","year":"2017","journal-title":"AJR"},{"key":"2020071606033855300_CIT0024","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.ejrad.2018.08.004","article-title":"A comparison of full-field digital mammograms versus 2D synthesized mammograms for detection of microcalcifications on screening","volume":"107","author":"Wahab","year":"2018","journal-title":"Eur J Radiol"},{"key":"2020071606033855300_CIT0025","article-title":"D\u2019Orsi CJ, Sickles EA, Mendelson EB, Morris EA, et al. ACR BI-RADS\u00ae Atlas, Breast Imaging Reporting and Data System. Reston, VA: American College of Radiology; 2013"},{"issue":"4","key":"2020071606033855300_CIT0026","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.acra.2009.11.011","article-title":"Time to diagnosis and performance levels during repeat interpretations of digital breast tomosynthesis: preliminary observations","volume":"17","author":"Zuley","year":"2010","journal-title":"Acad Radiol"},{"issue":"1","key":"2020071606033855300_CIT0027","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1148\/radiol.13130765","article-title":"Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations","volume":"270","author":"Dang","year":"2014","journal-title":"Radiology"},{"key":"2020071606033855300_CIT0028","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5690-x","article-title":"A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance indicators from the To-Be trial","author":"Aase","year":"2018","journal-title":"Eur Radiol"},{"issue":"6","key":"2020071606033855300_CIT0029","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1016\/j.breast.2015.08.012","article-title":"Radiologists\u2019 interpretive efficiency and variability in true- and false-positive detection when screen-reading with tomosynthesis (3D-mammography) relative to standard mammography in population screening","volume":"24","author":"Svahn","year":"2015","journal-title":"Breast"},{"issue":"5","key":"2020071606033855300_CIT0030","doi-asserted-by":"crossref","first-page":"957","DOI":"10.2214\/AJR.17.19350","article-title":"The effect of digital breast tomosynthesis adoption on facility-level breast cancer screening volume","volume":"211","author":"Lee","year":"2018","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"2020071606033855300_CIT0031","doi-asserted-by":"crossref","first-page":"291","DOI":"10.2214\/AJR.12.8881","article-title":"Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting","volume":"200","author":"Brandt","year":"2013","journal-title":"AJR"},{"issue":"1","key":"2020071606033855300_CIT0032","doi-asserted-by":"crossref","first-page":"226","DOI":"10.2214\/AJR.11.8202","article-title":"Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening","volume":"200","author":"Waldherr","year":"2013","journal-title":"AJR"},{"issue":"1","key":"2020071606033855300_CIT0033","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1148\/radiol.11101763","article-title":"Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization","volume":"262","author":"Noroozian","year":"2012","journal-title":"Radiology"},{"issue":"3","key":"2020071606033855300_CIT0034","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1007\/s00330-011-2305-1","article-title":"One-to-one comparison between digital spot compression view and digital breast tomosynthesis","volume":"22","author":"Tagliafico","year":"2012","journal-title":"Eur Radiol"},{"issue":"1","key":"2020071606033855300_CIT0035","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1148\/radiol.12120552","article-title":"Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions","volume":"266","author":"Zuley","year":"2013","journal-title":"Radiology"},{"key":"2020071606033855300_CIT0036","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5596-7","article-title":"Comparison of diagnostic metrics with digital 2D versus tomosynthesis mammography in the diagnostic setting","author":"Bahl","year":"2018","journal-title":"Eur Radiol"},{"key":"2020071606033855300_CIT0037","doi-asserted-by":"crossref","first-page":"445","DOI":"10.2214\/AJR.17.19023","article-title":"Screening mammography findings from one standard projection only in the era of full-field digital mammography and digital breast tomosynthesis","volume":"211","author":"Cohen","year":"2018","journal-title":"AJR"},{"issue":"2","key":"2020071606033855300_CIT0038","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1148\/radiol.14140317","article-title":"Changes in recall type and patient treatment following implementation of screening digital breast tomosynthesis","volume":"274","author":"Lourenco","year":"2015","journal-title":"Radiology"},{"key":"2020071606033855300_CIT0039","unstructured":"Butler\n              RS\n            , KalraV, CrenshawJ, et al\n          Tomosynthesis in diagnostic mammography: continued change after 4 years. RSNA Annual Meeting 2015. Chicago, IL."