{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T17:27:02Z","timestamp":1768411622872,"version":"3.49.0"},"reference-count":32,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2023,3,15]],"date-time":"2023-03-15T00:00:00Z","timestamp":1678838400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003382","name":"JST CREST","doi-asserted-by":"publisher","award":["JPMJCR19H2"],"award-info":[{"award-number":["JPMJCR19H2"]}],"id":[{"id":"10.13039\/501100003382","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"JSPS KAKENHI","doi-asserted-by":"publisher","award":["19H03230"],"award-info":[{"award-number":["19H03230"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,6,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Electron microscopes can observe samples with a spatial resolution of 10 nm or higher; however, they cannot observe samples in solutions due to the vacuum conditions inside the sample chamber. Recently, we developed a scanning electron-assisted dielectric microscope (SE-ADM), based on scanning electron microscope, which enables the observation of various specimens in solution. Until now, the SE-ADM system used a custom-made SE-ADM stage with a built-in amplifier and could not be linked to the scanning electron microscopy (SEM) operation system. Therefore, it was necessary to manually acquire images from the SE-ADM system after setting the EB focus, astigmatism, and observation field-of-view from the SEM operating console. In this study, we developed a general-purpose dielectric constant imaging unit attached to commercially available SEMs. The new SE-ADM unit can be directly attached to the standard stage of an SEM, and the dielectric signal detected from this unit can be input to the external input terminal of the SEM, enabling simultaneous observation yielding SEM and SE-ADM images. Furthermore, 4.5 nm spatial resolution was achieved using a 10 nm thick silicon nitride film in the sample holder in the observation of aggregated PM2.5. We carried out the observation of cultured cells, PM2.5, and clay samples in solution.<\/jats:p>","DOI":"10.1093\/micmic\/ozad030","type":"journal-article","created":{"date-parts":[[2023,3,15]],"date-time":"2023-03-15T13:05:51Z","timestamp":1678885551000},"page":"1037-1046","source":"Crossref","is-referenced-by-count":5,"title":["Development of General-purpose Dielectric Constant Imaging Unit for SEM and Direct Observation of Samples in Aqueous Solution"],"prefix":"10.1093","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8953-6562","authenticated-orcid":false,"given":"Toshihiko","family":"Ogura","sequence":"first","affiliation":[{"name":"Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST) , Central 6, Higashi 1-1-1, Tsukuba, Ibaraki 305-8566 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoko","family":"Okada","sequence":"additional","affiliation":[{"name":"Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST) , Central 6, Higashi 1-1-1, Tsukuba, Ibaraki 305-8566 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michio","family":"Hatano","sequence":"additional","affiliation":[{"name":"Hitachi High-Tech Corporation , Ichige 882, Hitachinaka, Ibaraki 312-8504 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuhiro","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Hitachi High-Tech Corporation , Ichige 882, Hitachinaka, Ibaraki 312-8504 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshihide","family":"Agemura","sequence":"additional","affiliation":[{"name":"Hitachi High-Tech Corporation , Ichige 882, Hitachinaka, Ibaraki 312-8504 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2023,3,15]]},"reference":[{"key":"2023060912180744400_ozad030-B1","doi-asserted-by":"crossref","first-page":"8004","DOI":"10.1002\/anie.201303740","article-title":"Electron-beam-induced deposition of bimetallic nanostructures from bulk liquids","volume":"52","author":"Bresin","year":"2013","journal-title":"Angew Chem Int Ed"},{"key":"2023060912180744400_ozad030-B2","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1002\/mas.20115","article-title":"Chemical and microphysical characterization of ambient aerosols with the aerodyne aerosol mass spectrometer","volume":"26","author":"Canagaratna","year":"2007","journal-title":"Mass Spectrom Rev"},{"key":"2023060912180744400_ozad030-B3","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.micron.2004.02.003","article-title":"Radiation damage in the TEM and SEM","volume":"35","author":"Egerton","year":"2004","journal-title":"Micron"},{"key":"2023060912180744400_ozad030-B4","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1063\/1.555977","article-title":"A database for the static dielectric constant of water and steam","volume":"24","author":"Fernandez","year":"1995","journal-title":"J Phys Chem Ref Data"},{"key":"2023060912180744400_ozad030-B5","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.sbi.2006.03.013","article-title":"Structure