{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T23:10:29Z","timestamp":1778022629315,"version":"3.51.4"},"reference-count":30,"publisher":"Oxford University Press (OUP)","issue":"5-6","funder":[{"name":"U.S. Army Medical Research and Development Command: Combat Casualty Care Research Program","award":["CO220054"],"award-info":[{"award-number":["CO220054"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Most potentially survivable combat deaths occur from hemorrhage. With the future potential for large scale combat operations, surgical treatment of wounded combatants will be delayed, necessitating prolonged prehospital care. We tested whether 6 hemostatic dressings could control junctional hemorrhage for up to 24 hours.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Female Yorkshire swine were randomized into 9 groups: no intervention, non-hemostatic control gauze, Combat Gauze, Celox Gauze, ChitoGauze, Celox Rapid, Veriset, and CounterFlow Gauze.<\/jats:p>\n                    <jats:p>Following anesthesia, the femoral artery received arteriotomy, and a 45 second uncontrolled hemorrhage before treatment was applied. Animals were monitored for up to 24 hour or until euthanasia criteria were met. If the first 3 animals receiving each treatment did not survive 2 hour, the baseline survival threshold was not met and additional animals were not performed. Primary outcomes were survival time and 24 hour survival rate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All animals without intervention died (&amp;lt;30 minutes). Only Combat Gauze, Celox Gauze, Celox Rapid, and Veriset groups met the survival threshold and included 5 animals. Ranking by survival time was Veriset (19.4\u2009\u00b1\u200910.3 hour), Combat Gauze (16.7\u2009\u00b1\u200910.5 hour), Celox Gauze (15.1\u2009\u00b1\u200912.2 hour), and Celox Rapid (14.9\u2009\u00b1\u200912.4 hour). Veriset achieved 80% survival rate although each of the other 3 groups were 60%. Post-treatment estimated blood loss was least in Veriset (1.0% of body weight) and greatest in Celox Gauze (2.0%) groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In this pilot study, Combat Gauze, Celox Gauze, Veriset, and Celox Rapid achieved survival beyond 2 hour in a fatal junctional wound. These should be considered for use in casualties with junctional hemorrhage especially under conditions requiring prolonged prehospital care<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/milmed\/usaf490","type":"journal-article","created":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T11:51:43Z","timestamp":1758973903000},"page":"e931-e937","source":"Crossref","is-referenced-by-count":1,"title":["Assessment of Hemostatic Dressings for Compressible Wounds in a Swine Model Simulating Prolonged Field Care"],"prefix":"10.1093","volume":"191","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-2416-7262","authenticated-orcid":false,"given":"Zachary","family":"Booms","sequence":"first","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3135-3653","authenticated-orcid":false,"given":"Jesse Q","family":"Nguyen","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Smith","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-2400-0387","authenticated-orcid":false,"given":"Simon","family":"Milne","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Irasema","family":"Terrazas","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Barraza","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tiffany","family":"Geisen","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Colin","family":"Perry","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luciana","family":"Torres","sequence":"additional","affiliation":[{"name":"59th Medical Wing , , Lackland Air Force Base, TX,","place":["United States"]},{"name":"ST Office of the Chief Scientist , , Lackland Air Force Base, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1706-9536","authenticated-orcid":false,"given":"Thomas","family":"Edwards","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie M","family":"Lipiec","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Cap","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kathy L","family":"Ryan","sequence":"additional","affiliation":[{"name":"United States Army Institute of Surgical Research, Department of Hemorrhage Control and Vascular Dysfunction , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan D","family":"Stallings","sequence":"additional","affiliation":[{"name":"Joint Trauma System , , Fort Sam Houston, TX,","place":["United States"]},{"name":"Operations (J-3), Strategy (J-5), Education and Training (J-7) , , Fort Sam Houston, TX,","place":["United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,4,18]]},"reference":[{"key":"2026050517472851500_usaf490-B1","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1097\/01.ta.0000199961.02677.19","article-title":"Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations","volume":"60","author":"Kauvar","year":"2006","journal-title":"J Trauma"},{"key":"2026050517472851500_usaf490-B2","doi-asserted-by":"publisher","first-page":"S431","DOI":"10.1097\/TA.0b013e3182755dcc","article-title":"Death