},{"key":"2020071606033855300_CIT0040","unstructured":"Butler\n              RS\n            , HuiA, StaibLH, et al\n          Downstream effect of tomosynthesis screening: a more efficient diagnostic work-up of screening recalls. RSNA Annual Meeting 2012.Chicago, IL."},{"issue":"5","key":"2020071606033855300_CIT0041","doi-asserted-by":"crossref","first-page":"2431","DOI":"10.1118\/1.3694105","article-title":"Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: a 4AFC human observer study","volume":"39","author":"Timberg","year":"2012","journal-title":"Med Phys"},{"issue":"2","key":"2020071606033855300_CIT0042","doi-asserted-by":"crossref","first-page":"320","DOI":"10.2214\/AJR.10.4656","article-title":"Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison","volume":"196","author":"Spangler","year":"2011","journal-title":"AJR"},{"issue":"6","key":"2020071606033855300_CIT0043","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1111\/j.1524-4741.2011.01152.x","article-title":"Calcifications in the breast and digital breast tomosynthesis","volume":"17","author":"Kopans","year":"2011","journal-title":"Breast J"},{"key":"2020071606033855300_CIT0044","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5585-x","article-title":"Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications","author":"Choi","year":"2018","journal-title":"Eur Radiol"},{"key":"2020071606033855300_CIT0045","doi-asserted-by":"publisher","first-page":"181180","DOI":"10.1148\/radiol.2018181180","article-title":"Microcalcifications detected at screening mammography: synthetic mammography and digital breast tomosynthesis versus digital mammography","author":"Lai","year":"2018","journal-title":"Radiology"},{"key":"2020071606033855300_CIT0046","doi-asserted-by":"publisher","first-page":"S1076-6332(18)30310-6","DOI":"10.1016\/j.acra.2018.05.026","article-title":"Comparison of resource utilization and clinical outcomes following screening with digital breast tomosynthesis versus digital mammography: findings from a learning health system","author":"Alsheik","year":"2018","journal-title":"Acad Radiol"},{"issue":"1","key":"2020071606033855300_CIT0047","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1148\/radiol.2018171159","article-title":"Outcome of architectural distortion detected only at breast tomosynthesis versus 2D mammography","volume":"288","author":"Alshafeiy","year":"2018","journal-title":"Radiology"},{"issue":"5","key":"2020071606033855300_CIT0048","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.2214\/AJR.17.17979","article-title":"Pathologic outcomes of architectural distortion on digital 2D versus tomosynthesis mammography","volume":"209","author":"Bahl","year":"2017","journal-title":"AJR"},{"issue":"1","key":"2020071606033855300_CIT0049","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s00330-017-4968-8","article-title":"Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion","volume":"28","author":"Dibble","year":"2018","journal-title":"Eur Radiol"},{"issue":"1","key":"2020071606033855300_CIT0050","doi-asserted-by":"crossref","first-page":"216","DOI":"10.2214\/AJR.13.11047","article-title":"Detection of mammographically occult architectural distortion on digital breast tomosynthesis screening: initial clinical experience","volume":"203","author":"Partyka","year":"2014","journal-title":"AJR"},{"key":"2020071606033855300_CIT0051","article-title":"Tomosynthesis in diagnostic mammography. In: Breast Tomosynthesis, Elsevier; 2016:39\u201355","author":"Butler"},{"key":"2020071606033855300_CIT0052","unstructured":"Butler\n              RS\n            , O\u2019ConnellSH, RaghuMD, et al\n          The radial scar dilemma: incidence and surgical upgrade rates with tomosynthesis. RSNA Annual Meeting 2017.Chicago, IL."