{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T02:01:04Z","timestamp":1793325664378,"version":"4.5.0"},"reference-count":35,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2018,8,9]],"date-time":"2018-08-09T00:00:00Z","timestamp":1533772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/about_us\/legal\/notices"}],"funder":[{"name":"Cancer Institute NSW (CINSW) Early Career Fellowship","award":["14\/ECF\/1\u201306"],"award-info":[{"award-number":["14\/ECF\/1\u201306"]}]},{"DOI":"10.13039\/501100001026","name":"National Breast Cancer Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001026","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Breast Cancer Research Leadership Fellowship"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,9,1]]},"DOI":"10.1093\/jnci\/djy121","type":"journal-article","created":{"date-parts":[[2018,6,15]],"date-time":"2018-06-15T07:07:37Z","timestamp":1529046457000},"page":"942-949","source":"Crossref","is-referenced-by-count":237,"title":["Breast Cancer Screening Using Tomosynthesis or Mammography: A Meta-analysis of Cancer Detection and Recall"],"prefix":"10.1093","volume":"110","author":[{"given":"M Luke","family":"Marinovich","sequence":"first","affiliation":[{"name":"Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kylie E","family":"Hunter","sequence":"additional","affiliation":[{"name":"Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia"},{"name":"NHMRC Clinical Trials Centre, Camperdown, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petra","family":"Macaskill","sequence":"additional","affiliation":[{"name":"Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nehmat","family":"Houssami","sequence":"additional","affiliation":[{"name":"Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2018,8,9]]},"reference":[{"issue":"24","key":"key\n\t\t\t\t20180913195333_djy121-B1","doi-asserted-by":"crossref","first-page":"2353","DOI":"10.1056\/NEJMsr1504363","article-title":"Breast-cancer screening-viewpoint of the IARC Working Group","volume":"372","author":"Lauby-Secretan","year":"2015","journal-title":"N Engl J Med"},{"issue":"9855","key":"key\n\t\t\t\t20180913195333_djy121-B2","doi-asserted-by":"crossref","first-page":"1778","DOI":"10.1016\/S0140-6736(12)61611-0","article-title":"The benefits and harms of breast cancer screening: An independent review","volume":"380","author":"Marmot","year":"2012","journal-title":"Lancet"},{"issue":"4","key":"key\n\t\t\t\t20180913195333_djy121-B3","doi-asserted-by":"crossref","first-page":"256","DOI":"10.7326\/M15-0970","article-title":"Harms of breast cancer screening: Systematic review to update the 2009 U.S. Preventive services task force recommendation","volume":"164","author":"Nelson","year":"2016","journal-title":"Ann Intern Med"},{"issue":"6","key":"key\n\t\t\t\t20180913195333_djy121-B4","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1001\/jamaoncol.2015.5569","article-title":"Digital breast tomosynthesis: A brave new world of mammography screening","volume":"2","author":"Houssami","year":"2016","journal-title":"JAMA Oncol"},{"issue":"2","key":"key\n\t\t\t\t20180913195333_djy121-B5","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.crad.2015.11.008","article-title":"Digital breast tomosynthesis (DBT): A review of the evidence for use as a screening tool","volume":"71","author":"Gilbert","year":"2016","journal-title":"Clin Radiol"},{"issue":"3","key":"key\n\t\t\t\t20180913195333_djy121-B6","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.rcl.2013.11.013","article-title":"Clinical implementation of digital breast tomosynthesis","volume":"52","author":"Conant","year":"2014","journal-title":"Radiol Clin North Am"},{"issue":"2","key":"key\n\t\t\t\t20180913195333_djy121-B7","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.breast.2013.01.017","article-title":"Overview of the evidence on digital breast tomosynthesis in breast cancer detection","volume":"22","author":"Houssami","year":"2013","journal-title":"Breast"},{"issue":"01","key":"key\n\t\t\t\t20180913195333_djy121-B8","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.breast.2016.09.008","article-title":"Rapid review: Estimates of incremental breast cancer detection from tomosynthesis (3D mammography) screening in women with dense breasts","volume":"30(","author":"Houssami","year":"2016","journal-title":"Breast"},{"key":"key\n\t\t\t\t20180913195333_djy121-B9","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.breast.2016.01.002","article-title":"Systematic review of 3D mammography for breast cancer