{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T17:55:42Z","timestamp":1786125342748,"version":"build-2736575974"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T00:00:00Z","timestamp":1570147200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Operative Surg.","ONSURG"],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND<\/jats:title>\n                    <jats:p>With the recent advances in endovascular treatment devices, it has become standard in wide-neck or large intracranial aneurysms to perform coil embolization with adjunctive techniques. However, device-related perioperative complications have been reported because of the use of more complex systems.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>To investigate patients who developed multiple parenchymal lesions after undergoing coil embolization for treating an unruptured intracranial aneurysm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>This study investigated 305 consecutive patients who underwent coil embolization of unruptured intracranial aneurysms between 2015 and 2017. Delayed inflammatory changes referred to the delayed observation of multiple cerebral white matter lesions on follow-up magnetic resonance imaging at an area corresponding to the perfused area of the treatment target vessel. The timing and pattern of onset, device used, the combined use of adjunctive techniques, and the clinical course after steroid treatment were retrospectively investigated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>The 7 patients (2.3%) who showed delayed inflammatory changes were all women with a mean age of 59 yr. A mean duration from treatment to onset was 28 d. Symptoms were convulsions in 3 patients, hemiplegia in 2 patients, and homonymous hemianopia in 1 patient. All 7 patients were treated with adjunctive technique including stents, double catheter method, and balloon assist. Response to steroid treatment was satisfactory both clinically and on imaging in all 7 patients. Skin patch test was positive for nickel allergy in 2 patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>Clinicians must be fully aware of symptomatic delayed inflammatory changes may occur after endovascular aneurysmal treatment with the use of various devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ons\/opz299","type":"journal-article","created":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T04:56:53Z","timestamp":1570165013000},"page":"76-83","source":"Crossref","is-referenced-by-count":26,"title":["Delayed Intracranial Parenchymal Changes After Aneurysmal Coil Embolization Procedures for Unruptured Intracranial Aneurysms"],"prefix":"10.1227","volume":"19","author":[{"given":"Ichiro","family":"Nakagawa","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hun Soo","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Kotsugi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yudai","family":"Morisaki","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Wada","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuta","family":"Aketa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Osaka Police Hospital, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsutoshi","family":"Takayama","sequence":"additional","affiliation":[{"name":"Department of Radiology and Interventional Neuroradiology, Ishinkai Yao General Hospital, Yao, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenta","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Osaka General Medical Center, Osaka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Deguchi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nara City Hospital, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimihiko","family":"Kichikawa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Nakase","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nara Medical University, Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,7]]},"reference":[{"key":"bib1-20231101","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.wneu.2019.01.082","article-title":"Comparison of safety and effectiveness of endovascular treatments for unruptured intracranial large or giant aneurysms in internal carotid artery","volume":"125","author":"Yan","year":"2019","journal-title":"World Neurosurg"},{"issue":"10","key":"bib2-20231101","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.3174\/ajnr.A3976","article-title":"Enhancing brain lesions after endovascular treatment of aneurysms","volume":"35","author":"Cruz","year":"2014","journal-title":"AJNR Am J Neuroradiol."},{"issue":"1","key":"bib3-20231101","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/s12883-015-0303-7","article-title":"A patient develops transient unique cerebral and cerebellar lesions after unruptured aneurysm coiling","volume":"15","author":"Deguchi","year":"2015","journal-title":"BMC Neurol"},{"issue":"7","key":"bib4-20231101","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1038\/modpathol.2010.74","article-title":"Hydrophilic polymer emboli: an under-recognized iatrogenic cause of ischemia and infarct","volume":"23","author":"Mehta","year":"2010","journal-title":"Mod Pathol"},{"issue":"12","key":"bib5-20231101","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1016\/j.humpath.2009.04.027","article-title":"Intravascular polymer material after coil embolization of a giant cerebral aneurysm","volume":"40","author":"Mehta","year":"2009","journal-title":"Hum Pathol"},{"issue":"2","key":"bib6-20231101","first-page":"278","article-title":"Inadvertent foreign body embolization in diagnostic and therapeutic cerebral angiography","volume":"27","author":"Shannon","year":"2006","journal-title":"AJNR Am J Neuroradiol."