{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T17:28:16Z","timestamp":1772213296299,"version":"3.50.1"},"reference-count":15,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"vor","delay-in-days":27,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Entero-atmospheric fistula (EAF) is a serious complication of open abdomen (OA) treatment, especially when high output effluent leads to sepsis, electrolyte imbalance, and wound deterioration. Traditional diversion methods often cannot effectively control production. This report describes a 76-year-old man who developed a high output EAF (about 800\u00a0mL\/d) after OA due to colonic necrosis and intra-abdominal sepsis. A variety of interventions (including negative pressure wound treatment adjustment, catheter bypass, and attempts to directly repair) were unsuccessful, and the fistula gradually expanded. According to the patient\u2019s wound anatomy, a custom-made floating stoma was created using food-grade silicone, which successfully raised the fistula, shunted the effluent, and reduced chemical damage. This case shows that the low-cost and personalized silicone floating stoma can effectively control the high output EAF and protect the wound environment, which is a practical choice in the case of limited resources. Compared with many commercial isolation devices that may cost several hundred US dollars per unit, this customized silicone floating stoma can be manufactured for &amp;lt; $50 per patient.<\/jats:p>","DOI":"10.1093\/jscr\/rjag105","type":"journal-article","created":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T12:47:48Z","timestamp":1770209268000},"source":"Crossref","is-referenced-by-count":0,"title":["A low-cost customized silicone floating stoma for the management of high-output entero-atmospheric fistula: a case report"],"prefix":"10.1093","volume":"2026","author":[{"given":"Gang","family":"Cao","sequence":"first","affiliation":[{"name":"Department of Surgery, Second People\u2019s Hospital of Guizhou Province , No. 206, South Section of Xintian Avenue, Yunyan District, Guiyang, Guizhou Province 550000 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miaoju","family":"Nie","sequence":"additional","affiliation":[{"name":"Department of Surgery, Second People\u2019s Hospital of Guizhou Province , No. 206, South Section of Xintian Avenue, Yunyan District, Guiyang, Guizhou Province 550000 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuxiang","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Surgery, Second People\u2019s Hospital of Guizhou Province , No. 206, South Section of Xintian Avenue, Yunyan District, Guiyang, Guizhou Province 550000 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong","family":"Wen","sequence":"additional","affiliation":[{"name":"Department of Surgery, Second People\u2019s Hospital of Guizhou Province , No. 206, South Section of Xintian Avenue, Yunyan District, Guiyang, Guizhou Province 550000 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4483-6067","authenticated-orcid":false,"given":"Changxiao","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Surgery, Second People\u2019s Hospital of Guizhou Province , No. 206, South Section of Xintian Avenue, Yunyan District, Guiyang, Guizhou Province 550000 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,2,27]]},"reference":[{"key":"2026022711503851600_ref1","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3390\/jcm13051279","article-title":"Entero-cutaneous and Entero-atmospheric fistulas: insights into management using negative pressure wound therapy","volume":"13","author":"Pepe","year":"2024","journal-title":"J Clin Med"},{"key":"2026022711503851600_ref2","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1097\/TA.0000000000004608","article-title":"Management of Enteroatmospheric Fistulas: what you need to know","volume":"99","author":"Rezende-Neto","year":"2025","journal-title":"J Trauma Acute Care Surg"},{"key":"2026022711503851600_ref3","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1016\/j.surg.2022.12.001","article-title":"Management of enteroatmospheric fistula: a ten-year experience following fifteen years of learning","volume":"173","author":"Wainstein","year":"2023","journal-title":"Surgery"},{"key":"2026022711503851600_ref4","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1111\/iwj.12597","article-title":"Management of enteroatmospheric fistula with negative pressure wound therapy in open abdomen treatment: a multicentre observational study","volume":"14","author":"Bobkiewicz","year":"2016","journal-title":"Int Wound J"},{"key":"2026022711503851600_ref5","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1007\/s00268-022-06733-4","article-title":"Patients with an open abdomen in Asian, American and European continents: a comparative analysis from the international register of open abdomen (IROA)","volume":"47","author":"Sibilla","year":"2022","journal-title":"World J Surg"},{"key":"2026022711503851600_ref6","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.amsu.2021.102413","article-title":"Postoperative enterocutaneous fistulas: management outcomes in 23 consecutive patients","volume":"66","author":"Noori","year":"2021","journal-title":"Ann Med Surg"},{"key":"2026022711503851600_ref7","doi-asserted-by":"publisher","first-page":"12","DOI":"10.33448\/rsd-v12i2.40057","article-title":"F\u00edstulas enterocut\u00e2neas e enteroatmosf\u00e9ricas \u2013 terap\u00eauticas e a enfermagem: revis\u00e3o de literatura","volume":"12","author":"Costa","year":"2023","journal-title":"Res Soc Dev"},{"key":"2026022711503851600_ref8","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1002\/btm2.10583","article-title":"Personalized additive manufacturing of devices for the management of enteroatmospheric fistulas","volume":"8","author":"Calero Castro","year":"2023","journal-title":"Bioeng Transl Med"},{"key":"2026022711503851600_ref9","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1136\/tsaco-2019-000381","article-title":"Challenge of uncontrolled enteroatmospheric fistulas","volume":"4","author":"Gross","year":"2019","journal-title":"Trauma Surg Acute Care Open"},{"key":"2026022711503851600_ref10","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.ijscr.2020.09.024","article-title":"Unusual techniques in the management of enteroatmospheric fistula. Report of a case","volume":"75","author":"Saleem","year":"2020","journal-title":"Int J Surg Case Rep"},{"key":"2026022711503851600_ref11","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3390\/jpm12020292","article-title":"Failure to rescue (FTR) and pitfalls in the management of complex enteric fistulas (CEF): from rescue surgery to rescue strategy","volume":"12","author":"Cioffi","year":"2022","journal-title":"J Pers Med"},{"key":"2026022711503851600_ref12","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.37668","article-title":"Management of enteroatmospheric fistula (EAF) using a fistula-vacuum assisted closure (VAC) in a complicated abdominal trauma case","volume":"15","author":"English","year":"2023","journal-title":"Cureus"},{"key":"2026022711503851600_ref13","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1038\/s41598-020-74213-7","article-title":"Using a bio-scanner and 3D printing to create an innovative custom made approach for the management of complex entero-atmospheric fistulas","volume":"10","author":"Dur\u00e1n Mu\u00f1oz-Cruzado","year":"2020","journal-title":"Sci Rep"},{"key":"2026022711503851600_ref14","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3389\/fsurg.2020.559443","article-title":"Technique advances in Enteroatmospheric fistula isolation after open abdomen:a review and outlook","volume":"7","author":"Huang","year":"2021","journal-title":"Front Surgery"},{"key":"2026022711503851600_ref15","author":"Wright","year":"2020"}],"container-title":["Journal of Surgical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2026\/2\/rjag105\/67156890\/rjag105.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2026\/2\/rjag105\/67156890\/rjag105.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T16:50:42Z","timestamp":1772211042000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jscr\/article\/doi\/10.1093\/jscr\/rjag105\/8501303"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,31]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,1,31]]}},"URL":"https:\/\/doi.org\/10.1093\/jscr\/rjag105","relation":{},"ISSN":["2042-8812"],"issn-type":[{"value":"2042-8812","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,2]]},"published":{"date-parts":[[2026,1,31]]},"article-number":"rjag105"}}