{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:27:01Z","timestamp":1787009221118,"version":"build-2736575974"},"reference-count":26,"publisher":"Oxford University Press (OUP)","issue":"Supplement_3","license":[{"start":{"date-parts":[[2024,8,19]],"date-time":"2024-08-19T00:00:00Z","timestamp":1724025600000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"DOI":"10.13039\/100016156","name":"U.S. Army Medical Research and Development Command","doi-asserted-by":"publisher","award":["W81XWH-22-9-0016"],"award-info":[{"award-number":["W81XWH-22-9-0016"]}],"id":[{"id":"10.13039\/100016156","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100021976","name":"Medical Technology Enterprise Consortium","doi-asserted-by":"publisher","award":["MTEC-22-02-MPAI-061"],"award-info":[{"award-number":["MTEC-22-02-MPAI-061"]}],"id":[{"id":"10.13039\/100021976","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100016156","name":"U.S. Army Medical Research and Development Command","doi-asserted-by":"publisher","award":["W81XWH-22-9-0016"],"award-info":[{"award-number":["W81XWH-22-9-0016"]}],"id":[{"id":"10.13039\/100016156","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100021976","name":"Medical Technology Enterprise Consortium","doi-asserted-by":"publisher","award":["MTEC-22-02-MPAI-061"],"award-info":[{"award-number":["MTEC-22-02-MPAI-061"]}],"id":[{"id":"10.13039\/100021976","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,19]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Musculoskeletal injuries (MSKIs) among active duty soldiers result in more than 10 million limited duty days each year and account for more than 70% of the medically nondeployable population. Overuse injuries in lower limbs from running, foot marching long distances with heavy loads, and lifting heavy objects are the most common types of injuries in the military. Physical training and rehabilitation exercises for greater resiliency through aerobic, muscle strength, endurance, and agility conditioning programs can prevent or reduce the effects of MSKIs if Soldiers adhere to proper biomechanics and training techniques. We are introducing a three-dimensional (3D) camera-based platform for Optical Screening and Conditioning for Injury Resilience (OSCIR) that is designed to identify and correct high-risk movement patterns based on quantifiable biomechanical measurements in clinical or field settings. Our goal is to improve resilience to MSKI by offering greater access to quality of movement skills in warfighters through an autonomous device that can be used in Sports Medicine and Reconditioning Team (SMART) clinics and High-Intensity Tactical Training (HITT) sites.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>OSCIR fuses four pairs of Kinect Azure cameras into a concise footprint to achieve suitable sampling rates and an unobstructed field of view for accurate dynamic movement tracking using a custom point cloud solution. We designed a unique multistage 3D joint tracking algorithm architecture to methodically isolate the human body point cloud from the background, identify individual limb segments, and perform iterative joint optimization at the global and local joint levels. We evaluated the feasibility of our prototype system among N\u2009=\u200912 control participants (6\u2009M\/6\u2009F; 21-37\u2009years) in compliance with the Western Institutional Review Board (Tracking #20225920, approved on November 4, 2022). Five task-specific MSKI outcome metrics identified by end-user physical therapists and athletic trainers as indicators for movement quality were assessed across 7 lower-extremity exercises derived from standardized MSK assessment\/conditioning batteries used in the military. Data were recorded concurrently by OSCIR and a reference standard Vicon motion capture system for validating system accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Task-specific MSKI indicators for knee flexion and hip flexion range of motion achieved an average error of 4.05\u2009\u00b1\u20092.34\u00b0, while 3D position-based postural outcomes of left-right foot distance, left-right hand distance, and step length obtained mean absolute errors of 2.58\u2009\u00b1\u20092.30\u2009cm. Results support the feasibility of our system in achieving outcomes that are comparable to currently accepted laboratory standards.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our study describes the integration process for a 3D camera-based clinical system for MSKI conditioning and rehabilitation. The impact of our system will enable key stakeholders in the military to manage MSKIs in warfighters by automating key assessment and rehabilitation test batteries; making tests more readily accessible, and interpretations more accurate by providing objective biomechanical measures. OSCIR is undergoing turn-key design features to serve as a screening tool for warfighters to readily assess susceptibility to MSKI or as a training platform to help guide exercise techniques to achieve resiliency against future injuries.