{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T23:11:07Z","timestamp":1778022667720,"version":"3.51.4"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"5-6","license":[{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"departmental sources only"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>A run test is used in the assessment of physical fitness in military applicants. Seismocardiography is a fast, non-invasive method for estimation of cardiorespiratory fitness which could replace conventional run tests. We aimed to assess the association between distance covered at a 12-minute run test and estimated maximum oxygen uptake using seismocardiography. We hypothesized was that there was a significant correlation between the distance measured at a 12-minute run test and the estimated maximum oxygen uptake determined by seismocardiography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>We included healthy military applicants aged between 18 and 49 years. A 12-minute run test was conducted and we measured the covered distance. Maximum oxygen uptake was estimated by seismocardiography with the Seismofit device at rest in connection with the medical examination. We analyzed the association between the covered run test distance and the estimated maximum oxygen uptake by a correlation analysis. We also calculated an expected run distance in meters by Cooper\u2019s formula based on the estimated maximum oxygen uptake. The expected and measured run distances were compared with Bland-Altman analysis. The study was presented for the Regional Research Ethics Committee who decided that the study could be conducted without formal approval because it was entirely observational.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>We included 219 individuals and complete data were obtained in 204 participants in whom there was a significant correlation between estimated maximum oxygen uptake and the measured 12-minute run distance R\u2009=\u20090.40, P\u2009&amp;lt;\u20090.001. The bias (mean difference) in run distance (expected minus measured) was 155 m, SD 298 m, limits of agreement \u2212429 to 739 m. In women, the mean difference in run distance (expected minus measured) was \u221249 m, SD 226 m while in men, mean difference (expected minus measured) in run distance was 204 m, SD 294 m. There was a significant negative correlation between BMI and the difference (expected minus measured) in run distance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>A significant association was found between distance measured at a 12-minute run test and the estimated maximum oxygen uptake determined by seismocardiography. There was, however, a low precision as we found too high variability in the difference between expected and measured run distance to allow prediction of run distance.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/milmed\/usaf511","type":"journal-article","created":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T11:33:19Z","timestamp":1759750399000},"page":"e1108-e1113","source":"Crossref","is-referenced-by-count":0,"title":["Estimation of Cardiorespiratory Fitness in Military Applicants Using Seismocardiography"],"prefix":"10.1093","volume":"191","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7480-3004","authenticated-orcid":false,"given":"Lars S","family":"Rasmussen","sequence":"first","affiliation":[{"name":"Danish Ministry of Defence Personnal Agency , H.C. Sneedorffs Alle 3 , Copenhagen, DK-1439,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Alstrup","sequence":"additional","affiliation":[{"name":"Danish Ministry of Defence Personnal Agency , H.C. Sneedorffs Alle 3 , Copenhagen, DK-1439,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lise","family":"Markussen","sequence":"additional","affiliation":[{"name":"Danish Ministry of Defence Personnal Agency , H.C. Sneedorffs Alle 3 , Copenhagen, DK-1439,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Trine","family":"Lamberts","sequence":"additional","affiliation":[{"name":"Danish Ministry of Defence Personnal Agency , H.C. Sneedorffs Alle 3 , Copenhagen, DK-1439,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claus","family":"Neumann","sequence":"additional","affiliation":[{"name":"Danish Ministry of Defence Personnal Agency , H.C. Sneedorffs Alle 3 , Copenhagen, DK-1439,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9827-440X","authenticated-orcid":false,"given":"Morten","family":"Lamberts","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Herlev Gentofte Hospital , Borgmester Ib Juuls Vej 1 , Herlev, DK-2730,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,4,17]]},"reference":[{"key":"2026050517481557400_usaf511-B1","doi-asserted-by":"publisher","first-page":"64","DOI":"10.3390\/vibration2010005","article-title":"Recent advances in seismocardiography","volume":"2","author":"Taebi","year":"2019","journal-title":"Vibration"},{"key":"2026050517481557400_usaf511-B2","doi-asserted-by":"publisher","first-page":"15455","DOI":"10.1038\/s41598-018-33675-6","article-title":"Definition of fiducial points in the normal seismocardiogram","volume":"8","author":"S\u00f8rensen","year":"2018","journal-title":"Sci Rep"},{"key":"2026050517481557400_usaf511-B3","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1097\/00005768-200001000-00012","article-title":"Limiting