{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T12:06:47Z","timestamp":1753877207449,"version":"3.41.2"},"reference-count":6,"publisher":"Oxford University Press (OUP)","issue":"8","license":[{"start":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T00:00:00Z","timestamp":1722816000000},"content-version":"vor","delay-in-days":4,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This report details the successful endovascular repair of a ruptured thoracoabdominal aortic aneurysm in a patient with chronic type B aortic dissection. The procedure consisted of thoracic endovascular aortic repair, abdominal endovascular aortic repair, false lumen (FL) embolization with Candy-Plug, and FL stent-graft technique. The approach effectively regulated FL inflow, achieving complete FL closure. The patient was discharged without major complications including spinal cord ischemia or renal failure, and the long-term outcome is also favorable with reduction of the aneurysm size. The follow-up results have shown a reduction in the aneurysm size. This less invasive method could be an option of treatments for post-dissection thoracoabdominal aortic aneurysms, especially in ruptured cases.<\/jats:p>","DOI":"10.1093\/jscr\/rjae478","type":"journal-article","created":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T10:58:37Z","timestamp":1722855517000},"source":"Crossref","is-referenced-by-count":1,"title":["False lumen embolization and false lumen stent-graft techniques for ruptured post-dissection thoracoabdominal aneurysm"],"prefix":"10.1093","volume":"2024","author":[{"given":"Takumi","family":"Umibe","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Chiba University Hospital , 1-8-1, Inohana, Chuo-Ku, Chiba 286-0041, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hironobu","family":"Nishiori","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Chiba University Hospital , 1-8-1, Inohana, Chuo-Ku, Chiba 286-0041, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Ikeuchi","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Chiba University Hospital , 1-8-1, Inohana, Chuo-Ku, Chiba 286-0041, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shintaroh","family":"Koizumi","sequence":"additional","affiliation":[{"name":"Chiba University Hospital Department of Cardiovascular Surgery, , 1-8-1, Inohana, Chuo-Ku, Chiba 286-0041 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideki","family":"Ueda","sequence":"additional","affiliation":[{"name":"Minami-Senju Hospital , Division of Cardiology, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Goro","family":"Matsumiya","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Chiba University Hospital , 1-8-1, Inohana, Chuo-Ku, Chiba 286-0041, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,8,5]]},"reference":[{"key":"2024080510582378500_ref1","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.jtcvs.2015.12.050","article-title":"Outcomes of 3309 thoracoabdominal aortic aneurysm repairs","volume":"151","author":"Coselli","year":"2016","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2024080510582378500_ref2","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1177\/1526602816640523","article-title":"Candy-plug technique using an excluder aortic extender for distal occlusion of a large false lumen aneurysm in chronic aortic dissection","volume":"23","author":"Ogawa","year":"2016","journal-title":"J Endovasc Ther"},{"key":"2024080510582378500_ref3","doi-asserted-by":"crossref","first-page":"e004292","DOI":"10.1161\/CIRCINTERVENTIONS.116.004292","article-title":"Surgical indication for chronic aortic dissection in descending thoracic and thoracoabdominal aorta","volume":"10","author":"Oda","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"2024080510582378500_ref4","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1583\/13-4318.1","article-title":"Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique","volume":"20","author":"K\u00f6lbel","year":"2013","journal-title":"J Endovasc Ther"},{"key":"2024080510582378500_ref5","doi-asserted-by":"crossref","first-page":"101157","DOI":"10.1016\/j.jvscit.2023.101157","article-title":"Intimal tear closure by false lumen stent graft placement for postdissection thoracoabdominal aortic aneurysm","volume":"9","author":"Nishiori","year":"2023","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"2024080510582378500_ref6","doi-asserted-by":"crossref","first-page":"e009196","DOI":"10.1161\/JAHA.118.009196","article-title":"Equations for estimating the predissected diameter of the descending aorta from computed tomographic images at the onset of aortic dissection","volume":"7","author":"Yamauchi","year":"2018","journal-title":"J Am Heart Assoc"}],"container-title":["Journal of Surgical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2024\/8\/rjae478\/58735078\/rjae478.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2024\/8\/rjae478\/58735078\/rjae478.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T10:58:43Z","timestamp":1722855523000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jscr\/article\/doi\/10.1093\/jscr\/rjae478\/7726933"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,1]]},"references-count":6,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8,1]]}},"URL":"https:\/\/doi.org\/10.1093\/jscr\/rjae478","relation":{},"ISSN":["2042-8812"],"issn-type":[{"type":"electronic","value":"2042-8812"}],"subject":[],"published-other":{"date-parts":[[2024,8]]},"published":{"date-parts":[[2024,8,1]]},"article-number":"rjae478"}}