{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:03:00Z","timestamp":1787068980445,"version":"build-2736575974"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T00:00:00Z","timestamp":1553040000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Operative Surg.","ONSURG"],"published-print":{"date-parts":[[2019,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND<\/jats:title>\n                    <jats:p>Embolization of intracranial aneurysms with the pipeline embolization device (PED; Medtronic, Dublin, Ireland) is a widely used technique. Despite adequate dual antiplatelet therapy and intraprocedural anticoagulation, in-stent thrombosis has been described. There is limited evidence for best management of this complication.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>To describe in detail the technique used to perform thrombectomy of a recently placed PED with in-stent thrombosis. The aim of the procedure is to leave the PED in place and only perform thrombectomy of the luminal clot.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>We describe two cases of successful thrombectomy with a stentriever of acutely occluded PEDs. A total of 2 patients underwent PED embolization of 2 previously clipped aneurysms. Despite optimal deployment of the PEDs and excellent angiographic results, both patients developed symptoms of right hemispheric stroke within 1 h of the procedure. A thrombectomy was performed in each patient with the stentriever within the newly deployed PED. Thrombectomy was successful and there was no evidence of PED displacement of vascular injury.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>Stentriever thrombectomy of intraluminal clot can be performed effectively when the entire stentriever device is deployed within the PED. We did not experience any PED displacement, vessel damage, spasm, or device malfunction using this technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>We report the use of a stentriever to perform thrombectomy for in-stent thrombosis after PED placement as an additional treatment option of acute occlusion. This technique has not been previously described.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ons\/opz023","type":"journal-article","created":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T06:31:00Z","timestamp":1553063460000},"page":"491-496","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Mechanical Thrombectomy of Acutely Occluded Flow Diverters"],"prefix":"10.1227","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2764-2268","authenticated-orcid":false,"given":"Edgar A","family":"Samaniego","sequence":"first","affiliation":[{"name":"Department of Neurology, Neurosurgery and Radiology, University of Iowa Hospitals and Clinics, Iowa City, Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudeepta","family":"Dandapat","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Iowa Hospitals and Clinics, Iowa City, Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge A","family":"Roa","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Iowa Hospitals and Clinics, Iowa City, Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Zanaty","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daichi","family":"Nakagawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David M","family":"Hasan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,11]]},"reference":[{"key":"bib1-20240909","doi-asserted-by":"crossref","first-page":"e164","DOI":"10.1016\/j.wneu.2017.09.125","article-title":"Endovascular treatment of ruptured vertebrobasilar dissecting aneurysms using flow diversion embolization devices: single-institution experience","volume":"109","author":"Guerrero","year":"2018","journal-title":"World Neurosurg"},{"issue":"3","key":"bib2-20240909","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1148\/radiol.13120099","article-title":"Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial","volume":"267","author":"Becske","year":"2013","journal-title":"Radiology"},{"issue":"1","key":"bib3-20240909","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1093\/neuros\/nyw014","article-title":"Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the pipeline for uncoilable or failed aneurysms trial","volume":"80","author":"Becske","year":"2017","journal-title":"Neurosurgery"},{"issue":"4","key":"bib4-20240909","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1161\/STROKEAHA.116.016521","article-title":"Ischemic stroke after treatment of intraprocedural thrombosis during stent-assisted coiling and flow diversion","volume":"48","author":"Adeeb","year":"2017","journal-title":"Stroke"},{"issue":"6","key":"bib5-20240909","doi-asserted-by":"crossref","first-page":"E17","DOI":"10.3171\/2017.3.FOCUS16450","article-title":"Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis","volume":"42","author":"Zhou","year":"2017","journal-title":"Neurosurgical Focus"},{"key":"bib6-20240909","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.wneu.2016.08.050","article-title":"Same-day discharge after treatment with the pipeline embolization device using monitored anesthesia care","volume":"96","author":"Zanaty","year":"2016","journal-title":"World Neurosurg"},{"issue":"3","key":"bib7-20240909","first-page":"onsE313","article-title":"Very late thrombosis of a pipeline embolization device construct: case report","volume":"67","author":"Fiorella","year":"2010","journal-title":"Neurosurgery"},{"issue":"5","key":"bib8-20240909","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1136\/neurintsurg-2016-012547.rep","article-title":"Solitaire stentectomy: \u2018Deploy and Engage\u2019 and \u2018Loop and Snare\u2019 techniques","volume":"10","author":"Parthasarathy","year":"2018","journal-title":"J NeuroIntervent Surg"},{"issue":"2","key":"bib1a-20240909","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1136\/neurintsurg-2016-012587","article-title":"Intra-arterial versus intravenous abciximab therapy for thromboembolic complications of neuroendovascular procedures: case review and meta-analysis","volume":"9","author":"Kansagra","year":"2017","journal-title":"J Neurointervent Surg"},{"issue":"1","key":"bib2a-20240909","doi-asserted-by":"crossref","first-page":"108","DOI":"10.3174\/ajnr.A4111","article-title":"International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study","volume":"36","author":"Kallmes","year":"2015","journal-title":"Am J Neuroradiol"},{"issue":"5","key":"bib2b-20240909","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1001\/jama.2017.9644","article-title":"Effect of endovascular contact aspiration vs stent retriever on revascularization in patients with acute ischemic stroke and large vessel occlusion","volume":"318","author":"Lapergue","year":"2017","journal-title":"JAMA"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/17\/5\/491\/33422498\/opz023.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.ovid.com\/10.1093\/ons\/opz023","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:43:24Z","timestamp":1786121004000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1093\/ons\/opz023"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,20]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1093\/ons\/opz023","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,20]]},"assertion":[{"value":"2018-07-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-02-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}