of the rhodopsin dimer: A working model for G-protein-coupled receptors","volume":"16","author":"Fotiadis","year":"2006","journal-title":"Curr Opin Struct Biol"},{"key":"2023060912180744400_ozad030-B6","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/sca.1998.4950200105","article-title":"Mean atomic number and backscattered electron coefficient calculations for some materials with low mean atomic number","volume":"20","author":"Howell","year":"1998","journal-title":"Scanning"},{"key":"2023060912180744400_ozad030-B7","doi-asserted-by":"crossref","first-page":"6435","DOI":"10.1021\/acs.langmuir.1c00404","article-title":"Direct observation of the relationship between thixotropic behavior and shear-induced orientation of clay particles in synesthetic hectorite suspensions","volume":"37","author":"Iwase","year":"2021","journal-title":"Langmuir"},{"key":"2023060912180744400_ozad030-B8","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.ultramic.2013.03.002","article-title":"In-situ SEM microchip setup for electrochemical experiments with water based solutions","volume":"129","author":"Jensen","year":"2013","journal-title":"Ultramicroscopy"},{"key":"2023060912180744400_ozad030-B9","doi-asserted-by":"crossref","first-page":"17233","DOI":"10.1021\/jp1044546","article-title":"Scanning electron microscopy for in situ monitoring of semiconductor-liquid interfacial processes: Electron assisted reduction of Ag ions from aqueous solution on the surface of TiO2 rutile nanowire","volume":"114","author":"Kolmakova","year":"2010","journal-title":"J Phys Chem C"},{"key":"2023060912180744400_ozad030-B10","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1021\/acsnano.5b03970","article-title":"Electron microscopy of living cells during in situ fluorescence microscopy","volume":"10","author":"Liv","year":"2016","journal-title":"ACS Nano"},{"key":"2023060912180744400_ozad030-B11","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1083\/jcb.201304193","article-title":"Cryo-electron tomography: The challenge of doing structural biology in situ","volume":"202","author":"Lucic","year":"2013","journal-title":"J Cell Biol"},{"key":"2023060912180744400_ozad030-B12","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1007\/s00216-008-2076-y","article-title":"Development and certification of the new NIES CRM 28: Urban aerosols for the determination of multielements","volume":"391","author":"Mori","year":"2008","journal-title":"Anal Bioanal Chem"},{"key":"2023060912180744400_ozad030-B13","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S0169-1317(00)00016-8","article-title":"Traditional and new applications for kaolin, smectite, and palygorskite: A general overview","volume":"17","author":"Murray","year":"2000","journal-title":"Appl Clay Sci"},{"key":"2023060912180744400_ozad030-B14","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/j.jsb.2010.01.005","article-title":"Atmospheric scanning electron microscope observes cells and tissues in open medium through silicon nitride film","volume":"169","author":"Nishiyama","year":"2010","journal-title":"J Struct Biol"},{"key":"2023060912180744400_ozad030-B15","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0046904","article-title":"High-contrast observation of unstained proteins and viruses by scanning electron microscopy","volume":"7","author":"Ogura","year":"2012","journal-title":"PLoS One"},{"key":"2023060912180744400_ozad030-B16","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0092780","article-title":"Direct observation of unstained biological specimens in water by the frequency transmission electric-field method using SEM","volume":"9","author":"Ogura","year":"2014","journal-title":"PLoS One"},{"key":"2023060912180744400_ozad030-B17","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.bbrc.2015.02.140","article-title":"Nanoscale analysis of unstained biological specimens in water without radiation damage using high-resolution frequency transmission electric-field system based on FE-SEM","volume":"459","author":"Ogura","year":"2015","journal-title":"Biochem Biophys Res Commun"},{"key":"2023060912180744400_ozad030-B18","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1016\/j.bbrc.2017.08.004","article-title":"Nanoscale observation of the natural structure of milk-fat globules and casein micelles in the liquid condition using a scanning electron assisted dielectric microscopy","volume":"491","author":"Ogura","year":"2017","journal-title":"Biochem Biophys Res Commun"},{"key":"2023060912180744400_ozad030-B19","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1038\/s41598-020-80546-0","article-title":"Nanoscale observation of PM2.5 incorporated into mammalian cells using scanning electron-assisted dielectric microscope","volume":"11","author":"Okada","year":"2021","journal-title":"Sci