{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T07:28:35Z","timestamp":1793777315353,"version":"4.6.1"},"reference-count":13,"publisher":"Oxford University Press (OUP)","issue":"10","license":[{"start":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T00:00:00Z","timestamp":1791072000000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,10,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Type III endoleaks, from disconnection between modular stent-graft components (type IIIa) or fabric defects within a limb (type IIIb), are uncommon but potentially life-threatening, transmitting systemic pressure into the aneurysm sac and carrying a high rupture risk. We describe three men with late type III endoleak failure after complex thoracic aortic repair. One presented with rupture at a mid-thoracic modular overlap, salvaged by emergency relining via a hostile femoral cut-down. A second, under surveillance for an asymptomatic endoleak managed conservatively given a static sac, later ruptured at a separate site and died despite emergency relining. A third developed a type IIIb fabric failure in a highly angulated aortic arch, salvaged using a conformable stent-graft and left-ventricular through-and-through wire support. These cases show type III endoleaks may be radiologically subtle yet rapidly fatal, sac stability alone should not determine management, and complex arch morphology demands tailored device selection and access planning.<\/jats:p>","DOI":"10.1093\/jscr\/rjag887","type":"journal-article","created":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T19:34:23Z","timestamp":1789673663000},"source":"Crossref","is-referenced-by-count":0,"title":["Type III endoleaks following endovascular aortic repair: a case series"],"prefix":"10.1093","volume":"2026","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-4351-9510","authenticated-orcid":false,"given":"Buraq","family":"Ahmed","sequence":"first","affiliation":[{"name":"School of Clinical Medicine, University of Cambridge, Addenbrooke's Hospital , Hills Rd, Cambridge CB2 0SP ,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Chan","sequence":"additional","affiliation":[{"name":"School of Clinical Medicine, University of Cambridge, Addenbrooke's Hospital , Hills Rd, Cambridge CB2 0SP ,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maite Del Campo","family":"Martinez","sequence":"additional","affiliation":[{"name":"School of the Biological Sciences, University of Cambridge , 17 Mill Lane Cambridge CB2 1RX ,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hariesha","family":"Pathmaraj","sequence":"additional","affiliation":[{"name":"School of Clinical Medicine, University of Cambridge, Addenbrooke's Hospital , Hills Rd, Cambridge CB2 0SP ,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"Grieco","sequence":"additional","affiliation":[{"name":"Radiology Department, Cambridge University Hospitals NHS Foundation Trust , Addenbrooke's Hospital, Hills Rd, Cambridge CB2 0SP ,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,10,4]]},"reference":[{"key":"2026110401425570900_ref1","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1055\/s-0043-1771343","article-title":"Endovascular repair of thoracoabdominal aortic aneurysm: a brief review","volume":"33","author":"Tohme","year":"2023","journal-title":"Int J Angiol"},{"key":"2026110401425570900_ref2","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1055\/s-0040-1715874","article-title":"Review of type III endoleaks","volume":"37","author":"Stoecker","year":"2020","journal-title":"Semin Interv Radiol"},{"key":"2026110401425570900_ref3","doi-asserted-by":"publisher","first-page":"1172","DOI":"10.1016\/j.jvs.2021.10.038","article-title":"Type 3 endoleaks in complex endovascular abdominal aortic aneurysm repair within the vascular quality initiative","volume":"75","author":"Blakeslee-Carter","year":"2022","journal-title":"J Vasc Surg"},{"key":"2026110401425570900_ref4","doi-asserted-by":"publisher","first-page":"1056","DOI":"10.1016\/j.jvs.2017.01.056","article-title":"Incidence, etiology, and management of type III endoleak after endovascular aortic repair","volume":"66","author":"Maleux","year":"2017","journal-title":"J Vasc Surg"},{"key":"2026110401425570900_ref5","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jvs.2017.10.044","article-title":"The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm","volume":"67","author":"Chaikof","year":"2018","journal-title":"J Vasc Surg"},{"key":"2026110401425570900_ref6","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.ejvs.2018.09.020","article-title":"European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms","volume":"57","author":"Wanhainen","year":"2019","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2026110401425570900_ref7","doi-asserted-by":"publisher","first-page":"55S","DOI":"10.1016\/j.jvs.2020.05.076","article-title":"Society for Vascular Surgery clinical practice guidelines of thoracic endovascular aortic repair for descending thoracic aortic aneurysms","volume":"73","author":"Upchurch","year":"2021","journal-title":"J Vasc Surg"},{"key":"2026110401425570900_ref8","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.ejvs.2025.12.050","article-title":"European Society for Vascular Surgery (ESVS) 2026 clinical practice guidelines on the management of descending thoracic and thoraco-abdominal aortic diseases","volume":"71","author":"Wanhainen","year":"2026","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2026110401425570900_ref9","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/j.jvs.2021.04.018","article-title":"A preliminary analysis of late structural failures of the Navion stent graft in the treatment of descending thoracic aortic aneurysms","volume":"74","author":"Verzini","year":"2021","journal-title":"J Vasc Surg"},{"key":"2026110401425570900_ref10","doi-asserted-by":"publisher","first-page":"328.e1","DOI":"10.1016\/j.avsg.2018.03.026","article-title":"Thoracic stent grafting through transapical approach for type III Endoleak due to prosthetic disconnection","volume":"51","author":"Mart\u00ednez L\u00f3pez","year":"2018","journal-title":"Ann Vasc Surg"},{"key":"2026110401425570900_ref11","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1016\/j.jvs.2025.02.048","article-title":"Rupture after previous endovascular abdominal aortic aneurysm repair: a meta-analysis and meta-regression analysis of factors influencing perioperative mortality","volume":"82","author":"Koudounas","year":"2025","journal-title":"J Vasc Surg"},{"key":"2026110401425570900_ref12","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1177\/1526602815601405","article-title":"Late rupture of abdominal aortic aneurysm after previous endovascular repair: a systematic review and meta-analysis","volume":"22","author":"Antoniou","year":"2015","journal-title":"J Endovasc Ther"},{"key":"2026110401425570900_ref13","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1002\/bjs.9181","article-title":"Type II endoleak after endovascular aneurysm repair","volume":"100","author":"Sidloff","year":"2013","journal-title":"Br J Surg"}],"container-title":["Journal of Surgical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2026\/10\/rjag887\/71577880\/rjag887.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jscr\/article-pdf\/2026\/10\/rjag887\/71577880\/rjag887.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T06:43:02Z","timestamp":1793774582000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jscr\/article\/doi\/10.1093\/jscr\/rjag887\/8860367"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":13,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10,3]]}},"URL":"https:\/\/doi.org\/10.1093\/jscr\/rjag887","relation":{},"ISSN":["2042-8812"],"issn-type":[{"value":"2042-8812","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,10]]},"published":{"date-parts":[[2026,10]]},"article-number":"rjag887"}}