{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T11:28:03Z","timestamp":1783164483430,"version":"3.54.6"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2001,11,1]]},"DOI":"10.1093\/ndt\/16.11.2194","type":"journal-article","created":{"date-parts":[[2002,7,26]],"date-time":"2002-07-26T22:42:52Z","timestamp":1027723372000},"page":"2194-2200","source":"Crossref","is-referenced-by-count":122,"title":["A prospective study of complications associated with cuffed, tunnelled haemodialysis catheters\u2020"],"prefix":"10.1093","volume":"16","author":[{"given":"Mark A.","family":"Little","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aisling","family":"O'Riordan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Lucey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Farrell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J.","family":"Conlon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Joseph","family":"Walshe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2001,11]]},"reference":[{"key":"key\n\t\t\t\t20180110092259_R1","doi-asserted-by":"crossref","unstructured":"Schwab SJ, Buller GL, McCann RJ, Bollinger RR, Stickel DL. Prospective evaluation of a Dacron cuffed hemodialysis HC for prolonged use. Am J Kidney Dis1988; 11: 166\u2013169","DOI":"10.1016\/S0272-6386(88)80206-3"},{"key":"key\n\t\t\t\t20180110092259_R2","doi-asserted-by":"crossref","unstructured":"Kumwenda MJ, Wright FK, Haybittle KJ. Survey of permanent central venous HCs for haemodialysis in the UK. Nephrol Dial Transplant1996; 11: 830\u2013832","DOI":"10.1093\/oxfordjournals.ndt.a027407"},{"key":"key\n\t\t\t\t20180110092259_R3","doi-asserted-by":"crossref","unstructured":"Jean G, Chazot C, Vanel T et al. Central venous catheters for haemodialysis: looking for optimal blood flow. Nephrol Dial Transplant1997; 12: 1689\u20131691","DOI":"10.1093\/ndt\/12.8.1689"},{"key":"key\n\t\t\t\t20180110092259_R4","doi-asserted-by":"crossref","unstructured":"Moss AH, Vasilakis C, Holley JL, Foulks CJ, Pillai K, McDowell DE. Use of a silicone dual\u2010lumen HC with a Dacron cuff as a long\u2010term vascular access for hemodialysis patients. Am J Kidney Dis1990; 16: 211\u2013215","DOI":"10.1016\/S0272-6386(12)81020-1"},{"key":"key\n\t\t\t\t20180110092259_R5","doi-asserted-by":"crossref","unstructured":"Twardowski ZJ, Van Stone JC, Jones ME, Klusmeyer ME, Haynie JD. Blood recirculation in intravenous catheters for hemodialysis. J Am Soc Nephrol1993; 3: 1978\u20131981","DOI":"10.1681\/ASN.V3121978"},{"key":"key\n\t\t\t\t20180110092259_R6","doi-asserted-by":"crossref","unstructured":"Marr KA, Sexton DJ, Conlon PJ, Corey GR, Schwab SJ, Kirkland KB. HC\u2010related bacteremia and outcome of attempted HC salvage in patients undergoing hemodialysis. Ann Intern Med1997; 127: 275\u2013280","DOI":"10.7326\/0003-4819-127-4-199708150-00003"},{"key":"key\n\t\t\t\t20180110092259_R7","doi-asserted-by":"crossref","unstructured":"Pearson ML. Guideline for the prevention of intravascular device\u2010related infections. Part I. Intravascular device\u2010related infections: an overview. Am J Infect Control1996; 24: 262\u2013293","DOI":"10.1016\/S0196-6553(96)90058-9"},{"key":"key\n\t\t\t\t20180110092259_R8","doi-asserted-by":"crossref","unstructured":"Cunney R, Magee C, McNamara E, Smyth EG, Walshe J. Clostridium difficile colitis associated with chronic renal failure. Nephrol Dial