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/milmed\/usae231","type":"journal-article","created":{"date-parts":[[2024,4,20]],"date-time":"2024-04-20T04:33:18Z","timestamp":1713587598000},"page":"677-685","source":"Crossref","is-referenced-by-count":2,"title":["Platform Design for Optical Screening and Conditioning for Injury Resilience"],"prefix":"10.1093","volume":"189","author":[{"given":"Bhawna","family":"Shiwani","sequence":"first","affiliation":[{"name":"Altec Inc , Natick, MA 01760,","place":["USA"]},{"name":"Delsys Inc , Natick, MA 01760,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amy","family":"Silder","sequence":"additional","affiliation":[{"name":"Naval Health Research Center , San Diego, CA 92106,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alaina","family":"Tulskie","sequence":"additional","affiliation":[{"name":"Altec Inc , Natick, MA 01760,","place":["USA"]},{"name":"Delsys Inc , Natick, MA 01760,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dalya","family":"Al-Mfarej","sequence":"additional","affiliation":[{"name":"Altec Inc , Natick, MA 01760,","place":["USA"]},{"name":"Delsys Inc , Natick, MA 01760,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Green","sequence":"additional","affiliation":[{"name":"Naval Health Research Center , San Diego, CA 92106,","place":["USA"]},{"name":"Leidos, Inc. , San Diego, CA 92121,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serge H","family":"Roy","sequence":"additional","affiliation":[{"name":"Altec Inc , Natick, MA 01760,","place":["USA"]},{"name":"Delsys Inc , Natick, MA 01760,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca De","family":"Luca","sequence":"additional","affiliation":[{"name":"Altec Inc , Natick, MA 01760,","place":["USA"]},{"name":"Delsys Inc , Natick, MA 01760,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pinata H","family":"Sessoms","sequence":"additional","affiliation":[{"name":"Naval Health Research Center , San Diego, CA 92106,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6523-5527","authenticated-orcid":false,"given":"Joshua","family":"Kline","sequence":"additional","affiliation":[{"name":"Altec Inc , Natick, MA 01760,","place":["USA"]},{"name":"Delsys Inc , Natick, MA 01760,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,8,17]]},"reference":[{"key":"2025081620015408300_R1","article-title":"Health of the Force","author":"Ambrose","year":"2022"},{"issue":"1 Suppl","key":"2025081620015408300_R2","doi-asserted-by":"publisher","first-page":"S42","DOI":"10.1016\/j.amepre.2009.10.014","article-title":"Medical surveillance of injuries in the US Military descriptive epidemiology and recommendations for improvement","volume":"38","author":"Jones","year":"2010","journal-title":"Am J Prev Med"},{"issue":"Suppl 11","key":"2025081620015408300_R3","doi-asserted-by":"publisher","first-page":"S57","DOI":"10.1519\/JSC.0000000000001115","article-title":"Physical training, fitness, and injuries: lessons learned from military studies","volume":"29","author":"Jones","year":"2015","journal-title":"Jscr"},{"key":"2025081620015408300_R4","article-title":"Technical Information Paper (TIP) 12-054-0616: Foot marching, load carriage, and injury risk","author":"Army Public Health Command","year":"2016"},{"issue":"6","key":"2025081620015408300_R5","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1519\/JSC.0000000000002382","article-title":"Systematic review of the association between physical fitness and musculoskeletal injury risk: part 3-flexibility, power, speed, balance, and agility","volume":"33","author":"de la Motte","year":"2019","journal-title":"J Strength Cond Res"},{"issue":"12","key":"2025081620015408300_R6","doi-asserted-by":"publisher","first-page":"3571","DOI":"10.1519\/JSC.0000000000000556","article-title":"Efficacy of the functional movement screen: a review","volume":"28","author":"Kraus","year":"2014","journal-title":"J Strength Cond Res"},{"issue":"5","key":"2025081620015408300_R7","doi-asserted-by":"publisher","first-page":"1190","DOI":"10.26603\/001c.27634","article-title":"Systematic review and meta-analysis of the y-balance test lower quarter: reliability, discriminant validity, and predictive validity","volume":"16","author":"Plisky","year":"2021","journal-title":"Int J Sports Phys Ther"},{"issue":"11","key":"2025081620015408300_R8","doi-asserted-by":"publisher","first-page":"3146","DOI":"10.1519\/JSC.0000000000001792","article-title":"Effect of a lower extremity preventive training program on physical performance scores in military recruits","volume":"31","author":"Peck","year":"2017","journal-title":"J Strength Cond Res"},{"key":"2025081620015408300_R9","article-title":"Melbourne ACL Rehabilitation Guide 2.0","author":"Cooper"},{"issue":"9","key":"2025081620015408300_R10","doi-asserted-by":"publisher","DOI":"10.3390\/agronomy11091780","article-title":"Evaluation of depth cameras for use in fruit localization and sizing: finding a successor to Kinect v2","volume":"11","author":"Neupane","year":"2021","journal-title":"Agronomy"},{"key":"2025081620015408300_R11","first-page":"143","article-title":"Colored