{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:31:25Z","timestamp":1787668285419,"version":"build-2736575974"},"reference-count":14,"publisher":"Oxford University Press (OUP)","issue":"11","license":[{"start":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T00:00:00Z","timestamp":1732665600000},"content-version":"vor","delay-in-days":26,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>We report the laparoscopic removal of a foreign body that was embedded in the abdominal wall. To the best of our knowledge, this is the first reported case of a foreign body in the abdominal wall being laparoscopically removed. A 27-year-old man working at a forging factory presented to our hospital with abdominal pain. He reported that three hours before presentation, a metal fragment came flying from an operating power hammer and penetrated his lower right abdomen. Abdominal CT revealed a 7\u00a0mm-sized radiopaque object near the peritoneum. The foreign body was successfully removed laparoscopically with real-time fluoroscopic guidance. Percutaneous removal is usually performed when a foreign body is present in the soft tissue; however, laparoscopic removal should be considered when the foreign body is located in the abdominal wall near the peritoneum. We provide principles for the safe and minimally invasive removal of foreign bodies based on this case.<\/jats:p>","DOI":"10.1093\/jscr\/rjae669","type":"journal-article","created":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T21:37:53Z","timestamp":1732743473000},"source":"Crossref","is-referenced-by-count":1,"title":["Laparoscopic removal of a metallic foreign body embedded in the abdominal wall"],"prefix":"10.1093","volume":"2024","author":[{"given":"Mizuki","family":"Okuno","sequence":"first","affiliation":[{"name":"Department of Surgery, Asama Nanroku Komoro Medical Center , 3-3-21, Aioicho, Komoro 384-8588 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaori","family":"Takasu","sequence":"additional","affiliation":[{"name":"Department of Surgery, Asama Nanroku Komoro Medical Center , 3-3-21, Aioicho, Komoro 384-8588 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2410-0770","authenticated-orcid":false,"given":"Takamune","family":"Goto","sequence":"additional","affiliation":[{"name":"Department of Surgery, Asama Nanroku Komoro Medical Center , 3-3-21, Aioicho, Komoro 384-8588 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiyuki","family":"Yamaguchi","sequence":"additional","affiliation":[{"name":"Department of Surgery, Asama Nanroku Komoro Medical Center , 3-3-21, Aioicho, Komoro 384-8588 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Hayashi","sequence":"additional","affiliation":[{"name":"Department of Surgery, Asama Nanroku Komoro Medical Center , 3-3-21, Aioicho, Komoro 384-8588 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,11,26]]},"reference":[{"key":"2024112721373938800_ref1","doi-asserted-by":"publisher","first-page":"387","DOI":"10.3944\/AOTT.2013.2979","article-title":"Tips and tricks in the diagnostic workup and the removal of foreign bodies in extremities","volume":"47","author":"Kurtulmu\u015f","year":"2013","journal-title":"Acta Orthop Traumatol Turc"},{"key":"2024112721373938800_ref2","doi-asserted-by":"publisher","first-page":"e114","DOI":"10.1308\/rcsann.2018.0053","article-title":"Removing a metal foreign object successfully from a patient's retroperitoneal space using laparoscopy and a novel navigation system","volume":"100","author":"Wu","year":"2018","journal-title":"Ann R Coll Surg Engl"},{"key":"2024112721373938800_ref3","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.jss.2013.01.010","article-title":"The Iliad and the odyssey of metallic foreign body extraction: commentary on ``novel methods of removing metallic foreign body from human soft tissue: a report of 7390 cases''","volume":"185","author":"Iskandar","year":"2013","journal-title":"J Surg Res"},{"key":"2024112721373938800_ref4","doi-asserted-by":"publisher","first-page":"988","DOI":"10.7205\/MILMED-D-11-00450","article-title":"Sonographic localization and management of metallic fragments: a report of five cases","volume":"177","author":"Harcke","year":"2012","journal-title":"Mil Med"},{"key":"2024112721373938800_ref5","doi-asserted-by":"publisher","first-page":"424","DOI":"10.12968\/jowc.2020.29.7.424","article-title":"CT-guided mapping in the removal of an impalpable, radiopaque foreign body in subcutaneous tissue: a case report","volume":"29","author":"Omori","year":"2020","journal-title":"J Wound Care"},{"key":"2024112721373938800_ref6","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1016\/j.jvir.2010.02.010","article-title":"Percutaneous fluoroscopically guided removal of a deep retroperitoneal foreign body with a laparoscopic trocar and grasping device","volume":"21","author":"Koch","year":"2010","journal-title":"J Vasc Interv Radiol"},{"key":"2024112721373938800_ref7","doi-asserted-by":"publisher","first-page":"93","DOI":"10.4021\/jocmr2009.11.1271","article-title":"An unusual case of foreign body in the anterior abdominal wall","volume":"20","author":"Chan","year":"2010","journal-title":"J Clin Med Res"},{"key":"2024112721373938800_ref8","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1148\/rg.2020200001","article-title":"US-guided localization and removal of soft-tissue foreign bodies","volume":"40","author":"Del Cura","year":"2020","journal-title":"Radiographics"},{"key":"2024112721373938800_ref9","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.crad.2011.10.029","article-title":"Image-guided soft-tissue foreign body extraction - success and pitfalls","volume":"67","author":"Bradley","year":"2012","journal-title":"Clin Radiol"},{"key":"2024112721373938800_ref10","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1186\/s12893-019-0572-y","article-title":"Removal of a broken acupuncture needle in retroperitoneum by laparoscopy: a case report","volume":"19","author":"Liu","year":"2019","journal-title":"BMC Surg"},{"key":"2024112721373938800_ref11","doi-asserted-by":"publisher","first-page":"269","DOI":"10.3348\/kjr.2013.14.2.269","article-title":"Value of 3-dimensional CT virtual anatomy imaging in complex foreign body retrieval from soft tissues","volume":"14","author":"Yang","year":"2013","journal-title":"Korean J Radiol"},{"key":"2024112721373938800_ref12","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1111\/1556-4029.14828","article-title":"Fatal penetrating abdominal injury by a metallic projectile","volume":"67","author":"Mittal","year":"2022","journal-title":"J Forensic Sci"},{"key":"2024112721373938800_ref13","doi-asserted-by":"publisher","first-page":"e17870","DOI":"10.7759\/cureus.17870","article-title":"A potentially dangerous industrial projectile lodged in the leg of a steel factory worker","volume":"10","author":"Khurana","year":"2021","journal-title":"Cureus"},{"key":"2024112721373938800_ref14","doi-asserted-by":"publisher","first-page":"4227","DOI":"10.21037\/qims-20-1228","article-title":"Image-guided percutaneous removal of intramuscular acupuncture needles using biopsy forceps under computed tomography and fluoroscopy: a report of two cases","volume":"11","author":"Ikoma","year":"2021","journal-title":"Quant Imaging Med Surg"}],"container-title":["Journal of Surgical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2024\/11\/rjae669\/60818266\/rjae669.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2024\/11\/rjae669\/60818266\/rjae669.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T21:37:55Z","timestamp":1732743475000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jscr\/article\/doi\/10.1093\/jscr\/rjae669\/7908927"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,1]]},"references-count":14,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,11,1]]}},"URL":"https:\/\/doi.org\/10.1093\/jscr\/rjae669","relation":{},"ISSN":["2042-8812"],"issn-type":[{"value":"2042-8812","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,11]]},"published":{"date-parts":[[2024,11,1]]},"article-number":"rjae669"}}