{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T23:16:32Z","timestamp":1769037392684,"version":"3.49.0"},"reference-count":33,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T00:00:00Z","timestamp":1768953600000},"content-version":"vor","delay-in-days":20,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The FreeStyle Libre 3 (FSL3) continuous glucose monitoring system (CGMS) is accurate in diabetic people, and its smaller size could be advantageous in veterinary patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Hypothesis\/Objectives<\/jats:title>\n                    <jats:p>Assess the clinical and analytical accuracy, sensor lifespan, and frequency of complications of the FSL3 in diabetic cats.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Animals<\/jats:title>\n                    <jats:p>Twenty client-owned diabetic cats.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Interstitial glucose concentrations (IG) measured using the FSL3 were compared to blood glucose concentrations (BG) measured using the AlphaTRAK2. Skin reactions at the application site and sensor lifespan were recorded. Spearman\u2019s correlation coefficient, Bland\u2013Altman test, and Parkes error grid analysis (EGA) were used to evaluate correlation, bias, and clinical accuracy, respectively. Analytical accuracy was assessed using the mean absolute relative difference (MARD).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Median sensor lifespan was 11\u00a0days (range, 4-14). After sensor removal, 4 cats had a mild erythema at the application site. A total of 288 paired IG-BG measurements were recorded, the majority of which (279\/288, 97%) were in the euglycemic (70-180\u00a0mg\/dL) and hyperglycemic (&amp;gt;180\u00a0mg\/dL) ranges. A strong positive correlation was observed between IG and BG readings (rs\u00a0=\u00a00.95; &amp;lt;\u20090.0001). Comparison of IG and BG measurements resulted in a MARD of 13.6% and an overall negative bias of \u221219.4\u00a0\u00b1\u00a046.0\u00a0mg\/dL. Clinical accuracy was demonstrated, with 99.7% (287\/288) of the results in zones A\u00a0+\u00a0B of the Parkes EGA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and clinical importance<\/jats:title>\n                    <jats:p>FreeStyle Libre 3 provides clinically accurate measurements in the euglycemic and hyperglycemic ranges in diabetic cats. The smaller size of the FSL3 may improve adherence and long-term use of CGMS in diabetic cats.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/jvimsj\/aalaf049","type":"journal-article","created":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T09:02:36Z","timestamp":1768986156000},"source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of the FreeStyle Libre 3 in client-owned diabetic cats"],"prefix":"10.1093","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-3636-0415","authenticated-orcid":false,"given":"Antonio M","family":"Tardo","sequence":"first","affiliation":[{"name":"Department of Veterinary Medical Sciences, University of Bologna , Ozzano dell\u2019Emilia ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5577-0657","authenticated-orcid":false,"given":"Francesca","family":"Del Baldo","sequence":"additional","affiliation":[{"name":"Department of Veterinary Medical Sciences, University of Bologna , Ozzano dell\u2019Emilia ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Bonzagni","sequence":"additional","affiliation":[{"name":"Department of Veterinary Medical Sciences, University of Bologna , Ozzano dell\u2019Emilia ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valeria","family":"Pergolese","sequence":"additional","affiliation":[{"name":"Department of Veterinary Medical Sciences, University of Bologna , Ozzano dell\u2019Emilia ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1673-8715","authenticated-orcid":false,"given":"Andrea","family":"Corsini","sequence":"additional","affiliation":[{"name":"Department of Veterinary Sciences, University of Parma , Parma ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3444-2910","authenticated-orcid":false,"given":"Francesca","family":"Fidanzio","sequence":"additional","affiliation":[{"name":"Department of Veterinary Sciences, University of Parma , Parma ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0393-4135","authenticated-orcid":false,"given":"Chen","family":"Gilor","sequence":"additional","affiliation":[{"name":"Department of Small Animal Clinical Sciences, University of Florida, College of Veterinary Medicine , Gainesville, FL ,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3121-2199","authenticated-orcid":false,"given":"Federico","family":"Fracassi","sequence":"additional","affiliation":[{"name":"Department of Veterinary Medical Sciences, University of Bologna , Ozzano dell\u2019Emilia ,","place":["Italy"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,1,21]]},"reference":[{"key":"2026012104022385100_ref1","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/B978-1-4557-4456-5.00007-9","volume-title":"Canine