},{"key":"2020071606033855300_CIT0053","volume-title":"Teaching atlas of mammography","author":"Tabar","year":"1985"},{"issue":"2","key":"2020071606033855300_CIT0054","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.ejrad.2006.08.003","article-title":"Are the criteria of Tabar and Dean still relevant to radial scar","volume":"60","author":"Boute","year":"2006","journal-title":"Eur J Radiol"},{"issue":"3","key":"2020071606033855300_CIT0055","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1148\/radiology.195.3.7753984","article-title":"Mammographic lesions suggestive of radial scars: microscopic findings in 40 cases","volume":"195","author":"Frouge","year":"1995","journal-title":"Radiology"},{"issue":"3","key":"2020071606033855300_CIT0056","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1148\/radiology.187.3.8388568","article-title":"Radial scars of the breast: review of 38 consecutive mammographic diagnoses","volume":"187","author":"Ciatto","year":"1993","journal-title":"Radiology"},{"issue":"3","key":"2020071606033855300_CIT0057","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1148\/radiology.176.3.2389032","article-title":"Radial sclerosing lesion of the breast: mammographic features","volume":"176","author":"Adler","year":"1990","journal-title":"Radiology"},{"issue":"2","key":"2020071606033855300_CIT0058","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1148\/radiology.183.2.1561353","article-title":"Radial scar with microcalcifications: radiologic-pathologic correlation","volume":"183","author":"Orel","year":"1992","journal-title":"Radiology"},{"issue":"3","key":"2020071606033855300_CIT0059","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1111\/j.1365-2559.1993.tb01194.x","article-title":"Carcinoma and atypical hyperplasia in radial scars and complex sclerosing lesions: importance of lesion size and patient age","volume":"23","author":"Sloane","year":"1993","journal-title":"Histopathology"},{"issue":"5","key":"2020071606033855300_CIT0060","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1111\/j.1365-2559.2007.02660.x","article-title":"Radial scars\/complex sclerosing lesions and malignancy in a screening programme: incidence and histological features revisited","volume":"50","author":"Doyle","year":"2007","journal-title":"Histopathology"},{"issue":"2","key":"2020071606033855300_CIT0061","doi-asserted-by":"crossref","first-page":"W132","DOI":"10.2214\/AJR.11.7799","article-title":"Multidisciplinary considerations in the management of high-risk breast lesions","volume":"198","author":"Krishnamurthy","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"2020071606033855300_CIT0062","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.humpath.2015.06.028","article-title":"Pathologic findings of follow-up surgical excision for radial scar on breast core needle biopsy","volume":"48","author":"Li","year":"2016","journal-title":"Hum Pathol"},{"issue":"2","key":"2020071606033855300_CIT0063","first-page":"72","article-title":"Management of radial scars found at percutaneous breast biopsy","volume":"57","author":"Becker","year":"2006","journal-title":"Can Assoc Radiol J"},{"issue":"5","key":"2020071606033855300_CIT0064","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.2214\/ajr.179.5.1791179","article-title":"Percutaneous core needle biopsy of radial scars of the breast: when is excision necessary","volume":"179","author":"Brenner","year":"2002","journal-title":"AJR"},{"issue":"3","key":"2020071606033855300_CIT0065","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1136\/jcp.2006.037069","article-title":"Radial scar lesions of the breast diagnosed by needle core biopsy: analysis of cases containing occult malignancy","volume":"60","author":"Douglas-Jones","year":"2007","journal-title":"J Clin Pathol"},{"issue":"2","key":"2020071606033855300_CIT0066","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/cncr.11070","article-title":"Fourteen-gauge needle core biopsy of mammographically evident radial scars: is excision necessary","volume":"97","author":"Cawson","year":"2003","journal-title":"Cancer"},{"issue":"6","key":"2020071606033855300_CIT0067","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1097\/PAS.0000000000000393","article-title":"Radial scar at image-guided