{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T10:06:44Z","timestamp":1779790004480,"version":"3.53.1"},"reference-count":20,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T00:00:00Z","timestamp":1776902400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,26]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>This study evaluated the safety, feasibility and efficacy of endovascular pulmonary arterial fiducial marker (EVFM) placement for image-guided particle therapy using proton or carbon-ion beams in patients with primary or metastatic lung cancer. Methods: A 5F catheter system was used to insert platinum coil markers via the right femoral vein into a distal pulmonary artery near the tumor under fluoroscopic guidance. Tumor-to-marker distances, marker migration and therapy completion were assessed. From July 2016 to January 2019, 54 patients (38 men, 16 women; median age, 71\u00a0years) with 46 primary and 8 metastatic lung tumors underwent marker placement. Tumors were located in 33 right and 21 left lobes, with a median diameter of 22\u00a0mm. Ten patients received proton therapy, and 44 received carbon-ion therapy. There were no marker placement related complications. Transient arrhythmias occurred only when the guide wire passed through the right ventricle. Tumor-to-marker distances ranged from 0\u201317\u00a0mm (median, 5\u00a0mm). Migration during irradiation was minimal (median, 0\u00a0mm); one case showed a 4-mm shift due to lung deformation, not marker displacement. All patients completed scheduled therapy without marker migration. EVFM placement is a feasible and safe alternative to computed tomography- or bronchoscopy-guided fiducial marker placement, offering accurate localization with minimal complications or marker migration in particle therapy for lung cancer.<\/jats:p>","DOI":"10.1093\/jrr\/rrag022","type":"journal-article","created":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T12:52:19Z","timestamp":1773233539000},"page":"430-435","source":"Crossref","is-referenced-by-count":0,"title":["Endovascular pulmonary arterial fiducial marker placement for particle radiotherapy using proton or carbon-ion beams for lung cancer"],"prefix":"10.1093","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-1198-5554","authenticated-orcid":false,"given":"Kazuki","family":"Terashima","sequence":"first","affiliation":[{"name":"Department of Radiology, Hyogo Ion Beam Medical Center , 1-2-1 Kouto, Shingu-cho, Tatsuno, Hyogo 679-5165 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoyuki","family":"Gentsu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kobe University Graduate School of Medicine , 7-5-2, Kusunoki-cho, Chuouku, Kobe, Hyogo 650-0017 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daiki","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hyogo Ion Beam Medical Center , 1-2-1 Kouto, Shingu-cho, Tatsuno, Hyogo 679-5165 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiro","family":"Matsuo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hyogo Ion Beam Medical Center , 1-2-1 Kouto, Shingu-cho, Tatsuno, Hyogo 679-5165 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasue","family":"Niwa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hyogo Ion Beam Medical Center , 1-2-1 Kouto, Shingu-cho, Tatsuno, Hyogo 679-5165 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4465-4300","authenticated-orcid":false,"given":"Yusuke","family":"Demizu","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, Hyogo Ion Beam Medical Center Kobe Proton Center , 1-6-8, Minamicho, Minatozima, Chuouku, Kobe, Hyogo 650-0047 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4947-7665","authenticated-orcid":false,"given":"Sunao","family":"Tokumaru","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hyogo Ion Beam Medical Center , 1-2-1 Kouto, Shingu-cho, Tatsuno, Hyogo 679-5165 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoaki","family":"Okimoto","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hyogo Ion Beam Medical Center , 1-2-1 Kouto, Shingu-cho, Tatsuno, Hyogo 679-5165 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,4,23]]},"reference":[{"key":"2026052605522649500_ref1","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s13014-016-0693-8","article-title":"A critical review of recent developments in radiotherapy for non-small cell lung cancer","volume":"11","author":"Baker","year":"2016","journal-title":"Radiat Oncol"},{"key":"2026052605522649500_ref2","doi-asserted-by":"publisher","first-page":"e28","DOI":"10.1016\/S1470-2045(12)70510-7","article-title":"Stereotactic body radiotherapy for oligometastases","volume":"14","author":"Tree","year":"2013","journal-title":"Lancet Oncol"},{"key":"2026052605522649500_ref3","doi-asserted-by":"publisher","first-page":"46","DOI":"10.4329\/wjr.v11.i3.46","article-title":"Progress in image-guided radiotherapy for the treatment of non-small cell lung cancer","volume":"11","author":"Ren","year":"2019","journal-title":"World J Radiol"},{"key":"2026052605522649500_ref4","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1038\/nrclinonc.2017.30","article-title":"Charged-particle therapy in cancer: clinical uses and future perspectives","volume":"14","author":"Durante","year":"2017","journal-title":"Nat Rev Clin Oncol"},{"key":"2026052605522649500_ref5","doi-asserted-by":"publisher","first-page":"745","DOI":"10.3109\/0284186X.2011.590148","article-title":"Status of particle therapy for lung cancer","volume":"50","author":"Liao","year":"2011","journal-title":"Acta Oncol"},{"key":"2026052605522649500_ref6","doi-asserted-by":"publisher","first-page":"e994","DOI":"10.1002\/mp.12679","article-title":"Motion