{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:45:42Z","timestamp":1786124742667,"version":"build-2736575974"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2019,2,6]],"date-time":"2019-02-06T00:00:00Z","timestamp":1549411200000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Operative Surg.","ONSURG"],"published-print":{"date-parts":[[2019,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND AND IMPORTANCE<\/jats:title>\n                    <jats:p>Dual iliac-screw and dual-rod fixation provides additional stability to lumbopelvic constructs and can be employed in management of neoplastic disease with extensive osseous involvement. Optimal iliac-screw positioning is vital to achieve the desired dual iliac-screw and dual-rod linkage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CLINICAL PRESENTATION<\/jats:title>\n                    <jats:p>In this report, we describe our technique with particular focus on subcrestal iliac-screw entry point position using a 4-quadrant teardrop radiological view concept in a case of minimally invasive L3-iliac spinopelvic fixation using dual iliac-screw and dual-rod for a patient with pathological sacral fracture. At the last follow-up 20 mo postsurgery there was minimal axial and radicular pain and no evidence of screw prominence. Radiographs showed no evidence of construct failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>The 4-quadrant teardrop concept provides a good visual reference for optimal subcrestal screw placement when employing a dual iliac-screw and dual-construct.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ons\/opy410","type":"journal-article","created":{"date-parts":[[2019,2,5]],"date-time":"2019-02-05T20:50:47Z","timestamp":1549399847000},"page":"E219-E223","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Minimally Invasive Dual Iliac-Screw and Dual-Rod Construct: A Case Report Describing Optimal Subcrestal Iliac-Screw Entry Points in the Surgical Treatment of Metastatic Lumbosacral Fracture"],"prefix":"10.1227","volume":"17","author":[{"given":"Gabriel","family":"Liu","sequence":"first","affiliation":[{"name":"University Orthopaedic, Hand and Reconstructive Surgery Cluster, National University Health System, National University Hospital, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammed Yaser","family":"Hasan","sequence":"additional","affiliation":[{"name":"University Orthopaedic, Hand and Reconstructive Surgery Cluster, National University Health System, National University Hospital, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,11]]},"reference":[{"issue":"15","key":"bib1-20240909","doi-asserted-by":"crossref","first-page":"E296","DOI":"10.1097\/01.BRS.0000083230.12704.E3","article-title":"Total sacrectomy and reconstruction for sacral tumors","volume":"28","author":"Doita","year":"2003","journal-title":"Spine"},{"issue":"6","key":"bib2-20240909","doi-asserted-by":"crossref","first-page":"E123","DOI":"10.1097\/01.BRS.0000115140.19829.4B","article-title":"Extended total sacrectomy and reconstruction for sacral tumor","volume":"29","author":"Ohata","year":"2004","journal-title":"Spine"},{"issue":"5","key":"bib3-20240909","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1097\/00007632-198307000-00006","article-title":"Spinal fusions to the sacrum in adults with scoliosis","volume":"8","author":"Kostuik","year":"1983","journal-title":"Spine"},{"issue":"8 Suppl","key":"bib4-20240909","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1097\/00007632-199208001-00004","article-title":"Biomechanical analysis of lumbosacral fixation","volume":"17","author":"McCord","year":"1992","journal-title":"Spine"},{"issue":"21","key":"bib5-20240909","doi-asserted-by":"crossref","first-page":"2312","DOI":"10.1097\/00007632-200211010-00003","article-title":"Biomechanical comparison of lumbosacral fixation techniques in a calf spine model","volume":"27","author":"Lebwohl","year":"2002","journal-title":"Spine"},{"issue":"6","key":"bib6-20240909","doi-asserted-by":"crossref","first-page":"E198","DOI":"10.1097\/BRS.0b013e3181c142bf","article-title":"Biomechanical comparison of iliac screws versus interbody femoral ring allograft on lumbosacral kinematics and sacral screw strain","volume":"35","author":"Cunningham","year":"2010","journal-title":"Spine"},{"issue":"3","key":"bib7-20240909","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/01.brs.0000197193.81296.f1","article-title":"Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity","volume":"31","author":"Tsuchiya","year":"2006","journal-title":"Spine"},{"issue":"4","key":"bib8-20240909","doi-asserted-by":"crossref","first-page":"347","DOI":"10.3340\/jkns.2010.48.4.347","article-title":"A