{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T08:49:35Z","timestamp":1790412575438,"version":"4.1.0"},"reference-count":13,"publisher":"Oxford University Press (OUP)","issue":"Supplement_1","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"DOI":"10.13039\/100000002","name":"NIH","doi-asserted-by":"publisher","award":["#1R42HD097827\u201301A1"],"award-info":[{"award-number":["#1R42HD097827\u201301A1"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,1,25]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n               <jats:sec>\n                  <jats:title>Introduction<\/jats:title>\n                  <jats:p>People with partial hand loss represent the largest population of upper limb amputees by a factor of 10. The available prosthetic componentry for people with digit loss provide various methods of control, kinematic designs, and functional abilities. Here, the Point Digit II is empirically tested and a discussion is provided comparing the Point Digit II with the existing commercially available prosthetic fingers.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Materials and Methods<\/jats:title>\n                  <jats:p>Benchtop mechanical tests were performed using prototype Point Digit II prosthetic fingers. The battery of tests included a static load test, a static mounting tear-out test, a dynamic load test, and a dynamic cycle test. These tests were implemented to study the mechanisms within the digit and the ability of the device to withstand heavy-duty use once out in the field.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>The Point Digit II met or exceeded all geometric and mechanical specifications. The device can withstand over 300 lbs of force applied to the distal phalange and was cycled over 250,000 times without an adverse event representing 3 years of use. Multiple prototypes were utilized across all tests to confirm the ability to reproduce the device in a reliable manner.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>The Point Digit II presents novel and exciting features to help those with partial hand amputation return to work and regain ability. The use of additive manufacturing, unique mechanism design, and clinically relevant design features provides both the patient and clinician with a prosthetic digit, which improves upon the existing devices available.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/milmed\/usaa258","type":"journal-article","created":{"date-parts":[[2021,1,26]],"date-time":"2021-01-26T01:49:20Z","timestamp":1611625760000},"page":"674-680","source":"Crossref","is-referenced-by-count":11,"title":["The Point Digit II: Mechanical Design and Testing of a Ratcheting Prosthetic Finger"],"prefix":"10.1093","volume":"186","author":[{"given":"Jacob L","family":"Segil","sequence":"first","affiliation":[{"name":"Engineering Plus Program, University of Colorado Boulder, Boulder, CO 80309, USA"},{"name":"Point Designs LLC, Lafayette, CO 80026, USA"},{"name":"Rehabilitation Research and Development Service, Rocky Mountain Regional VA Medical Center, Aurora, CO 80045, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ben","family":"Pulver","sequence":"additional","affiliation":[{"name":"Point Designs LLC, Lafayette, CO 80026, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Huddle","sequence":"additional","affiliation":[{"name":"Point Designs LLC, Lafayette, CO 80026, USA"},{"name":"Department of Bioengineering, University of Colorado Denver-Anschutz Medical Campus, Aurora, CO 80045, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard F ff","family":"Weir","sequence":"additional","affiliation":[{"name":"Point Designs LLC, Lafayette, CO 80026, USA"},{"name":"Department of Bioengineering, University of Colorado Denver-Anschutz Medical Campus, Aurora, CO 80045, USA"},{"name":"Rehabilitation Research and Development Service, Rocky Mountain Regional VA Medical Center, Aurora, CO 80045, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Levin","family":"Sliker","sequence":"additional","affiliation":[{"name":"Point Designs LLC, Lafayette, CO 80026, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2021,1,25]]},"reference":[{"key":"2021032012042895400_R1","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.apmr.2007.11.005","article-title":"Estimating the prevalence of limb loss in the United States: 2005 to 2050","volume":"89","author":"Ziegler-Graham","year":"2008","journal-title":"Arch Phys Med Rehabil"},{"key":"2021032012042895400_R2","article-title":"Disability in the United States: prevalence and causes, 1992.","volume-title":"Disability Statistics, Report 7","author":"LaPlante","year":"1996"},{"key":"2021032012042895400_R3","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/j.pmrj.2009.04.012","article-title":"Changes for the new AMA guides to impairment ratings: implications and applications for physician disability evaluations","volume":"1","author":"Rondinelli","year":"2009","journal-title":"PM&R"},{"key":"2021032012042895400_R4","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1080\/03093640208726646","article-title":"Psychological issues in prosthetic and orthotic practice: a 25 year review of psychology in Prosthetics and Orthotics International","volume":"26","author":"Desmond","year":"2002","journal-title":"Prosthet Orthot Int"},{"key":"2021032012042895400_R5","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1192\/bjp.127.3.204","article-title":"Psycho-social transitions: comparison between reactions to loss of a limb and loss of a spouse","volume":"127","author":"Parkes","year":"1975","journal-title":"Br J Psychiatry"},{"key":"2021032012042895400_R6","volume-title":"Atlas of Amputations and Limb Deficiencies: Surgical, Prosthetic, and Rehabilitation Principles","author":"Krajbich","year":"2016"},{"key":"2021032012042895400_R7","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1080\/09638280701320763","article-title":"Partial hand amputation and work","volume":"29","author":"Burger","year":"2007","journal-title":"Disabil Rehabil"},{"key":"2021032012042895400_R8","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1177\/0309364615596064","article-title":"Impact of silicone prosthesis on hand function, grip power and grip-force tracking ability after finger amputation","volume":"40","author":"Kuret","year":"2016","journal-title":"Prosthet Orthot Int"},{"key":"2021032012042895400_R9","first-page":"52","article-title":"An overview of finger and partial-hand prostheses","volume":"20","author":"Rotter","year":"2010","journal-title":"in Motion"},{"key":"2021032012042895400_R10","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1080\/17483100701714733","article-title":"Consumer design priorities for upper limb prosthetics","volume":"2","author":"Biddiss","year":"2007","journal-title":"Disabil Rehabil Assist Technol"},{"key":"2021032012042895400_R11","first-page":"40","article-title":"The expanding options of partial hand prostheses","volume":"14","author":"Stevens","year":"2015","journal-title":"Orthot Prosthet Edge"},{"key":"2021032012042895400_R12","first-page":"118","article-title":"Guidelines for standards for externally powered hands","volume":"10","author":"Peizer","year":"1969","journal-title":"Bull Prosthet Res"},{"key":"2021032012042895400_R13","volume-title":"Henry Dreyfuss Associates: The Measure of Man and Woman: Human Factors in Design","author":"Tilley","year":"2001"}],"container-title":["Military Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/milmed\/article-pdf\/186\/Supplement_1\/674\/36648049\/usaa258.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/milmed\/article-pdf\/186\/Supplement_1\/674\/36648049\/usaa258.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,20]],"date-time":"2021-03-20T12:04:52Z","timestamp":1616241892000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/milmed\/article\/186\/Supplement_1\/674\/6119519"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,1]]},"references-count":13,"journal-issue":{"issue":"Supplement_1","published-online":{"date-parts":[[2021,1,25]]},"published-print":{"date-parts":[[2021,1,25]]}},"URL":"https:\/\/doi.org\/10.1093\/milmed\/usaa258","relation":{},"ISSN":["0026-4075","1930-613X"],"issn-type":[{"value":"0026-4075","type":"print"},{"value":"1930-613X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,1,1]]},"published":{"date-parts":[[2021,1,1]]}}}