management in particle therapy","volume":"45","author":"Mori","year":"2018","journal-title":"Med Phys"},{"key":"2026052605522649500_ref7","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.jvir.2008.09.026","article-title":"Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy","volume":"20","author":"Kothary","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"2026052605522649500_ref8","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1007\/s00270-009-9748-7","article-title":"CT-guided fiducial placement for cyberknife stereotactic radiosurgery: an initial experience","volume":"33","author":"Sotiropoulou","year":"2010","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2026052605522649500_ref9","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1111\/j.1754-9485.2012.02445.x","article-title":"Planting the seeds of success: CT-guided gold seed fiducial marker placement to guide robotic radiosurgery","volume":"57","author":"Patel","year":"2013","journal-title":"J Med Imaging Radiat Oncol"},{"key":"2026052605522649500_ref10","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/j.jvir.2014.01.004","article-title":"CT fluoroscopy-guided percutaneous fiducial marker placement for CyberKnife stereotactic radiosurgery: technical results and complications in 222 consecutive procedures","volume":"25","author":"Trumm","year":"2014","journal-title":"J Vasc Interv Radiol"},{"key":"2026052605522649500_ref11","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.athoracsur.2009.09.048","article-title":"Fiducial marker placement using endobronchial ultrasound and navigational bronchoscopy for stereotactic radiosurgery: an alternative strategy","volume":"89","author":"Harley","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"2026052605522649500_ref12","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1177\/000313481508100712","article-title":"Electromagnetic navigational bronchoscopy: a safe and effective method for fiducial marker placement in lung cancer patients","volume":"81","author":"Bolton","year":"2015","journal-title":"Am Surg"},{"key":"2026052605522649500_ref13","doi-asserted-by":"publisher","first-page":"1972","DOI":"10.21037\/jtd.2018.03.49","article-title":"Fiducial marker placement for stereotactic body radiation therapy via convex probe endobronchial ultrasound: a case series and review of literature","volume":"10","author":"Seides","year":"2018","journal-title":"J Thorac Dis"},{"key":"2026052605522649500_ref14","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.chest.2017.08.016","article-title":"Assessment of per-endoscopic placement of fiducial gold markers for small peripheral lung nodules &lt; 20 mm before stereotactic radiation therapy","volume":"153","author":"Lachkar","year":"2018","journal-title":"Chest."},{"key":"2026052605522649500_ref15","doi-asserted-by":"publisher","first-page":"1569","DOI":"10.1007\/s00330-008-0933-x","article-title":"Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: preliminary results","volume":"18","author":"Prevost","year":"2008","journal-title":"Eur Radiol"},{"key":"2026052605522649500_ref16","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1097\/JTO.0b013e318288ab02","article-title":"Long-term outcome of proton therapy and carbon-ion therapy for large (T2a-T2bN0M0) non-small-cell lung cancer","volume":"8","author":"Iwata","year":"2013","journal-title":"J Thorac Oncol"},{"key":"2026052605522649500_ref17","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1016\/j.jvir.2019.04.025","article-title":"Endovascular coils as lung tumor fiducial markers for real-time tumor tracking in stereotactic body radiotherapy: comparison of complication rates with transthoracic fiducial marker placement","volume":"30","author":"Baker","year":"2019","journal-title":"J Vasc Interv Radiol"},{"key":"2026052605522649500_ref18","doi-asserted-by":"publisher","first-page":"626","DOI":"10.3348\/kjr.2015.16.3.626","article-title":"Intravascular placement of metallic coils as lung tumor markers for CyberKnife stereotactic radiation therapy","volume":"16","author":"Karaman","year":"2015","journal-title":"Korean J Radiol"},{"key":"2026052605522649500_ref19","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.1016\/j.jvir.2017.05.010","article-title":"Safety and efficacy of endovascular fiducial marker insertion for CyberKnife stereotactic radiation therapy planning in early-stage lung cancer","volume":"28","author":"Mongeon","year":"2017","journal-title":"J Vasc Interv Radiol"},{"key":"2026052605522649500_ref20","doi-asserted-by":"publisher","first-page":"141","DOI":"10.2147\/LCTT.S117647","article-title":"Proton beam therapy in non-small cell lung cancer: state of the art","volume":"8","author":"Harada","year":"2017","journal-title":"Lung Cancer (Auckl)"}],"container-title":["Journal of Radiation Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jrr\/article-pdf\/67\/3\/430\/68143359\/rrag022.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jrr\/article-pdf\/67\/3\/430\/68143359\/rrag022.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T09:52:33Z","timestamp":1779789153000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jrr\/article\/67\/3\/430\/8661415"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,23]]},"references-count":20,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,4,23]]},"published-print":{"date-parts":[[2026,5,26]]}},"URL":"https:\/\/doi.org\/10.1093\/jrr\/rrag022","relation":{},"ISSN":["0449-3060","1349-9157"],"issn-type":[{"value":"0449-3060","type":"print"},{"value":"1349-9157","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,5]]},"published":{"date-parts":[[2026,4,23]]}}}