mid-term follow-up result of spinopelvic fixation using iliac screws for lumbosacral fusion","volume":"48","author":"Hyun","year":"2010","journal-title":"J Korean Neurosurg S"},{"issue":"7","key":"bib9-20240909","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1097\/BSD.0b013e3181cc8e7f","article-title":"Long-term results of iliac wing fixation below extensive fusions in ambulatory adult patients with spinal disorders","volume":"23","author":"Kasten","year":"2010","journal-title":"J Spinal Disord Tech"},{"issue":"1","key":"bib10-20240909","doi-asserted-by":"crossref","first-page":"99","DOI":"10.3171\/SPI-07\/07\/099","article-title":"Palliative dual iliac screw fixation for lumbosacral metastasis","volume":"7","author":"Fujibayashi","year":"2007","journal-title":"J Neurosurg Spine"},{"issue":"7","key":"bib11-20240909","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1097\/BSD.0b013e31815b5cc4","article-title":"Ilio-lumbar fixation\u2013the Amrita technique","volume":"21","author":"Acharya","year":"2008","journal-title":"J Spinal Disord Tech"},{"issue":"2","key":"bib12-20240909","doi-asserted-by":"crossref","first-page":"E17","DOI":"10.3171\/FOC\/2008\/25\/8\/E17","article-title":"Percutaneous iliac screw placement: description of a new minimally invasive technique","volume":"25","author":"Wang","year":"2008","journal-title":"Neurosurg Focus"},{"issue":"12","key":"bib13-20240909","doi-asserted-by":"crossref","first-page":"4043","DOI":"10.1007\/s00586-016-4387-6","article-title":"Minimally invasive iliac screw fixation in treating painful metastatic lumbosacral deformity: a technique description and clinical results","volume":"25","author":"Liu","year":"2016","journal-title":"Eur Spine J"},{"issue":"3","key":"bib14-20240909","doi-asserted-by":"crossref","first-page":"316","DOI":"10.3171\/2017.3.SPINE161293","article-title":"Minimally invasive dual iliac screw, dual rod fixation in a rare case of pathological sacral fracture from a paraganglionoma: a technique description","volume":"27","author":"Hasan","year":"2017","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"bib15-20240909","doi-asserted-by":"crossref","first-page":"E68","DOI":"10.1097\/BRS.0000000000002239","article-title":"Subcrestal iliac-screw. A technical note describing a free hand, in-line, low profile iliac screw insertion technique to avoid side-connector use and reduce implant complications","volume":"43","author":"Liu","year":"2018","journal-title":"Spine"},{"issue":"16","key":"bib16-20240909","doi-asserted-by":"crossref","first-page":"E565","DOI":"10.1097\/BRS.0b013e3181ac8fc4","article-title":"Effect of iliac screw insertion depth on the stability and strength of lumbo-iliac fixation constructs: an anatomical and biomechanical study","volume":"34","author":"Zheng","year":"2009","journal-title":"Spine"},{"issue":"2","key":"bib17-20240909","doi-asserted-by":"crossref","first-page":"E5","DOI":"10.3171\/foc.2003.15.2.5","article-title":"Surgical techniques for total sacrectomy and spinopelvic reconstruction","volume":"15","author":"Zhang","year":"2003","journal-title":"Neurosurg Focus"},{"issue":"7","key":"bib18-20240909","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1007\/s00586-010-1343-8","article-title":"Biomechanical advantages of dual over single iliac screws in lumbo-iliac fixation construct","volume":"19","author":"Yu","year":"2010","journal-title":"Eur Spine J"},{"issue":"7","key":"bib19-20240909","doi-asserted-by":"crossref","first-page":"E388","DOI":"10.1097\/BRS.0000000000001282","article-title":"Use of supplemental short pre-contoured accessory rods and cobalt chrome alloy posterior rods reduces primary rod strain and range of motion across the pedicle subtraction osteotomy level","volume":"41","author":"Hallager","year":"2016","journal-title":"Spine"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/17\/5\/E219\/30092205\/opy410.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.ovid.com\/10.1093\/ons\/opy410","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:45:04Z","timestamp":1786121104000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1093\/ons\/opy410"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,5]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1093\/ons\/opy410","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,5]]},"assertion":[{"value":"2018-09-01","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}}]}}