and Feline Endocrinology","author":"Reusch","year":"2015","edition":"4th"},{"key":"2026012104022385100_ref2","first-page":"468","volume-title":"Feline Endocrinology","author":"Fracassi","year":"2019","edition":"1st"},{"key":"2026012104022385100_ref3","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1016\/j.jfms.2009.04.010","article-title":"Intensive blood glucose control is safe and effective in diabetic cats using home monitoring and treatment with glargine","volume":"11","author":"Roomp","year":"2009","journal-title":"J Feline Med Surg"},{"key":"2026012104022385100_ref4","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1177\/1098612X17727692","article-title":"Acceptance of home blood glucose monitoring by owners of recently diagnosed diabetic cats and impact on quality of life changes in cat and owner","volume":"20","author":"Hazuchova","year":"2018","journal-title":"J Feline Med Surg"},{"key":"2026012104022385100_ref5","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1080\/01652176.2014.924057","article-title":"In cats with newly diagnosed diabetes mellitus, use of a near-euglycemic management paradigm improves remission rate over a traditional paradigm","volume":"34","author":"Nack","year":"2014","journal-title":"Vet Q"},{"key":"2026012104022385100_ref6","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/j.cvsm.2023.01.008","article-title":"Continuous glucose monitoring in dogs and cats: application of new technology to an old problem","volume":"53","author":"Del Baldo","year":"2023","journal-title":"Vet Clin North Am Small Anim Pract"},{"key":"2026012104022385100_ref7","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"key":"2026012104022385100_ref8","doi-asserted-by":"publisher","first-page":"2296","DOI":"10.1111\/jvim.15930","article-title":"Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus","volume":"34","author":"Del Baldo","year":"2020","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref9","doi-asserted-by":"publisher","first-page":"1703","DOI":"10.1111\/jvim.16216","article-title":"Validation of a flash glucose monitoring system in outpatient diabetic cats","volume":"35","author":"Shea","year":"2021","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref10","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.rvsc.2020.09.015","article-title":"Use of the \u201cFreeStyle Libre\u201d glucose monitoring system in diabetic cats","volume":"135","author":"Deiting","year":"2021","journal-title":"Res Vet Sci"},{"key":"2026012104022385100_ref11","doi-asserted-by":"publisher","first-page":"1279","DOI":"10.1111\/jvim.16122","article-title":"Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations","volume":"35","author":"Del Baldo","year":"2021","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref12","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1177\/1098612X221104051","article-title":"Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus","volume":"24","author":"Knies","year":"2022","journal-title":"J Feline Med Surg"},{"key":"2026012104022385100_ref13","doi-asserted-by":"publisher","first-page":"1703","DOI":"10.1111\/jvim.16820","article-title":"Assessment of the FreeStyle Libre 2 interstitial glucose monitor in hypo- and euglycemic cats","volume":"37","author":"Berg","year":"2023","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref14","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1177\/1098612X20965012","article-title":"Complications associated with a flash glucose monitoring system in diabetic cats","volume":"23","author":"Shoelson","year":"2021","journal-title":"J Feline Med Surg"},{"key":"2026012104022385100_ref15","doi-asserted-by":"publisher","first-page":"203","DOI":"10.3390\/vetsci10030203","article-title":"Monitoring of diabetes mellitus using the flash glucose monitoring system: the owners\u2019 point of view","volume":"10","author":"Re","year":"2023","journal-title":"Vet Sci"},{"key":"2026012104022385100_ref16","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1007\/s13300-023-01385-6","article-title":"Accuracy of the third generation of a 14-day continuous glucose monitoring system","volume":"14","author":"Alva","year":"2023","journal-title":"Diabetes Ther"},{"key":"2026012104022385100_ref17","doi-asserted-by":"publisher","first-page":"e70048","DOI":"10.1111\/jvim.70048","article-title":"Accuracy of the Freestyle Libre 3 continuous glucose monitoring system in hypo- and euglycemic cats","volume":"39","author":"Tardo","year":"2025","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref18","volume-title":"Project ALIVE, Term Definition \u201cALIVE criteria for diagnosing DM in cats\u201d","author":"European Society of Veterinary Endocrinology","year":"2020"},{"key":"2026012104022385100_ref19","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1024\/0036-7281.151.9.448","article-title":"Evaluation