on the battlefield (2001-2011): implications for the future of combat casualty care","volume":"73","author":"Eastridge","year":"2012","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B3","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1136\/military-2023-002451","article-title":"Abdominal aortic junctional tourniquet (AAJT-S): a systematic review of utility in military practice","volume":"171","author":"Webster","year":"2025","journal-title":"BMJ Mil Health"},{"key":"2026050517472851500_usaf490-B4","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.jss.2018.05.017","article-title":"Long-term consequences of abdominal aortic and junctional tourniquet for hemorrhage control","volume":"231","author":"Kheirabadi","year":"2018","journal-title":"J Surg Res"},{"key":"2026050517472851500_usaf490-B5","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1097\/TA.0000000000002013","article-title":"Abdominal aortic and junctional tourniquet release after 240 minutes is survivable and associated with small intestine and liver ischemia after porcine class II hemorrhage","volume":"85","author":"Brannstrom","year":"2018","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B6","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1186\/s13049-023-01133-6","article-title":"A modified chain-based sponge dressing controls junctional hemorrhage in the tactical combat casualty care simulation of pigs","volume":"31","author":"Wu","year":"2023","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"2026050517472851500_usaf490-B7","doi-asserted-by":"publisher","first-page":"S144","DOI":"10.1097\/TA.0000000000004071","article-title":"Evaluation of novel hemostatic agents in a coagulopathic swine model of junctional hemorrhage","volume":"95","author":"Gerling","year":"2023","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B8","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1097\/TA.0000000000003869","article-title":"A novel sodium polyacrylate-based stasis dressing to treat lethal hemorrhage in a penetrating trauma swine model","volume":"94","author":"Wang","year":"2023","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B9","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1097\/SHK.0000000000000646","article-title":"Self-propelled dressings containing thrombin and tranexamic acid improve short-term survival in a swine model of lethal junctional hemorrhage","volume":"46","author":"Baylis","year":"2016","journal-title":"Shock"},{"key":"2026050517472851500_usaf490-B10","doi-asserted-by":"publisher","first-page":"14608","DOI":"10.1038\/s41598-019-51208-7","article-title":"Evaluation of chitosan-based dressings in a swine model of artery-injury-related shock","volume":"9","author":"Wang","year":"2019","journal-title":"Sci Rep"},{"key":"2026050517472851500_usaf490-B11","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1097\/TA.0000000000003049","article-title":"Trauma patient transport times unchanged despite trauma center proliferation: a 10-year review","volume":"90","author":"Jones","year":"2021","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B12","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1093\/milmed\/usx211","article-title":"A review of casualties transported to role 2 medical treatment facilities in Afghanistan","volume":"183","author":"Kotwal","year":"2018","journal-title":"Mil Med"},{"key":"2026050517472851500_usaf490-B13","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1093\/milmed\/usad110","article-title":"Ruggedized self-propelling hemostatic gauze delivers low dose of thrombin and systemic tranexamic acid and achieves high survival in swine with junctional hemorrhage","volume":"188","author":"Ali-Mohamad","year":"2023","journal-title":"Mil Med"},{"key":"2026050517472851500_usaf490-B14","doi-asserted-by":"publisher","first-page":"100","DOI":"10.55460\/QT3B-XK5B","article-title":"Tactical combat casualty care (TCCC) guidelines: 25 January 2024","volume":"24","author":"Deaton","year":"2024","journal-title":"J Spec Oper Med"},{"key":"2026050517472851500_usaf490-B15","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1038\/s41536-020-00117-9","article-title":"Prolonged field care for traumatic extremity injuries: defining a role for biologically focused technologies","volume":"6","author":"Dolan","year":"2021","journal-title":"NPJ Regen Med"},{"key":"2026050517472851500_usaf490-B16","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1097\/TA.0b013e3181c97ef1","article-title":"Safety evaluation of new hemostatic agents, smectite granules, and kaolin-coated gauze in a vascular injury wound model in swine","volume":"68","author":"Kheirabadi","year":"2010","journal-title":"J Trauma"},{"key":"2026050517472851500_usaf490-B17","doi-asserted-by":"publisher","first-page":"S150","DOI":"10.1097\/TA.0b013e318299d909","article-title":"Comparison of novel hemostatic dressings with QuikClot combat gauze in a standardized swine model of uncontrolled