{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:56:49Z","timestamp":1753876609396,"version":"3.41.2"},"reference-count":14,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T00:00:00Z","timestamp":1741737600000},"content-version":"vor","delay-in-days":11,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,3,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>High pressure injection injuries to upper extremities are largely rare occurrences. The direct and indirect effects of the injected substance can cause debilitating consequences for those affected and can lead to digit amputation. This case series includes three patients with high pressure injection injuries admitted to a single tertiary centre over one year. One patient was discharged from both plastic surgery and hand therapy 6\u00a0months post injury. He reports good function but has residual numbness and cold intolerance. The second individual is still linked to surgical outpatients and has ongoing hand therapy requirements, stiffness, and numbness 12\u00a0months post injury. The final patient represented three months post initial debridement with an infected finger that required amputation. Based on these findings, it is imperative that prompt surgical debridement occurs in conjunction with early hand therapy intervention to achieve optimal outcomes for patients.<\/jats:p>","DOI":"10.1093\/jscr\/rjaf127","type":"journal-article","created":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T03:41:03Z","timestamp":1741750863000},"source":"Crossref","is-referenced-by-count":0,"title":["Case series of high pressure paint injection injuries in single digits in a tertiary referral centre over a one year period"],"prefix":"10.1093","volume":"2025","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0391-7837","authenticated-orcid":false,"given":"Aine","family":"Cotter","sequence":"first","affiliation":[{"name":"Plastic Surgery Department, St James\u2019s Hospital , Dublin, D08 NHY1 ,","place":["Ireland"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marlese","family":"Dempsey","sequence":"additional","affiliation":[{"name":"Plastic Surgery Department, St James\u2019s Hospital , Dublin, D08 NHY1 ,","place":["Ireland"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Buckley","sequence":"additional","affiliation":[{"name":"Plastic Surgery Department, St James\u2019s Hospital , Dublin, D08 NHY1 ,","place":["Ireland"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Odhran","family":"Shelley","sequence":"additional","affiliation":[{"name":"Plastic Surgery Department, St James\u2019s Hospital , Dublin, D08 NHY1 ,","place":["Ireland"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2025,3,12]]},"reference":[{"key":"2025031203405184900_ref1","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1016\/0266-7681(93)90024-A","article-title":"Injuries to the hand and wrist. A study of 50,272 injuries","volume":"18","author":"Angermann","year":"1993","journal-title":"J Hand Surg"},{"key":"2025031203405184900_ref2","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1053\/ajem.2000.18051","article-title":"High-pressure injection injuries to the hand","volume":"18","author":"Vasilevski","year":"2000","journal-title":"Am J of Emerg Med"},{"key":"2025031203405184900_ref3","doi-asserted-by":"publisher","first-page":"2000","DOI":"10.3390\/jcm8112000","article-title":"Management of high-pressure injection hand injuries: a multicentric, retrospective, observational study","volume":"16","author":"Vitale","year":"2019","journal-title":"J Clin Med"},{"key":"2025031203405184900_ref4","first-page":"277","article-title":"Die chirurgische und gerichtichmedizinische bedeutung der kunstlich hervogerufenen erkrankungen","volume":"136","author":"Hesse","year":"1925","journal-title":"Arch Klin Chir"},{"key":"2025031203405184900_ref5","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1001\/jama.1937.92780370004012c","article-title":"Penetration of tissue by fuel oil under high pressure from a diesel engine","volume":"109","author":"Rees","year":"1937","journal-title":"JAMA"},{"key":"2025031203405184900_ref6","doi-asserted-by":"publisher","first-page":"586e","DOI":"10.1097\/PRS.0b013e31829f4bb4","article-title":"High-pressure injection injuries in the hand: current treatment concepts","volume":"132","author":"Amsdell","year":"2013","journal-title":"Plast Reconstr Surg"},{"key":"2025031203405184900_ref7","doi-asserted-by":"publisher","first-page":"64","DOI":"10.4103\/IJCIIS.IJCIIS_77_18","article-title":"High-pressure injection injuries to the hand: a 14-year descriptive study","volume":"9","author":"Muneer","year":"2019","journal-title":"Int J Crit Illn Inj Sci"},{"key":"2025031203405184900_ref8","doi-asserted-by":"publisher","first-page":"38","DOI":"10.5435\/JAAOS-22-01-38","article-title":"High-pressure injection injuries to the hand","volume":"22","author":"Rosenwasser","year":"2014","journal-title":"J Am Acad Orthop Surg"},{"volume-title":"StatPearls [Internet]","year":"2024","author":"Hadeed","key":"2025031203405184900_ref9"},{"key":"2025031203405184900_ref10","first-page":"48","article-title":"Management of high pressure injuries","volume":"10","author":"Yim","year":"2022","journal-title":"JTO"},{"key":"2025031203405184900_ref11","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1055\/s-2001-17765","article-title":"Hochdruck-Einspritzverletzungen der hand - Pathogenese, Probleme und Therapie [High-pressure injection injuries of the hand. Pathogenesis, problems and therapy]","volume":"33","author":"Rappold","year":"2001","journal-title":"Handchir Mikrochir Plast Chir"},{"key":"2025031203405184900_ref12","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1016\/j.hansur.2019.07.010","article-title":"High-pressure injection injuries of the fingers: long-term follow-up in patients after extensive debridement","volume":"38","author":"Feldman","year":"2019","journal-title":"Hand Surg Rehabil"},{"key":"2025031203405184900_ref13","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/0020-1383(91)90131-W","article-title":"High-pressure injection injuries","volume":"22","author":"Neal","year":"1991","journal-title":"Injury"},{"key":"2025031203405184900_ref14","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/S0266-7681(98)80126-5","article-title":"A 10-year review of high-pressure injection injuries to the hand","volume":"23","author":"Lewis","year":"1998","journal-title":"J Hand Surg"}],"container-title":["Journal of Surgical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2025\/3\/rjaf127\/62382175\/rjaf127.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2025\/3\/rjaf127\/62382175\/rjaf127.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T03:41:06Z","timestamp":1741750866000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jscr\/article\/doi\/10.1093\/jscr\/rjaf127\/8071257"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,3,3]]}},"URL":"https:\/\/doi.org\/10.1093\/jscr\/rjaf127","relation":{},"ISSN":["2042-8812"],"issn-type":[{"type":"electronic","value":"2042-8812"}],"subject":[],"published-other":{"date-parts":[[2025,3]]},"published":{"date-parts":[[2025,3]]},"article-number":"rjaf127"}}