{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T18:47:51Z","timestamp":1792176471215,"version":"4.4.0"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2018,8,3]],"date-time":"2018-08-03T00:00:00Z","timestamp":1533254400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/academic.oup.com\/journals\/pages\/about_us\/legal\/notices"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Operative Surg.","ONSURG"],"published-print":{"date-parts":[[2019,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND<\/jats:title>\n                    <jats:p>In cases of trigeminal neuralgia, the importance of durable separation of involved vessels from the trigeminal nerve as well as avoiding ongoing or recurrent compression by implanted material has been affirmed in recent literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>To demonstrate a novel and straightforward technique for trigeminal nerve decompression using a construct of Teflon felt patty (Bard Peripheral Vascular, Tempe, Arizona) secured with an aneurysm mini clip to achieve lasting results with no residual contact between implant or vessels and the nerve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Description of our technique and accompanying surgical video.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>As demonstrated in the video, this technique achieves an ideal, durable separation of the trigeminal nerve from the offending vasculature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>The authors present a description of a technique for decompression with the goal of leaving no contact between implanted material and the nerve. This is accomplished by securing the Teflon felt (Bard Peripheral Vascular) to the tentorium with an aneurysm clip.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ons\/opy212","type":"journal-article","created":{"date-parts":[[2018,8,3]],"date-time":"2018-08-03T10:00:08Z","timestamp":1533290408000},"page":"580-582","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Microvascular Decompression for Trigeminal Neuralgia: A Durable, Noncompressive Technique Using Teflon Secured With Mini Clip"],"prefix":"10.1227","volume":"16","author":[{"given":"Robert E","family":"Breeze","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, University of Colorado, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel B","family":"Craig","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Colorado, Aurora, Colorado"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,5]]},"reference":[{"issue":"2","key":"bib1-20240909","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/S0002-9610(34)90403-7","article-title":"Concerning the cause of trigeminal neuralgia","volume":"24","author":"Dandy","year":"1934","journal-title":"Am J Surg"},{"issue":"6","key":"bib2-20240909","first-page":"3589","article-title":"Treatment of trigeminal neuralgia by microvascular decompression","volume":"2","author":"Janetta","year":"1982","journal-title":"Neurol Surg"},{"issue":"6","key":"bib3-20240909","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1007\/s00701-012-1324-2","article-title":"Surgical technique for trigeminal microvascular decompression","volume":"154","author":"Broggi","year":"2012","journal-title":"Acta Neurochir"},{"issue":"3","key":"bib4-20240909","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s10143-011-0310-0","article-title":"Stitched sling retraction technique for microvascular decompression: procedures and techniques based on an anatomical viewpoint","volume":"34","author":"Masuoka","year":"2011","journal-title":"Neurosurg Rev"},{"issue":"7","key":"bib5-20240909","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1007\/s00701-007-1174-5","article-title":"Recurrent trigeminal neuralgia secondary to Teflon felt","volume":"149","author":"Vitali","year":"2007","journal-title":"Acta Neurochir (Wien)"},{"issue":"5","key":"bib6-20240909","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/s007010050469","article-title":"Recurrent trigeminal neuralgia after microvascular decompression using an interposing technique. Teflon felt adhesion and the sling retraction technique","volume":"142","author":"Matsushima","year":"2000","journal-title":"Acta Neurochir (Wien)"},{"issue":"4","key":"bib7-20240909","first-page":"341","article-title":"Microvascular decompression for trigeminal neuralgia: the importance of a non compressive technique - kaplan -meier analysis in a consecutive series of 330 patients","volume":"63","author":"Sindou","year":"2008","journal-title":"Neurosurgery"},{"issue":"2","key":"bib8-20240909","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/s10143-015-0607-5","article-title":"Outcome of microvascular decompression for trigeminal neuralgia treated with the stitched sling retraction technique","volume":"38","author":"Masuoka","year":"2015","journal-title":"Neurosurg Rev"},{"issue":"5","key":"bib9-20240909","doi-asserted-by":"crossref","first-page":"929","DOI":"10.3171\/jns.2007.106.5.929","article-title":"Use of fenestrated aneurysm clips in microvascular decompression surgery","volume":"106","author":"Attabib","year":"2007","journal-title":"J Neurosurg"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/16\/5\/580\/30214736\/opy212.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.ovid.com\/01787389-201905000-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:50:31Z","timestamp":1786121431000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01787389-201905000-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,3]]},"references-count":9,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1093\/ons\/opy212","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,3]]},"assertion":[{"value":"2018-01-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-07-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}