{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:46:41Z","timestamp":1786124801710,"version":"build-2736575974"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2019,12,9]],"date-time":"2019-12-09T00:00:00Z","timestamp":1575849600000},"content-version":"vor","delay-in-days":767,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Operative Surg.","ONSURG"],"published-print":{"date-parts":[[2018,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND AND IMPORTANCE<\/jats:title>\n                    <jats:p>Coil migration is a potential complication of endovascular aneurysm treatment. Dislodged coils into the parent artery require retrieval to prevent thromboembolic complications. A variety of techniques for coil retrieval have been described, including the use of single stentrievers and aspiration catheters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CLINICAL PRESENTATION<\/jats:title>\n                    <jats:p>The use of 2 stentrievers, as opposed to a single device, was thought to be advantageous in coil removal by the additional point of friction due to the extensive length of coil stretching and earlier failure of a single device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>In this report, 2 synchronous Solitaire FR Revascularization Devices (Covidien\/Medtronic, Dublin, Ireland) were deployed, 1 distal and 1 proximal, to retrieve an inadvertently deployed coil.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ons\/opx230","type":"journal-article","created":{"date-parts":[[2017,11,2]],"date-time":"2017-11-02T12:06:18Z","timestamp":1509624378000},"page":"E19-E22","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Endovascular Coil Retrieval Using Dual Synchronous Solitaire Revascularization Devices"],"prefix":"10.1227","volume":"15","author":[{"given":"John D","family":"Nerva","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, University of Washington, Seattle, Washington"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan P","family":"Morton","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, University of Washington, Seattle, Washington"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cory M","family":"Kelly","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, University of Washington, Seattle, Washington"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danial K","family":"Hallam","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Washington, Seattle, Washington"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael R","family":"Levitt","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, University of Washington, Seattle, Washington"},{"name":"Department of Radiology, University of Washington, Seattle, Washington"},{"name":"Department of Mechanical Engineering, University of Washington, Seattle, Washington"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2018,9]]},"reference":[{"issue":"6","key":"bib1-20240909","first-page":"173","article-title":"Management strategies for intraprocedural coil migration during endovascular treatment of intracranial aneurysms","volume":"6","author":"Ding","year":"2014","journal-title":"J Neurosurg"},{"issue":"5","key":"bib2-20240909","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1007\/s002340050757","article-title":"Post-procedure migration of guglielmi detachable coils and mechanical detachable spirals","volume":"41","author":"Phatouros","year":"1999","journal-title":"Neuroradiology"},{"issue":"5","key":"bib3-20240909","doi-asserted-by":"crossref","first-page":"e19","DOI":"10.1136\/neurintsurg-2014-011181.rep","article-title":"Endovascular coil retrieval using a TrevoProVue stentriever","volume":"7","author":"Kabbani","year":"2015","journal-title":"J Neurointerv Surg"},{"issue":"3","key":"bib4-20240909","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.jocn.2013.10.012","article-title":"Intraprocedural retrieval of migrated coils during endovascular aneurysm treatment with the Trevo Stentriever device","volume":"21","author":"Liu","year":"2014","journal-title":"J Clin Neurosci"},{"issue":"11","key":"bib5-20240909","doi-asserted-by":"crossref","first-page":"e44","DOI":"10.1136\/neurintsurg-2015-012039.rep","article-title":"A direct aspiration first pass technique for retrieval of a detached coil","volume":"8","author":"Masahira","year":"2015","journal-title":"J Neurointerv Surg"},{"issue":"4","key":"bib6-20240909","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s00234-006-0051-x","article-title":"Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms","volume":"48","author":"Dinc","year":"2006","journal-title":"Neuroradiology"},{"issue":"2","key":"bib7-20240909","first-page":"327","article-title":"A new device for endovascular coil retrieval from intracranial vessels: alligator retrieval device","volume":"27","author":"Henkes","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"issue":"6","key":"bib8-20240909","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.jocn.2012.06.012","article-title":"Solitaire\u00ae stent for endovascular coil retrieval","volume":"20","author":"Hopf-Jensen","year":"2013","journal-title":"J Clin Neurosci"},{"issue":"1","key":"bib9-20240909","doi-asserted-by":"crossref","first-page":"48","DOI":"10.7461\/jcen.2016.18.1.48","article-title":"Retrieval of distally migrated coils with detachable intracranial stent during coil embolization of cerebral aneurysm","volume":"18","author":"Singh","year":"2016","journal-title":"J Cerebrovasc Endovasc Neurosurg"},{"issue":"3","key":"bib10-20240909","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.diii.2015.09.004","article-title":"Retrieval of a dislocated coil and stent-assisted coiling by Solitaire(\u00ae) stent during endovascular treatment of an intracranial aneurysm","volume":"97","author":"Nas","year":"2016","journal-title":"Diagn Interv Imaging"},{"issue":"4","key":"bib11-20240909","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00062-010-0020-y","article-title":"Retrieval of displaced coil using a Solitaire(\u00ae) stent","volume":"20","author":"O\u2019Hare","year":"2010","journal-title":"Clin Neuroradiol"},{"issue":"1","key":"bib12-20240909","doi-asserted-by":"crossref","first-page":"173","DOI":"10.3171\/2015.5.JNS15145","article-title":"Rescue N-butyl-2 cyanoacrylate embolectomy using a Solitaire FR device after venous glue migration during arteriovenous malformation embolization: technical note","volume":"125","author":"Fahed","year":"2016","journal-title":"J Neurosurg"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/15\/3\/E19\/30210275\/opx230.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.ovid.com\/01787389-201809000-00021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:45:49Z","timestamp":1786121149000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01787389-201809000-00021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,2]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1093\/ons\/opx230","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,2]]},"assertion":[{"value":"2017-06-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-09-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}