needle biopsy: is excision necessary","volume":"39","author":"Conlon","year":"2015","journal-title":"Am J Surg Pathol"},{"issue":"2","key":"2020071606033855300_CIT0068","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s10549-008-0119-x","article-title":"Management of radial sclerosing lesions of the breast diagnosed using percutaneous vacuum-assisted core needle biopsy: recommendations for excision based on seven years\u2019 of experience at a single institution","volume":"127","author":"Resetkova","year":"2011","journal-title":"Breast Cancer Res Treat"},{"issue":"3","key":"2020071606033855300_CIT0069","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1148\/radiology.216.3.r00se31831","article-title":"Uncommon high-risk lesions of the breast diagnosed at stereotactic core-needle biopsy: clinical importance","volume":"216","author":"Philpotts","year":"2000","journal-title":"Radiology"},{"issue":"1","key":"2020071606033855300_CIT0070","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1148\/radiol.2016151999","article-title":"Tomosynthesis in the diagnostic setting: changing rates of BI-RADS final assessment over time","volume":"281","author":"Raghu","year":"2016","journal-title":"Radiology"},{"issue":"1","key":"2020071606033855300_CIT0071","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1148\/radiol.2016161174","article-title":"National performance benchmarks for modern screening digital mammography: update from the Breast Cancer Surveillance Consortium","volume":"283","author":"Lehman","year":"2017","journal-title":"Radiology"},{"issue":"2","key":"2020071606033855300_CIT0072","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1148\/radiol.12121216","article-title":"Diagnostic mammography: identifying minimally acceptable interpretive performance criteria","volume":"267","author":"Carney","year":"2013","journal-title":"Radiology"},{"issue":"3","key":"2020071606033855300_CIT0073","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1148\/radiol.2353040738","article-title":"Performance benchmarks for diagnostic mammography","volume":"235","author":"Sickles","year":"2005","journal-title":"Radiology"},{"issue":"9","key":"2020071606033855300_CIT0074","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/j.crad.2016.04.004","article-title":"Digital breast tomosynthesis as an adjunct to digital mammography for detecting and characterising invasive lobular cancers: a multi-reader study","volume":"71","author":"Mariscotti","year":"2016","journal-title":"Clin Radiol"},{"issue":"1","key":"2020071606033855300_CIT0075","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1148\/radiol.2017171148","article-title":"Breast cancer characteristics associated with 2D digital mammography versus digital breast tomosynthesis for screening-detected and interval cancers","volume":"287","author":"Bahl","year":"2018","journal-title":"Radiology"},{"issue":"2","key":"2020071606033855300_CIT0076","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1007\/s10549-018-4756-4","article-title":"Comparison of breast cancers detected in the Verona screening program following transition to digital breast tomosynthesis screening with cancers detected at digital mammography screening","volume":"170","author":"Caumo","year":"2018","journal-title":"Breast Cancer Res Treat"},{"key":"2020071606033855300_CIT0077","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/s10549-017-4298-1","article-title":"Benefit of adding digital breast tomosynthesis to digital mammography for breast cancer screening focused on cancer charachteristics","volume":"164","author":"Yun","year":"2017","journal-title":"Breast Cancer Res Treat"},{"issue":"3","key":"2020071606033855300_CIT0078","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1148\/radiol.2018171361","article-title":"Digital breast tomosynthesis and synthetic 2D mammography versus digital mammography: evaluation in a population-based screening program","volume":"287","author":"Hofvind","year":"2018","journal-title":"Radiology"},{"issue":"6","key":"2020071606033855300_CIT0079","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.2214\/AJR.17.18195","article-title":"Biologic profiles of invasive breast cancers detected only with digital breast