Rep"},{"key":"2023060912180744400_ozad030-B20","doi-asserted-by":"crossref","first-page":"29169","DOI":"10.1038\/srep29169","article-title":"Nanoscale imaging of untreated mammalian cells in a medium with low radiation damage using scanning electron-assisted dielectric microscopy","volume":"6","author":"Okada","year":"2016","journal-title":"Sci Rep"},{"key":"2023060912180744400_ozad030-B21","doi-asserted-by":"crossref","first-page":"43025","DOI":"10.1038\/srep43025","article-title":"High-resolution imaging of living mammalian cells bound by nanobeads-connected antibodies in a medium using scanning electron-assisted dielectric microscopy","volume":"7","author":"Okada","year":"2017","journal-title":"Sci Rep"},{"issue":"Suppl 3","key":"2023060912180744400_ozad030-B22","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1017\/S1431927615002007","article-title":"Reduction of electron scattering image blur for atmospheric scanning electron microscopy","volume":"21","author":"Ominami","year":"2015","journal-title":"Microsc Microanal"},{"key":"2023060912180744400_ozad030-B23","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-540-38967-5","volume-title":"Scanning Electron Microscopy: Physics of Image Formation and Microanalysis","author":"Reimer","year":"1998","edition":"2nd ed."},{"key":"2023060912180744400_ozad030-B24","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/sca.4950030105","article-title":"Measuring the backscattering coefficient and secondary electron yield inside a scanning electron microscope","volume":"3","author":"Reimer","year":"1980","journal-title":"Scanning"},{"key":"2023060912180744400_ozad030-B25","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1038\/nature01513","article-title":"From words to literature in structural proteomics","volume":"422","author":"Sali","year":"2003","journal-title":"Nature"},{"key":"2023060912180744400_ozad030-B26","doi-asserted-by":"crossref","first-page":"6068","DOI":"10.1038\/ncomms7068","article-title":"Growth dynamics and gas transport mechanism of nanobubbles in graphene liquid cells","volume":"6","author":"Shin","year":"2015","journal-title":"Nat Commun"},{"key":"2023060912180744400_ozad030-B27","doi-asserted-by":"crossref","first-page":"8452","DOI":"10.1021\/ja960884f","article-title":"Charge screening and the dielectric constant of proteins: Insights from molecular dynamics","volume":"118","author":"Simonson","year":"1996","journal-title":"J Am Chem Soc"},{"key":"2023060912180744400_ozad030-B28","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s10585-008-9163-5","article-title":"A highly bone marrow metastatic murine breast cancer model established through in vivo selection exhibits enhanced anchorage-independent growth and cell migration mediated by ICAM-1","volume":"25","author":"Takahashi","year":"2008","journal-title":"Clin Exp Metastas"},{"key":"2023060912180744400_ozad030-B29","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1007\/s10585-009-9281-8","article-title":"Chemokine CCL2\/MCP-1 negatively regulates metastasis in a highly bone marrow-metastatic mouse breast cancer model","volume":"26","author":"Takahashi","year":"2009","journal-title":"Clin Exp Metastas"},{"key":"2023060912180744400_ozad030-B30","doi-asserted-by":"crossref","first-page":"3346","DOI":"10.1073\/pnas.0400088101","article-title":"Scanning electron microscopy of cells and tissues under fully hydrated conditions","volume":"101","author":"Thiberge","year":"2004","journal-title":"Proc Natl Acad Sci U S A"},{"key":"2023060912180744400_ozad030-B31","doi-asserted-by":"crossref","first-page":"7384","DOI":"10.1038\/ncomms8384","article-title":"Graphene-enabled electron microscopy and correlated super-resolution microscopy of wet cells","volume":"6","author":"Wojcik","year":"2015","journal-title":"Nat Commun"},{"key":"2023060912180744400_ozad030-B32","article-title":"Clean transfer of large graphene single crystals for high-intactness suspended membranes and liquid cells","volume":"29","author":"Zhang","year":"2017","journal-title":"Adv Mater"}],"container-title":["Microscopy and Microanalysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/mam\/article-pdf\/29\/3\/1037\/50554194\/ozad030.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/mam\/article-pdf\/29\/3\/1037\/50554194\/ozad030.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,9]],"date-time":"2023-06-09T12:21:10Z","timestamp":1686313270000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/mam\/article\/29\/3\/1037\/7078179"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,15]]},"references-count":32,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,3,15]]},"published-print":{"date-parts":[[2023,6,9]]}},"URL":"https:\/\/doi.org\/10.1093\/micmic\/ozad030","relation":{},"ISSN":["1431-9276","1435-8115"],"issn-type":[{"value":"1431-9276","type":"print"},{"value":"1435-8115","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,6]]},"published":{"date-parts":[[2023,3,15]]}}}