Transplant1998; 13: 2842\u20132846","DOI":"10.1093\/ndt\/13.11.2842"},{"key":"key\n\t\t\t\t20180110092259_R9","doi-asserted-by":"crossref","unstructured":"Siegman\u2010Igra Y, Anglim AM, Shapiro DE, Adal KA, Strain BA, Farr BM. Diagnosis of catheter\u2010related bloodstream infection: a meta\u2010analysis. J Clin Microbiol1997; 35: 928\u2013936","DOI":"10.1128\/JCM.35.4.928-936.1997"},{"key":"key\n\t\t\t\t20180110092259_R10","doi-asserted-by":"crossref","unstructured":"Canaud B, Leray\u2010Moragues H, Garrigues V, Mion C. Permanent twin catheter: a vascular access option of choice for hemodialysis in elderly patients. Nephrol Dial Transplant1998; 13 [Suppl 7]: 82\u201388","DOI":"10.1093\/ndt\/13.suppl_7.82"},{"key":"key\n\t\t\t\t20180110092259_R11","doi-asserted-by":"crossref","unstructured":"Almirral J, Gonzalez J, Rello J et al. Infection of hemodialysis catheters: incidence and mechanisms. Am J Nephrol1989; 9: 454\u2013459","DOI":"10.1159\/000168012"},{"key":"key\n\t\t\t\t20180110092259_R12","unstructured":"Mosquera DA, Gibson SP, Goldman MD. Vascular access surgery: a 2\u2010year study and comparison with the Permcath. Nephrol Dial Transplant1992; 7: 1111\u20131115"},{"key":"key\n\t\t\t\t20180110092259_R13","doi-asserted-by":"crossref","unstructured":"Prabhu PN, Kerns SR, Sabatelli FW, Hawkins IF, Ross EA. Long\u2010term performance and complications of the Tesio twin catheter system for hemodialysis access. Am J Kidney Dis1997; 30: 213\u2013218","DOI":"10.1016\/S0272-6386(97)90054-8"},{"key":"key\n\t\t\t\t20180110092259_R14","doi-asserted-by":"crossref","unstructured":"Saad TF. Bacteremia associated with tunnelled, cuffed hemodialysis catheters. Am J Kidney Dis1999; 34: 1114\u20131124","DOI":"10.1016\/S0272-6386(99)70018-1"},{"key":"key\n\t\t\t\t20180110092259_R15","doi-asserted-by":"crossref","unstructured":"Beathard GA. Management of bacteremia associated with tunneled\u2010cuffed hemodialysis catheters. J Am Soc Nephrol1999; 10: 1045\u20131049","DOI":"10.1681\/ASN.V1051045"},{"key":"key\n\t\t\t\t20180110092259_R16","doi-asserted-by":"crossref","unstructured":"Palder SB, Kirkman RL, Whittemore AD, Hakim RM, Lazarus JM, Tilney NL. Vascular access for hemodialysis. Patency rates and results of revision. Ann Surg1985; 202: 235\u2013239","DOI":"10.1097\/00000658-198508000-00015"},{"key":"key\n\t\t\t\t20180110092259_R17","doi-asserted-by":"crossref","unstructured":"NKF\u2010DOQI clinical practice guidelines for vascular access. Am J Kidney Dis1997; 30 [Suppl 3]: 8173","DOI":"10.1016\/S0272-6386(97)70028-3"}],"container-title":["Nephrology Dialysis Transplantation"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ndt\/article-pdf\/16\/11\/2194\/23368888\/162194.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T17:00:23Z","timestamp":1621270823000},"score":1,"resource":{"primary":{"URL":"http:\/\/academic.oup.com\/ndt\/article\/16\/11\/2194\/1933049"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,11,1]]},"references-count":17,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2001,11]]},"published-print":{"date-parts":[[2001,11,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ndt\/16.11.2194","relation":{},"ISSN":["1460-2385","0931-0509"],"issn-type":[{"value":"1460-2385","type":"electronic"},{"value":"0931-0509","type":"print"}],"subject":[],"published-other":{"date-parts":[[2001,11]]},"published":{"date-parts":[[2001,11,1]]}}}