point cloud registration revisited","author":"Park","year":"2017"},{"issue":"22","key":"2025081620015408300_R12","doi-asserted-by":"publisher","DOI":"10.3390\/s22228900","article-title":"Spatio-temporal calibration of multiple kinect cameras using 3D human pose","volume":"22","author":"Eichler","year":"2022","journal-title":"Sensors"},{"issue":"6","key":"2025081620015408300_R13","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1145\/358669.358692","article-title":"Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography","volume":"24","author":"Fischler","year":"1981","journal-title":"Commun. ACM"},{"key":"2025081620015408300_R14","doi-asserted-by":"publisher","DOI":"10.48550\/arXiv.1906.08172","article-title":"Mediapipe: a framework for building perception pipelines","author":"Lugaresi","year":"2019"},{"issue":"10","key":"2025081620015408300_R15","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1007\/s001700170119","article-title":"Data reduction methods for reverse engineering","volume":"17","author":"Lee","year":"2001","journal-title":"Int J Adv Manuf Technol"},{"issue":"5","key":"2025081620015408300_R16","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1109\/JPROC.2018.2820126","article-title":"Graph signal processing: overview, challenges, and applications","volume":"106","author":"Ortega","year":"2018","journal-title":"Proc IEEE"},{"issue":"1","key":"2025081620015408300_R17","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1109\/LSP.2020.3023587","article-title":"Hypergraph spectral clustering for Point Cloud segmentation","volume":"27","author":"Zhang","year":"2020","journal-title":"IEEE Signal Process Lett"},{"issue":"9","key":"2025081620015408300_R18","doi-asserted-by":"publisher","DOI":"10.3390\/s22093155","article-title":"Markerless 3D skeleton tracking algorithm by merging multiple inaccurate skeleton data from multiple RGB-D sensors","volume":"22","author":"Lee","year":"2022","journal-title":"Sensors (Basel)"},{"key":"2025081620015408300_R19","article-title":"Markerless Motion Capture Redefined","author":"Theia Markerless"},{"issue":"18","key":"2025081620015408300_R20","doi-asserted-by":"publisher","DOI":"10.3390\/s20185104","article-title":"Evaluation of the pose tracking performance of the Azure Kinect and Kinect v2 for gait analysis in comparison with a gold standard: a pilot study","volume":"20","author":"Albert","year":"2020","journal-title":"Sensors"},{"issue":"7","key":"2025081620015408300_R21","doi-asserted-by":"publisher","DOI":"10.3390\/s17071591","article-title":"A study of Vicon system positioning performance","volume":"17","author":"Merriaux","year":"2017","journal-title":"Sensors"},{"issue":"1","key":"2025081620015408300_R22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40634-018-0161-5","article-title":"Accuracy and reliability of knee goniometry methods","volume":"5","author":"Hancock","year":"2018","journal-title":"J Exp Orthop"},{"issue":"3","key":"2025081620015408300_R23","doi-asserted-by":"publisher","first-page":"66","DOI":"10.17511\/ijoso.2017.i03.03","article-title":"Reliability of goniometry to determine the hip range of motion","volume":"3","author":"Bhamare","year":"2017","journal-title":"Surg Update"},{"issue":"Oct","key":"2025081620015408300_R24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsampl.2022.100001","article-title":"Markerless motion capture: what clinician-scientists need to know right now","volume":"1","author":"Ito","year":"2022","journal-title":"JSAMS Plus"},{"issue":"Jul","key":"2025081620015408300_R25","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.gaitpost.2023.05.029","article-title":"Comparison of kinematics between Theia markerless and conventional marker-based gait analysis in clinical patients","volume":"104","author":"Wren","year":"2023","journal-title":"Gait Posture"},{"issue":"24","key":"2025081620015408300_R26","doi-asserted-by":"publisher","DOI":"10.3390\/s22249819","article-title":"Agreement between Azure Kinect and marker-based motion analysis during functional movements: a feasibility study","volume":"22","author":"Jo","year":"2022","journal-title":"Sensors"}],"container-title":["Military Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/189\/Supplement_3\/677\/58855520\/usae231.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/189\/Supplement_3\/677\/58855520\/usae231.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,17]],"date-time":"2025-08-17T00:01:58Z","timestamp":1755388918000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/milmed\/article\/189\/Supplement_3\/677\/7735890"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,17]]},"references-count":26,"journal-issue":{"issue":"Supplement_3","published-online":{"date-parts":[[2024,8,17]]},"published-print":{"date-parts":[[2024,8,19]]}},"URL":"https:\/\/doi.org\/10.1093\/milmed\/usae231","relation":{},"ISSN":["0026-4075","1930-613X"],"issn-type":[{"value":"0026-4075","type":"print"},{"value":"1930-613X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,9]]},"published":{"date-parts":[[2024,8,17]]}}}