hemorrhage","volume":"75","author":"Rall","year":"2013","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B18","doi-asserted-by":"publisher","first-page":"64","DOI":"10.55460\/RAYH-IZJP","article-title":"Evaluation of XSTAT(R) and QuickClot(R) Combat gauze(R) in a swine model of lethal junctional hemorrhage in coagulopathic swine","volume":"17","author":"Cox","year":"2017","journal-title":"J Spec Oper Med"},{"key":"2026050517472851500_usaf490-B19","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1016\/j.amjsurg.2013.01.014","article-title":"Chitosan based advanced hemostatic dressing is associated with decreased blood loss in a swine uncontrolled hemorrhage model","volume":"205","author":"Kunio","year":"2013","journal-title":"Am J Surg"},{"key":"2026050517472851500_usaf490-B20","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1111\/hpb.12009","article-title":"A multicentre, randomized clinical trial comparing the veriset haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery","volume":"15","author":"\u00d6llinger","year":"2013","journal-title":"HPB (Oxford)"},{"key":"2026050517472851500_usaf490-B21","doi-asserted-by":"publisher","first-page":"65","DOI":"10.2147\/MDER.S145651","article-title":"A randomized, controlled trial of veriset hemostatic patch in halting cardiovascular bleeding","volume":"11","author":"Glineur","year":"2018","journal-title":"Med Devices (Auckl)"},{"key":"2026050517472851500_usaf490-B22","doi-asserted-by":"publisher","first-page":"S86","DOI":"10.1097\/TA.0000000000003670","article-title":"Percutaneous delivery of self-propelling thrombin-containing powder increases survival from noncompressible truncal hemorrhage in a swine model of coagulopathy and hypothermia","volume":"93","author":"Cau","year":"2022","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B23","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1016\/j.injury.2022.01.024","article-title":"Percutaneous delivery of self-propelling hemostatic powder for managing non-compressible abdominal hemorrhage: a proof-of-concept study in swine","volume":"53","author":"Cau","year":"2022","journal-title":"Injury"},{"key":"2026050517472851500_usaf490-B24","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1093\/milmed\/usaa403","article-title":"Efficacy of hemostatic gauzes in a swine model of prolonged field care with limb movement","volume":"186","author":"Landers","year":"2021","journal-title":"Mil Med"},{"key":"2026050517472851500_usaf490-B25","doi-asserted-by":"publisher","first-page":"S139","DOI":"10.1097\/TA.0b013e318221931e","article-title":"Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents","volume":"71","author":"Kheirabadi","year":"2011","journal-title":"J Trauma"},{"key":"2026050517472851500_usaf490-B26","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1097\/TA.0000000000004164","article-title":"Evaluation of hemostatic devices in a randomized porcine model of junctional hemorrhage and 72-hour prolonged field care","volume":"96","author":"Pratt","year":"2024","journal-title":"J Trauma Acute Care Surg"},{"key":"2026050517472851500_usaf490-B27","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.7205\/MILMED-D-14-00541","article-title":"Control of junctional hemorrhage in a consensus swine model with hemostatic gauze products following minimal training","volume":"180","author":"Conley","year":"2015","journal-title":"Mil Med"},{"key":"2026050517472851500_usaf490-B28","doi-asserted-by":"publisher","first-page":"477","DOI":"10.3109\/10903127.2011.598615","article-title":"Comparison of two packable hemostatic gauze dressings in a porcine hemorrhage model","volume":"15","author":"Schwartz","year":"2011","journal-title":"Prehosp Emerg Care"},{"key":"2026050517472851500_usaf490-B29","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1097\/TA.0b013e3181ac0c99","article-title":"Determination of efficacy of new hemostatic dressings in a model of extremity arterial hemorrhage in swine","volume":"67","author":"Kheirabadi","year":"2009","journal-title":"J Trauma"},{"key":"2026050517472851500_usaf490-B30","doi-asserted-by":"publisher","first-page":"126","DOI":"10.55460\/JYLU-4OZ8","article-title":"Fluid resuscitation in tactical combat casualty care; TCCC guidelines change 21-01. 4 November 2021","volume":"21","author":"Deaton","year":"2021","journal-title":"J Spec Oper Med"}],"container-title":["Military Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/191\/5-6\/e931\/64884046\/usaf490.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/191\/5-6\/e931\/64884046\/usaf490.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T22:11:35Z","timestamp":1778019095000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/milmed\/article\/191\/5-6\/e931\/8300396"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,18]]},"references-count":30,"journal-issue":{"issue":"5-6","published-online":{"date-parts":[[2026,4,18]]},"published-print":{"date-parts":[[2026,5,1]]}},"URL":"https:\/\/doi.org\/10.1093\/milmed\/usaf490","relation":{},"ISSN":["0026-4075","1930-613X"],"issn-type":[{"value":"0026-4075","type":"print"},{"value":"1930-613X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,5]]},"published":{"date-parts":[[2026,4,18]]}}}