{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T23:04:20Z","timestamp":1769382260030,"version":"3.49.0"},"reference-count":11,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T00:00:00Z","timestamp":1769299200000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,24]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Abnormal central venous anatomy can obstruct cardiac-device implantation. We report a 54-year-old patient found to be in complete heart-block after identification of profound bradycardia, requiring cardiac-pacing. Echocardiography revealed systolic dysfunction, prompting a plan for cardiac resynchronization therapy. Conventional lead placement was impossible due to failed guide-wire advancement bilaterally. Peri-procedural venography demonstrated attenuation of both brachiocephalic veins and contrast-enhanced computed tomography confirmed complete central venous occlusion (CVO). Further history identified previous chemotherapy delivered via central venous catheters, as the likely aetiology for the CVO and systolic dysfunction. Alternative pacing options were considered. Ultimately the leadless Micra-AV-pacemaker was successfully implanted via the femoral vein with good clinical recovery. This unique case highlights CVO as an obstacle to cardiac-device implantation, with specific patients at increased risk. Pre-procedural imaging in those at-risk may reduce procedure failure and facilitate appropriate device strategy choice. Leadless pacing provides a safe, effective alternative in cases of CVO.<\/jats:p>","DOI":"10.1093\/omcr\/omaf292","type":"journal-article","created":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T13:08:17Z","timestamp":1765458497000},"source":"Crossref","is-referenced-by-count":0,"title":["Asymptomatic central venous occlusion secondary to central venous catheter-use complicating pacemaker implantation: a leadless solution"],"prefix":"10.1093","volume":"2026","author":[{"given":"James","family":"Baudry","sequence":"first","affiliation":[{"name":"Cardiology, East Lancashire Hospital NHS Trust (Royal Blackburn Hospital, Haslingden Road, Blackburn BB2 3HH ,","place":["United Kingdom)"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6730-4039","authenticated-orcid":false,"given":"Christopher","family":"Cassidy","sequence":"additional","affiliation":[{"name":"Cardiology, Blackpool NHS Teaching Hospitals (Blackpool Victoria Hospital, Whinney Heys Road, Blackpool FY3 8NR ,","place":["United Kingdom)"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kanarath","family":"Balachandran","sequence":"additional","affiliation":[{"name":"Cardiology, East Lancashire Hospital NHS Trust (Royal Blackburn Hospital, Haslingden Road, Blackburn BB2 3HH ,","place":["United Kingdom)"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,1,25]]},"reference":[{"key":"2026012509585404700_ref1","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur Heart J"},{"key":"2026012509585404700_ref2","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1093\/bja\/aes497","article-title":"Misplaced central venous catheters: applied anatomy and practical management","volume":"110","author":"Gibson","year":"2013","journal-title":"Br J Anaesth"},{"key":"2026012509585404700_ref3","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1182\/asheducation-2014.1.306","article-title":"Central venous catheter\u2013related thrombosis","volume":"2014","author":"Geerts","year":"2014","journal-title":"Hematology Am Soc Hematol Educ Program"},{"key":"2026012509585404700_ref4","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s10840-005-1140-1","article-title":"Venous thrombosis and stenosis after implantation of pacemakers and defibrillators","volume":"13","author":"Rozmus","year":"2005","journal-title":"J Interv Card Electrophysiol"},{"key":"2026012509585404700_ref5","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1046\/j.1460-9592.2002.01605.x","article-title":"The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads","volume":"25","author":"Oginosawa","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026012509585404700_ref6","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1053\/eupc.2000.0135","article-title":"Permanent pacemaker implantation via the femoral vein: an alternative in cases with contraindications to the pectoral approach","volume":"3","author":"Mathur","year":"2001","journal-title":"Europace."},{"key":"2026012509585404700_ref7","doi-asserted-by":"publisher","first-page":"e005443","DOI":"10.1161\/CIRCEP.117.005443","article-title":"Cancer treatment\u2013induced arrhythmias: focus on chemotherapy and targeted therapies","volume":"10","author":"Buza","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026012509585404700_ref8","doi-asserted-by":"publisher","first-page":"2244","DOI":"10.1253\/circj.CJ-21-0366","article-title":"Utility of leadless pacemaker implantation in unusual clinical scenarios","volume":"85","author":"Ono","year":"2021","journal-title":"Circ J"},{"key":"2026012509585404700_ref9","doi-asserted-by":"publisher","first-page":"1538","DOI":"10.1016\/j.jvs.2009.12.022","article-title":"A comprehensive review of Paget\u2013Schroetter syndrome","volume":"51","author":"Illig","year":"2010","journal-title":"J Vasc Surg"},{"key":"2026012509585404700_ref10","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euae257","article-title":"Improved outcomes with leadless vs. single-chamber transvenous pacemaker in haemodialysis patients","volume":"26","author":"Panico","year":"2024","journal-title":"Europace."},{"key":"2026012509585404700_ref11","doi-asserted-by":"publisher","first-page":"1979","DOI":"10.1093\/eurheartj\/ehaf119","article-title":"Leadless pacing: a comprehensive review","volume":"46","author":"Saleem-Talib","year":"2025","journal-title":"Eur Heart J"}],"container-title":["Oxford Medical Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/omcr\/article-pdf\/2026\/1\/omaf292\/66569179\/omaf292.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/omcr\/article-pdf\/2026\/1\/omaf292\/66569179\/omaf292.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T14:58:59Z","timestamp":1769353139000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/omcr\/article\/doi\/10.1093\/omcr\/omaf292\/8440717"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1,24]]}},"URL":"https:\/\/doi.org\/10.1093\/omcr\/omaf292","relation":{},"ISSN":["2053-8855"],"issn-type":[{"value":"2053-8855","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,1]]},"published":{"date-parts":[[2026,1]]},"article-number":"omaf292"}}