factors for maximum oxygen uptake and determinants of endurance performance","volume":"32","author":"Bassett","year":"2000","journal-title":"Med Sci Sports Exerc"},{"key":"2026050517481557400_usaf511-B4","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.cvdhj.2023.08.020","article-title":"Validity and reliability of seismocardiography for the estimation of cardiorespiratory fitness","volume":"4","author":"Hansen","year":"2023","journal-title":"Cardiovasc Digit Health J"},{"key":"2026050517481557400_usaf511-B5","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1001\/jama.1968.03140030033008","article-title":"A means of assessing maximal oxygen intake. Correlation between field and treadmill testing","volume":"203","author":"Cooper","year":"1968","journal-title":"JAMA"},{"key":"2026050517481557400_usaf511-B6","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"2026050517481557400_usaf511-B7","doi-asserted-by":"publisher","first-page":"1298877","DOI":"10.3389\/fspor.2023.1298877","article-title":"Effects on cardiorespiratory fitness of moderate-intensity training vs. energy-matched training with increasing intensity","volume":"5","author":"Reuter","year":"2023","journal-title":"Front Sports Act Living"},{"key":"2026050517481557400_usaf511-B8","doi-asserted-by":"publisher","first-page":"1682","DOI":"10.1001\/archinte.163.14.1682","article-title":"Cardiorespiratory fitness and the risk of stroke in men","volume":"163","author":"Kurl","year":"2003","journal-title":"Arch Intern Med"},{"key":"2026050517481557400_usaf511-B9","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1186\/s12889-024-17687-8","article-title":"Respiratory patterns and physical fitness in healthy adults: a cross-sectional study","volume":"24","author":"Liang","year":"2024","journal-title":"BMC Public Health"},{"key":"2026050517481557400_usaf511-B10","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1007\/s00421-023-05388-w","article-title":"A verification phase adds little value to the determination of maximum oxygen uptake in well-trained adults","volume":"124","author":"Bruggisser","year":"2024","journal-title":"Eur J Appl Physiol"},{"key":"2026050517481557400_usaf511-B11","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/0002-9149(91)90744-6","article-title":"Seismocardiographic changes associated with obstruction of coronary blood flow during balloon angioplasty","volume":"68","author":"Salerno","year":"1991","journal-title":"Am J Cardiol"},{"key":"2026050517481557400_usaf511-B12","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ad6a67","article-title":"Seismocardiography and echocardiography: the correlation in the systolic complex","volume":"10","author":"Kolind","year":"2024","journal-title":"Biomed Phys Eng Express"},{"key":"2026050517481557400_usaf511-B13","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1055\/a-2004-4669","article-title":"Accuracy of a clinical applicable method for prediction of VO2max using seismocardiography","volume":"44","author":"Hansen","year":"2023","journal-title":"Int J Sports Med"},{"key":"2026050517481557400_usaf511-B14","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1002\/ejsc.12147","article-title":"Accuracy of a non-exercise method using seismocardiography for the estimation of VO2 peak in sub-elite football players","volume":"24","author":"Hansen","year":"2024","journal-title":"Eur J Sport Sci"},{"key":"2026050517481557400_usaf511-B15","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1519\/JSC.0b013e3181cc2423","article-title":"Validity and reliability analysis of Cooper\u2019s 12-minute run and the multistage shuttle run in healthy adults","volume":"25","author":"Penry","year":"2011","journal-title":"J Strength Cond Res"},{"key":"2026050517481557400_usaf511-B16","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.3389\/fphys.2019.01349","article-title":"Cooper test provides better half-marathon performance prediction in recreational runners than laboratory tests","volume":"10","author":"Alvero-Cruz","year":"2019","journal-title":"Front Physiol"},{"key":"2026050517481557400_usaf511-B17","doi-asserted-by":"publisher","first-page":"1746","DOI":"10.1080\/02640414.2021.1898106","article-title":"Estimation of maximal oxygen uptake from the 3,000 m run in adult men and women","volume":"39","author":"Aandstad","year":"2021","journal-title":"J Sports Sci"}],"container-title":["Military Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/191\/5-6\/e1108\/64922702\/usaf511.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/191\/5-6\/e1108\/64922702\/usaf511.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T22:19:29Z","timestamp":1778019569000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/milmed\/article\/191\/5-6\/e1108\/8300770"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,17]]},"references-count":17,"journal-issue":{"issue":"5-6","published-online":{"date-parts":[[2026,4,17]]},"published-print":{"date-parts":[[2026,5,1]]}},"URL":"https:\/\/doi.org\/10.1093\/milmed\/usaf511","relation":{},"ISSN":["0026-4075","1930-613X"],"issn-type":[{"value":"0026-4075","type":"print"},{"value":"1930-613X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,5]]},"published":{"date-parts":[[2026,4,17]]}}}