of new portable blood glucose meter designed for the use in cats","volume":"151","author":"Zini","year":"2009","journal-title":"Schweizer Arch Tierh"},{"key":"2026012104022385100_ref20","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1177\/193229681300700517","article-title":"Technical aspects of the Parkes error grid","volume":"7","author":"Pf\u00fctzner","year":"2013","journal-title":"J Diabetes Sci Technol"},{"key":"2026012104022385100_ref21","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1177\/1932296815586013","article-title":"Performance comparison of CGM systems: MARD values are not always a reliable indicator of CGM system accuracy","volume":"9","author":"Kirchsteiger","year":"2015","journal-title":"J Diabetes Sci Technol"},{"key":"2026012104022385100_ref22","doi-asserted-by":"publisher","first-page":"2120","DOI":"10.1111\/jvim.17106","article-title":"A dose titration protocol for once-daily insulin glargine 300\u2009U\/mL for the treatment of diabetes mellitus in dogs","volume":"38","author":"Tardo","year":"2024","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref23","year":"2022"},{"key":"2026012104022385100_ref24","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1111\/j.1939-1676.2009.0425.x","article-title":"Evaluation of a novel real-time continuous glucose-monitoring system for use in cats","volume":"24","author":"Moretti","year":"2010","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref25","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.applanim.2014.10.005","article-title":"Comparison of stress exhibited by cats examined in a clinic versus a home setting","volume":"173","author":"Nibblett","year":"2015","journal-title":"Appl Anim Behav Sci"},{"key":"2026012104022385100_ref26","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1111\/j.1939-1676.2002.tb02343.x","article-title":"Acute stress hyperglycemia in cats is associated with struggling and increased concentrations of lactate and norepinephrine","volume":"16","author":"Rand","year":"2002","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref27","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1177\/1932296818812062","article-title":"Measures of accuracy for continuous glucose monitoring and blood glucose monitoring devices","volume":"13","author":"Freckmann","year":"2019","journal-title":"J Diabetes Sci Technol"},{"key":"2026012104022385100_ref28","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.2337\/dc17-1600","article-title":"International consensus on use of continuous glucose monitoring","volume":"40","author":"Danne","year":"2017","journal-title":"Diabetes Care"},{"key":"2026012104022385100_ref29","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1177\/1479164118756240","article-title":"Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: implications for clinical practice","volume":"15","author":"Ajjan","year":"2018","journal-title":"Diab Vasc Dis Res"},{"key":"2026012104022385100_ref30","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1111\/jvim.15657","article-title":"Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis","volume":"34","author":"Malerba","year":"2020","journal-title":"J Vet Intern Med"},{"key":"2026012104022385100_ref31","doi-asserted-by":"crossref","first-page":"860","DOI":"10.3390\/ani12070860","article-title":"Clinical use of a 180-day implantable glucose monitoring system in dogs with diabetes mellitus: a case series","volume":"12","author":"Tardo","year":"2022","journal-title":"Animals (Basel)"},{"key":"2026012104022385100_ref32","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.2460\/javma.23.02.0103","article-title":"Interstitial glucose monitoring has acceptable clinical accuracy in juvenile dogs","volume":"261","author":"Vigh","year":"2023","journal-title":"J Am Vet Med Assoc"},{"key":"2026012104022385100_ref33","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1177\/1932296819855670","article-title":"Benefits and limitations of MARD as a performance parameter for continuous glucose monitoring in the interstitial space","volume":"14","author":"Heinemann","year":"2020","journal-title":"J Diabetes Sci Technol"}],"container-title":["Journal of Veterinary Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jvim\/article-pdf\/40\/1\/aalaf049\/66458572\/aalaf049.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jvim\/article-pdf\/40\/1\/aalaf049\/66458572\/aalaf049.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T09:02:38Z","timestamp":1768986158000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jvim\/article\/doi\/10.1093\/jvimsj\/aalaf049\/8429720"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1,21]]}},"URL":"https:\/\/doi.org\/10.1093\/jvimsj\/aalaf049","relation":{},"ISSN":["1939-1676"],"issn-type":[{"value":"1939-1676","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,1]]},"published":{"date-parts":[[2026,1]]},"article-number":"aalaf049"}}