screening","volume":"27","author":"Hodgson","year":"2016","journal-title":"Breast"},{"issue":"3","key":"key\n\t\t\t\t20180913195333_djy121-B10","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/s10549-017-4298-1","article-title":"Benefit of adding digital breast tomosynthesis to digital mammography for breast cancer screening focused on cancer characteristics: A meta-analysis","volume":"164","author":"Yun","year":"2017","journal-title":"Breast Cancer Res Treat"},{"key":"key\n\t\t\t\t20180913195333_djy121-B11","volume-title":"Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy","author":"Macaskill","year":"2010"},{"issue":"9","key":"key\n\t\t\t\t20180913195333_djy121-B12","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1016\/j.jclinepi.2005.01.016","article-title":"The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed","volume":"58","author":"Deeks","year":"2005","journal-title":"J Clin Epidemiol"},{"key":"key\n\t\t\t\t20180913195333_djy121-B13","author":"D'Orsi","year":"2013"},{"issue":"8","key":"key\n\t\t\t\t20180913195333_djy121-B14","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"Quadas-2: A revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"key\n\t\t\t\t20180913195333_djy121-B15","author":"Higgins"},{"issue":"1","key":"key\n\t\t\t\t20180913195333_djy121-B16","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1148\/radiol.2017162674","article-title":"Clinical performance of synthesized two-dimensional mammography combined with tomosynthesis in a large screening population","volume":"283","author":"Aujero","year":"2017","journal-title":"Radiology"},{"issue":"8","key":"key\n\t\t\t\t20180913195333_djy121-B17","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1016\/S1470-2045(16)30101-2","article-title":"Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): A population-based prospective study","volume":"17","author":"Bernardi","year":"2016","journal-title":"Lancet Oncol"},{"issue":"7","key":"key\n\t\t\t\t20180913195333_djy121-B18","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","article-title":"Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): A prospective comparison study","volume":"14","author":"Ciatto","year":"2013","journal-title":"Lancet Oncol"},{"issue":"1","key":"key\n\t\t\t\t20180913195333_djy121-B19","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s10549-016-3695-1","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography compared to digital mammography alone: A cohort study within the PROSPR Consortium","volume":"156","author":"Conant","year":"2016","journal-title":"Breast Cancer Res Treat"},{"issue":"1","key":"key\n\t\t\t\t20180913195333_djy121-B20","doi-asserted-by":"crossref","first-page":"9.","DOI":"10.4103\/2156-7514.127838","article-title":"Initial experience with combination digital breast tomosynthesis plus full field digital mammography or full field digital mammography alone in the screening environment","volume":"4","author":"Destounis","year":"2014","journal-title":"J Clin Imaging Sci"},{"issue":"1","key":"key\n\t\t\t\t20180913195333_djy121-B21","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1148\/radiol.14131319","article-title":"Early clinical experience with digital breast tomosynthesis for screening mammography","volume":"274","author":"Durand","year":"2015","journal-title":"Radiology"},{"issue":"24","key":"key\n\t\t\t\t20180913195333_djy121-B22","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1001\/jama.2014.6095","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography","volume":"311","author":"Friedewald","year":"2014","journal-title":"J Am Med Assoc"},{"issue":"3","key":"key\n\t\t\t\t20180913195333_djy121-B23","doi-asserted-by":"crossref","first-page":"687","DOI":"10.2214\/AJR.14.12642","article-title":"Clinical performance metrics of 3D digital breast tomosynthesis compared with 2D digital mammography for breast cancer screening in community practice","volume":"203","author":"Greenberg","year":"2014","journal-title":"Am J Roentgenol"},{"issue":"3","key":"key\n\t\t\t\t20180913195333_djy121-B24","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1148\/radiol.13130307","article-title":"Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening","volume":"269","author":"Haas","year":"2013","journal-title":"Radiology"},{"issue":"1","key":"key\n\t\t\t\t20180913195333_djy121-B25","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1007\/s00330-015-3803-3","article-title":"Performance of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: Results from the Malmo Breast Tomosynthesis Screening Trial, a population-based study","volume":"26","author":"Lang","year":"2016","journal-title":"Eur Radiol"},{"issue":"2","key":"key\n\t\t\t\t20180913195333_djy121-B26","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1148\/radiol.14140317","article-title":"Changes