{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T12:04:56Z","timestamp":1753877096452,"version":"3.41.2"},"reference-count":9,"publisher":"Oxford University Press (OUP)","issue":"8","license":[{"start":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T00:00:00Z","timestamp":1724889600000},"content-version":"vor","delay-in-days":28,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>A 93-year-old man with a femoral fracture was admitted to the emergency department. The patient presented with severe hypoxemia and shock. Enhanced computed tomography confirmed deep venous thrombosis in the left leg and pulmonary embolism. Subsequently, an inferior vena cava filter (IVCF) was implanted. Although the IVCF was completely unsheathed for deployment, it remained fully folded and did not open; it was not deployed or retrieved. A new IVCF was successfully placed in the same position. Acute treatment for the deep venous thrombosis and further pulmonary embolism was achieved.<\/jats:p>","DOI":"10.1093\/jscr\/rjae538","type":"journal-article","created":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T04:33:02Z","timestamp":1724905982000},"source":"Crossref","is-referenced-by-count":0,"title":["Placing two inferior vena cava filters for the bail-out management of opening failure of an inferior vena cava filter"],"prefix":"10.1093","volume":"2024","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5021-8521","authenticated-orcid":false,"given":"Yohei","family":"Kawatani","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Kamagaya General Hospital , 929-6, Hatsutomi, Kamagaya-shi 273-0121, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Azusa","family":"Yoshiyama","sequence":"additional","affiliation":[{"name":"Department of Urology, Kamagaya General Hospital , 929-6, Hatsutomi, Kamagaya-shi 273-0121, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takaki","family":"Hori","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Kamagaya General Hospital , 929-6, Hatsutomi, Kamagaya-shi 273-0121, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,8,28]]},"reference":[{"key":"2024082904325353700_ref1","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1056\/NEJM199802123380701","article-title":"A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis","volume":"338","author":"Decousus","year":"1998","journal-title":"N Engl J Med"},{"key":"2024082904325353700_ref2","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.jvsv.2022.08.011","article-title":"Immediate and delayed complications of inferior vena cava filters","volume":"11","author":"Ramakrishnan","year":"2023","journal-title":"J Vasc Surg Venous Lymphat Disord"},{"key":"2024082904325353700_ref3","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1016\/j.radcr.2020.05.019","article-title":"Incomplete opening of an ALN-type inferior vena cava filter due to entanglement of the filter legs resulting in filter migration and inferior vena cava perforation","volume":"15","author":"Shimoo","year":"2020","journal-title":"Radiol Case Rep"},{"key":"2024082904325353700_ref4","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.ijscr.2015.07.016","article-title":"A rare cause of claudication treated with IVC reconstruction: a case report","volume":"14","author":"Ali","year":"2015","journal-title":"Int J Surg Case Rep"},{"key":"2024082904325353700_ref5","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S1051-0443(91)72215-X","article-title":"Incomplete opening of LGM (vena tech) filters inserted via the transjugular approach","volume":"2","author":"Reed","year":"1991","journal-title":"J Vasc Interv Radiol"},{"key":"2024082904325353700_ref6","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/S1051-0443(91)72212-4","article-title":"LGM (vena tech) vena cava filter: clinical experience in 64 patients","volume":"2","author":"Millward","year":"1991","journal-title":"J Vasc Interv Radiol"},{"key":"2024082904325353700_ref7","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1177\/1538574411400762","article-title":"Incomplete deployment of the vena tech LP filter--case series and concerns","volume":"45","author":"Contractor","year":"2011","journal-title":"Vasc Endovascular Surg"},{"key":"2024082904325353700_ref8","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.jvscit.2017.12.006","article-title":"Inferior vena cava filter misplacement in the right ovarian vein and successful removal by loop-snare technique in a patient with inferior vena cava agenesis","volume":"4","author":"Ding","year":"2018","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"2024082904325353700_ref9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1146\/annurev.med.51.1.1","article-title":"Inferior vena cava interruption: how and when?","volume":"51","author":"Girard","year":"2000","journal-title":"Annu Rev Med"}],"container-title":["Journal of Surgical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2024\/8\/rjae538\/58954281\/rjae538.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2024\/8\/rjae538\/58954281\/rjae538.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T04:33:09Z","timestamp":1724905989000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jscr\/article\/doi\/10.1093\/jscr\/rjae538\/7743338"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,1]]},"references-count":9,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8,1]]}},"URL":"https:\/\/doi.org\/10.1093\/jscr\/rjae538","relation":{},"ISSN":["2042-8812"],"issn-type":[{"type":"electronic","value":"2042-8812"}],"subject":[],"published-other":{"date-parts":[[2024,8]]},"published":{"date-parts":[[2024,8,1]]},"article-number":"rjae538"}}