{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:40:18Z","timestamp":1786120818415,"version":"build-2736575974"},"reference-count":11,"publisher":"Oxford University Press (OUP)","issue":"Supplement_1","funder":[{"DOI":"10.13039\/100016156","name":"U.S. Army Medical Research and Development Command","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100016156","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Normal blood oxygenation (SpO2) is important in the readiness of warfighters at high terrestrial altitudes and high-altitude parachuting operations. A hands-free SpO2 wearable with real-time alerting capability could allow for preventive actions before health or performance is compromised while not interfering with task performance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Prototype headbands were constructed with an embedded sensor that assesses SpO2 and heart rate from the forehead by photoplethysmography. Volunteers (n\u2009=\u200913) wore 12 similarly constructed prototype headbands while completing five minutes of sitting and self-paced treadmill walking and running. Volunteers also completed free living activities for two hours. A survey (Likert-type and open-ended questions) was administered that assessed fit, comfort, impact on activities, impact on the head\/body, durability, and overall acceptability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Overall comfort was rated moderately comfortable: 5.8\u2009\u00b1\u20091.0; 7-point scale (1\u2009=\u2009Very Uncomfortable, 7\u2009=\u2009Extremely Comfortable). Open-ended responses revealed initial comfort was very comfortable, but after two hours the headband became slightly uncomfortable. When examining the impact on daily activities, a score of 5\u2009=\u2009No Negative Impact and 4\u2009=\u2009Slight Negative Impact, a rating of 4.7\u2009\u00b1\u20090.9 was seen. Headband was acceptable to wear for two hours or less, by 69% of volunteers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Regarding operations at high terrestrial altitude, a USARIEM-patented algorithm that uses continuous SpO2 measures provides risk guidance on acute mountain sickness (AMS). Early treatment or actions will help prevent AMS. For the high-altitude jumpers, verification of a healthy SpO2 level before exiting the aircraft is necessary. For both cases the use of the SpO2 headband should lead to safer operations. However, for the wearable to be effective, it needs to be acceptable. These results illustrate that for short-term operations of 2 hours or less, it is acceptable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/milmed\/usag036","type":"journal-article","created":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T12:38:36Z","timestamp":1769258316000},"page":"129-135","source":"Crossref","is-referenced-by-count":0,"title":["Continuous SpO2-Monitoring Headband Is Acceptable for Military Operations"],"prefix":"10.1093","volume":"191","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4882-0011","authenticated-orcid":false,"given":"William J","family":"Tharion","sequence":"first","affiliation":[{"name":"US Army Research Institute of Environmental Medicine , Natick, MA 01760,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauren E","family":"Cantley","sequence":"additional","affiliation":[{"name":"Massachusetts Institute of Technology Lincoln Laboratory , Lexington, MA 02420,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,8,6]]},"reference":[{"key":"2026080621030386600_usag036-B1","doi-asserted-by":"publisher","first-page":"e0210875","DOI":"10.1371\/jourmal.pone.e0210875","article-title":"The value of vital sign trends in predicting and monitoring clinical deterioration: a systematic review","volume":"14","author":"Brekka","year":"2019","journal-title":"PLoS One"},{"key":"2026080621030386600_usag036-B2","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.3390\/s21041263","article-title":"The use of pulse oximetry in the assessment of acclimatization to high altitude","volume":"21","author":"Dunnwalk","year":"2021","journal-title":"Sensors"},{"key":"2026080621030386600_usag036-B3","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1093\/oso\/9780190455132.003.0007","volume-title":"Human Performance Optimization: The Science and Ethics of Enhancing Human Capabilities","author":"Tharion","year":"2019"},{"key":"2026080621030386600_usag036-B4","author":"Tharion","year":"2025"},{"key":"2026080621030386600_usag036-B5","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1109\/titb.2005.854512","article-title":"A wearable health care system based on knitted integrated sensors","volume":"9","author":"Paradiso","year":"2005","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"2026080621030386600_usag036-B6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-9-21","article-title":"A review of wearable sensors and systems with application in rehabilitation","volume":"9","author":"Patel","year":"2012","journal-title":"J Neuroeng Rehabil."},{"key":"2026080621030386600_usag036-B7","author":"Cantley","year":"2021"},{"key":"2026080621030386600_usag036-B8","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1001\/archderm.1988.01670060015008","article-title":"The caliditiy and practicality of sun-reactive skin types I through VI","volume":"124","author":"Fitzpatrick","year":"1988","journal-title":"AMA Arch. Derm"},{"key":"2026080621030386600_usag036-B9","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.hrtlng.2006.07.007","article-title":"Comparison of forehead and digit oximetry in surgical\/trauma patients at risk for decreased peripheral perfusion","volume":"36","author":"Schallom","year":"2007","journal-title":"Heart Lung"},{"key":"2026080621030386600_usag036-B10","first-page":"20","article-title":"Army builds tool to save lives at high altitude","volume":"111","author":"Phillips","year":"2002","journal-title":"Infantry. Winter"},{"key":"2026080621030386600_usag036-B11","doi-asserted-by":"crossref","first-page":"S95","DOI":"10.1016\/j.jsams.2017.09.446","article-title":"Predicting individual risk of altitude illness using real-time monitoring","volume":"20","author":"Beidleman","year":"2017","journal-title":"J Sci Med Sport"}],"container-title":["Military Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/191\/Supplement_1\/129\/70490671\/usag036.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/milmed\/article-pdf\/191\/Supplement_1\/129\/70490671\/usag036.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T01:03:21Z","timestamp":1786064601000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/milmed\/article\/191\/Supplement_1\/129\/8751904"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":11,"journal-issue":{"issue":"Supplement_1","published-online":{"date-parts":[[2026,8,6]]},"published-print":{"date-parts":[[2026,8,1]]}},"URL":"https:\/\/doi.org\/10.1093\/milmed\/usag036","relation":{},"ISSN":["0026-4075","1930-613X"],"issn-type":[{"value":"0026-4075","type":"print"},{"value":"1930-613X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,7]]},"published":{"date-parts":[[2026,7]]}}}