tomosynthesis","volume":"209","author":"Kim","year":"2017","journal-title":"AJR"},{"issue":"6","key":"2020071606033855300_CIT0080","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1111\/tbj.12649","article-title":"Breast cancers found with digital breast tomosynthesis","volume":"22","author":"Wang","year":"2016","journal-title":"Breast J"},{"issue":"2","key":"2020071606033855300_CIT0081","doi-asserted-by":"crossref","first-page":"325","DOI":"10.2214\/ajr.172.2.9930776","article-title":"Sonographic evaluation of infiltrating lobular carcinoma","volume":"172","author":"Butler","year":"1999","journal-title":"AJR"},{"key":"2020071606033855300_CIT0082","unstructured":"Etesami\n              M\n            , GiwercM, HarigopalM, et al\n          Cancer detection with digital breast tomosynthesis (DBT) compared with conventional digital mammography in routine breast cancer screening. RSNA Annual Meeting 2017.Chicago, IL."},{"key":"2020071606033855300_CIT0083","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.breast.2018.01.002","article-title":"Interval breast cancers in the \u2018screening with tomosynthesis or standard mammography\u2019 (STORM) population-based trial","volume":"38","author":"Houssami","year":"2018","journal-title":"Breast"},{"key":"2020071606033855300_CIT0084"},{"key":"2020071606033855300_CIT0085"},{"key":"2020071606033855300_CIT0086","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1111\/tbj.12446","article-title":"Suspicious findings at digital breast tomosynthesis occult to conventional digital mammography: imaging features and pathological findings","volume":"221","author":"Ray","year":"2015","journal-title":"Breast J"},{"issue":"6","key":"2020071606033855300_CIT0087","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1007\/s00330-015-4009-4","article-title":"Tomosynthesis-guided vacuum-assisted breast biopsy: a feasibility study","volume":"26","author":"Waldherr","year":"2016","journal-title":"Eur Radiol"},{"issue":"3","key":"2020071606033855300_CIT0088","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1148\/radiol.14141397","article-title":"Digital breast tomosynthesis-guided vacuum-assisted breast biopsy: initial experiences and comparison with prone stereotactic vacuum-assisted biopsy","volume":"274","author":"Schrading","year":"2015","journal-title":"Radiology"},{"key":"2020071606033855300_CIT0089","doi-asserted-by":"crossref","first-page":"28","DOI":"10.4103\/jcis.JCIS_10_18","article-title":"Tomosynthesis-guided core biopsy of the breast: why and how to use it","volume":"8","author":"Shin","year":"2018","journal-title":"J Clin Imaging Sci"},{"key":"2020071606033855300_CIT0090","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.clinimag.2017.08.002","article-title":"Digital breast tomosynthesis vacuum assisted biopsy for tomosynthesis-detected sonographically occult lesions","volume":"47","author":"Ariaratnam","year":"2018","journal-title":"Clin Imaging"},{"key":"2020071606033855300_CIT0091","unstructured":"Amir\n              T\n            , Barufaldi B, Zuckerman SP, et al\n          Comparison between radiation dose of 2D digital versus digital tomosynthesis guided stereotactic breast biopsies: tomosynthesis wins! Educational exhibit. RSNA Annual Meeting 2018.Chicago, IL."},{"key":"2020071606033855300_CIT0092","doi-asserted-by":"crossref","DOI":"10.1111\/tbj.13070","article-title":"The role of tomosynthesis in intraoperative specimen evaluation","author":"Polat","year":"2018","journal-title":"Breast J"}],"container-title":["Journal of Breast Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/jbi\/article-pdf\/1\/1\/9\/33501719\/wby008.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/jbi\/article-pdf\/1\/1\/9\/33501719\/wby008.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,16]],"date-time":"2020-07-16T10:25:46Z","timestamp":1594895146000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbi\/article\/1\/1\/9\/5379166"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":92,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,3,13]]},"published-print":{"date-parts":[[2019,3,13]]}},"URL":"https:\/\/doi.org\/10.1093\/jbi\/wby008","relation":{},"ISSN":["2631-6110","2631-6129"],"issn-type":[{"value":"2631-6110","type":"print"},{"value":"2631-6129","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,3]]},"published":{"date-parts":[[2019,3]]}}}