{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:46:20Z","timestamp":1786124780364,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2017,10,10]],"date-time":"2017-10-10T00:00:00Z","timestamp":1507593600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/ mailto:journals.permissions@oup.com"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Operative Surg.","ONSURG"],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND<\/jats:title>\n                    <jats:p>The use of intraoperative navigation during microscope cases can be limited when attention needs to be divided between the operative field and the navigation screens. Heads-up display (HUD), also referred to as augmented reality, permits visualization of navigation information during surgery workflow.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>To detail our initial experience with HUD.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>We retrospectively reviewed patients who underwent HUD-assisted surgery from April 2016 through April 2017. All lesions were assessed for accuracy and those from the latter half of the study were assessed for utility.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>\n                      Seventy-nine patients with 84 pathologies were included. Pathologies included aneurysms (14), arteriovenous malformations (6), cavernous malformations (5), intracranial stenosis (3), meningiomas (27), metastasis (4), craniopharygniomas (4), gliomas (4), schwannomas (3), epidermoid\/dermoids (3), pituitary adenomas (2) hemangioblastoma (2), choroid plexus papilloma (1), lymphoma (1), osteoblastoma (1), clival chordoma (1), cerebrospinal fluid leak (1), abscess (1), and a cerebellopontine angle Teflon granuloma (1). Fifty-nine lesions were deep and 25 were superficial. Structures identified included the lesion (81), vessels (48), and nerves\/brain tissue (31). Accuracy was deemed excellent (71.4%), good (20.2%), or poor (8.3%). Deep lesions were less likely to have excellent accuracy (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .029). HUD was used during bed\/head positioning (50.0%), skin incision (17.3%), craniotomy (23.1%), dural opening (26.9%), corticectomy (13.5%), arachnoid opening (36.5%), and intracranial drilling (13.5%). HUD was deactivated at some point during the surgery in 59.6% of cases. There were no complications related to HUD use.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>HUD can be safely used for a wide variety of vascular and oncologic intracranial pathologies and can be utilized during multiple stages of surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ons\/opx205","type":"journal-article","created":{"date-parts":[[2017,10,10]],"date-time":"2017-10-10T05:57:04Z","timestamp":1507615024000},"page":"184-193","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":66,"title":["Navigation-Linked Heads-Up Display in Intracranial Surgery: Early Experience"],"prefix":"10.1227","volume":"15","author":[{"given":"Justin R","family":"Mascitelli","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leslie","family":"Schlachter","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander G","family":"Chartrain","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Holly","family":"Oemke","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Gilligan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony B","family":"Costa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj K","family":"Shrivastava","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua B","family":"Bederson","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2018,8]]},"reference":[{"key":"bib1-20240909","article-title":"Technical feasibility and safety of an intraoperative head-up display device during spine instrumentation","author":"Yoon","year":"2016","journal-title":"Int J Med Robot"},{"issue":"8","key":"bib2-20240909","doi-asserted-by":"crossref","first-page":"e105224","DOI":"10.1371\/journal.pone.0105224","article-title":"Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-Up display surgeon feedback","volume":"9","author":"Ehlers","year":"2014","journal-title":"PLoS One"},{"issue":"1","key":"bib3-20240909","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/IAE.0000000000000689","article-title":"Heads-Up surgery for vitreoretinal procedures","volume":"36","author":"Eckardt","year":"2016","journal-title":"Retina"},{"issue":"5","key":"bib4-20240909","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1177\/1932296814535561","article-title":"A heads-up display for diabetic limb salvage surgery","volume":"8","author":"Armstrong","year":"2014","journal-title":"J Diabetes Sci Technol"},{"issue":"2","key":"bib5-20240909","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1097\/PRS.0000000000001453","article-title":"Google glass as an alternative to standard fluoroscopic visualization for percutaneous fixation of hand fractures","volume":"136","author":"Chimenti","year":"2015","journal-title":"Plast Reconstr Surg"},{"issue":"6","key":"bib6-20240909","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.jemermed.2014.07.045","article-title":"Ultrasound-guided central venous access using google glass","volume":"47","author":"Wu","year":"2014","journal-title":"J Emerg Med"},{"issue":"4","key":"bib7-20240909","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1213\/ANE.0b013e3181d3e647","article-title":"Monitoring with head-mounted displays in general anesthesia","volume":"110","author":"Liu","year":"2010","journal-title":"Anesth Analg"},{"issue":"suppl 2","key":"bib8-20240909","first-page":"214","article-title":"Robotic autopositioning of the operating microscope","volume":"10","author":"Oppenlander","year":"2014","journal-title":"Neurosurgery"},{"issue":"2","key":"bib9-20240909","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/S0901-5027(96)80062-2","article-title":"Image-guided surgery","volume":"25","author":"Wagner","year":"1996","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"1-4 pt 1","key":"bib10-20240909","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1159\/000099897","article-title":"Volumegraph (overlaid three-dimensional image-guided navigation). Clinical application of augmented reality in neurosurgery","volume":"68","author":"Iseki","year":"1997","journal-title":"Stereotact Funct Neurosurg"},{"issue":"2-4","key":"bib11-20240909","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1159\/000029708","article-title":"A system for microscope-assisted guided interventions","volume":"72","author":"King","year":"1999","journal-title":"Stereotact Funct Neurosurg"},{"issue":"6","key":"bib12-20240909","first-page":"1393","article-title":"Endoscopic augmented reality navigation system for endonasal transsphenoidal surgery to treat pituitary tumors: technical note","volume":"50","author":"Kawamata","year":"2002","journal-title":"Neurosurgery"},{"issue":"4","key":"bib13-20240909","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1227\/01.NEU.0000349918.36700.1C","article-title":"DEX-RAY","volume":"65","author":"Kockro","year":"2009","journal-title":"Neurosurgery"},{"issue":"1","key":"bib14-20240909","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1159\/000354816","article-title":"Easy-to-use augmented reality neuronavigation using a wireless tablet PC","volume":"92","author":"Deng","year":"2014","journal-title":"Stereotact Funct Neurosurg"},{"issue":"suppl 2","key":"bib15-20240909","first-page":"252","article-title":"Augmented reality in the surgery of cerebral aneurysms","volume":"10","author":"Cabrilo","year":"2014","journal-title":"Neurosurgery"},{"issue":"9","key":"bib16-20240909","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.1007\/s00701-014-2183-9","article-title":"Augmented reality in the surgery of cerebral arteriovenous malformations: technique assessment and considerations","volume":"156","author":"Cabrilo","year":"2014","journal-title":"Acta Neurochir"},{"issue":"4","key":"bib17-20240909","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1016\/j.wneu.2014.12.020","article-title":"Augmented reality-assisted bypass surgery: embracing minimal invasiveness","volume":"83","author":"Cabrilo","year":"2015","journal-title":"World Neurosurg"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/15\/2\/184\/30206364\/opx205.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.ovid.com\/01787389-201808000-00008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:45:36Z","timestamp":1786121136000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01787389-201808000-00008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,10]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1093\/ons\/opx205","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,10]]},"assertion":[{"value":"2017-02-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-09-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}