in recall type and patient treatment following implementation of screening digital breast tomosynthesis","volume":"274","author":"Lourenco","year":"2015","journal-title":"Radiology"},{"issue":"11","key":"key\n\t\t\t\t20180913195333_djy121-B27","doi-asserted-by":"crossref","first-page":"dju316.","DOI":"10.1093\/jnci\/dju316","article-title":"Screening outcomes following implementation of digital breast tomosynthesis in a general-population screening program","volume":"106","author":"McCarthy","year":"2014","journal-title":"J Natl Cancer Inst"},{"issue":"3","key":"key\n\t\t\t\t20180913195333_djy121-B28","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.acra.2016.10.001","article-title":"Impact of the addition of digital breast tomosynthesis (DBT) to standard 2D digital screening mammography on the rates of patient recall, cancer detection, and recommendations for short-term follow-up","volume":"24","author":"Powell","year":"2017","journal-title":"Acad Radiol"},{"issue":"6","key":"key\n\t\t\t\t20180913195333_djy121-B29","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.2214\/AJR.12.9672","article-title":"Implementation of breast tomosynthesis in a routine screening practice: An observational study","volume":"200","author":"Rose","year":"2013","journal-title":"Am J Roentgenol"},{"issue":"3","key":"key\n\t\t\t\t20180913195333_djy121-B30","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1148\/radiol.2015142036","article-title":"Increased cancer detection rate and variations in the recall rate resulting from implementation of 3D digital breast tomosynthesis into a population-based screening program","volume":"278","author":"Sharpe","year":"2016","journal-title":"Radiology"},{"issue":"8","key":"key\n\t\t\t\t20180913195333_djy121-B31","doi-asserted-by":"crossref","first-page":"2061","DOI":"10.1007\/s00330-013-2820-3","article-title":"Prospective trial comparing full-field digital mammography (FFDM) versus combined FFDM and tomosynthesis in a population-based screening programme using independent double reading with arbitration","volume":"23","author":"Skaane","year":"2013","journal-title":"Eur Radiol"},{"issue":"1","key":"key\n\t\t\t\t20180913195333_djy121-B32","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.clinimag.2015.10.001","article-title":"2D mammography, digital breast tomosynthesis, and ultrasound: Which should be used for the different breast densities in breast cancer screening?","volume":"40","author":"Starikov","year":"2015","journal-title":"Clin Imaging"},{"issue":"10","key":"key\n\t\t\t\t20180913195333_djy121-B33","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.1016\/j.ejca.2014.03.017","article-title":"Breast screening using 2D mammography or integrating digital breast tomosynthesis (3D mammography) for single-reading or double-reading\u2014evidence to guide future screening strategies","volume":"50","author":"Houssami","year":"2014","journal-title":"Eur J Cancer"},{"issue":"6","key":"key\n\t\t\t\t20180913195333_djy121-B34","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1001\/jamaoncol.2015.5536","article-title":"Effectiveness of digital breast tomosynthesis compared with digital mammography: Outcomes analysis from 3 years of breast cancer screening","volume":"2","author":"McDonald","year":"2016","journal-title":"JAMA Oncol"},{"issue":"4","key":"key\n\t\t\t\t20180913195333_djy121-B35","doi-asserted-by":"crossref","first-page":"869","DOI":"10.21037\/tcr.2017.06.39","article-title":"Effectiveness of digital breast tomosynthesis (3D mammography) in population breast cancer screening: A protocol for a collaborative individual participant data (IPD) meta-analysis","volume":"6","author":"Houssami","year":"2017","journal-title":"Transl Cancer Res"}],"container-title":["JNCI: Journal of the National Cancer Institute"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/jnci\/article-pdf\/110\/9\/942\/25722330\/djy121.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,19]],"date-time":"2019-10-19T09:56:12Z","timestamp":1571478972000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jnci\/article\/110\/9\/942\/5068658"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,9]]},"references-count":35,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2018,8,9]]},"published-print":{"date-parts":[[2018,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/jnci\/djy121","relation":{},"ISSN":["0027-8874","1460-2105"],"issn-type":[{"value":"0027-8874","type":"print"},{"value":"1460-2105","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2018,9]]},"published":{"date-parts":[[2018,8,9]]}}}