},{"issue":"9","key":"bib7-20231101","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1007\/s00234-016-1699-5","article-title":"Non-ischemic cerebral enhancing lesions secondary to endovascular aneurysm therapy: nickel allergy or foreign body reaction? Case series and review of the literature","volume":"58","author":"Shotar","year":"2016","journal-title":"Neuroradiology"},{"issue":"1","key":"bib8-20231101","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1136\/neurintsurg-2017-013005.rep","article-title":"Nickel-associated delayed multiple white matter lesions after stent-assisted coil embolization of intracranial unruptured aneurysm","volume":"10","author":"Park","year":"2018","journal-title":"J NeuroIntervent Surg"},{"issue":"6","key":"bib9-20231101","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1016\/j.wneu.2010.03.026","article-title":"Abnormal white matter changes after cerebral aneurysm treatment with polyglycolic-polylactic acid coils","volume":"74","author":"Skolarus","year":"2010","journal-title":"World Neurosurg"},{"issue":"18","key":"bib10-20231101","doi-asserted-by":"crossref","first-page":"2133","DOI":"10.2169\/internalmedicine.53.2380","article-title":"Contrast-induced encephalopathy after coil embolization of an unruptured internal carotid artery aneurysm","volume":"53","author":"Nagamine","year":"2014","journal-title":"Intern Med"},{"issue":"10","key":"bib11-20231101","first-page":"1783","article-title":"Blood brain-barrier disruption of nonionic iodinated contrast medium following coil embolization of a ruptured intracerebral aneurysm","volume":"25","author":"Uchiyama","year":"2004","journal-title":"AJNR Am J Neuroradiol."},{"issue":"12","key":"bib12-20231101","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1136\/neurintsurg-2014-011457","article-title":"Clinical and angiographic outcomes after stent-assisted coiling of cerebral aneurysms with enterprise and neuroform stents: a comparative analysis of the literature","volume":"7","author":"King","year":"2015","journal-title":"J NeuroIntervent Surg"},{"issue":"10","key":"bib13-20231101","doi-asserted-by":"crossref","first-page":"2368","DOI":"10.1016\/j.jstrokecerebrovasdis.2016.05.035","article-title":"Safety and efficacy of wingspan stenting for severe symptomatic atherosclerotic stenosis of the middle cerebral artery: analysis of 278 continuous cases","volume":"25","author":"Zhao","year":"2016","journal-title":"J Stroke Cerebrovasc Dis"},{"issue":"9245","key":"bib14-20231101","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/S0140-6736(00)03262-1","article-title":"Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis","volume":"356","author":"Koster","year":"2000","journal-title":"Lancet North Am Ed"},{"issue":"2","key":"bib15-20231101","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/DER.0b013e3182819c51","article-title":"North American Contact Dermatitis Group patch test results","volume":"24","author":"Warshaw","year":"2013","journal-title":"Dermatitis"},{"issue":"4","key":"bib16-20231101","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1067\/mhj.2003.7","article-title":"Nickel release after implantation of the Amplatzer occluder","volume":"145","author":"Ries","year":"2003","journal-title":"Am Heart J"},{"issue":"8","key":"bib17-20231101","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1007\/s00234-012-1048-2","article-title":"Reversible intracranial parenchymal changes in MRI after MCA aneurysm treatment with stent-assisted coiling technique; possible nickel allergy","volume":"54","author":"Ulus","year":"2012","journal-title":"Neuroradiology"},{"issue":"4","key":"bib18-20231101","first-page":"176","article-title":"North American Contact Dermatitis Group patch-test results, 2001\u20132002 study period","volume":"15","author":"Pratt","year":"2004","journal-title":"Dermatitis"},{"issue":"1","key":"bib19-20231101","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1600-0536.2011.01971.x","article-title":"Hypersensitivity reactions to metallic implants - diagnostic algorithm and suggested patch test series for clinical use","volume":"66","author":"Schalock","year":"2012","journal-title":"Contact Dermatitis"},{"issue":"3","key":"bib20-20231101","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1002\/(SICI)1097-4636(19990605)45:3<251::AID-JBM13>3.0.CO;2-5","article-title":"Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cellsin vitro","volume":"45","author":"Wataha","year":"1999","journal-title":"J Biomed Mater Res"},{"issue":"9","key":"bib21-20231101","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1097\/PAS.0b013e318165582a","article-title":"Complications of endovascular polymers associated with vascular introducer sheaths and metallic coils in 3 patients, with literature review","volume":"32","author":"Fealey","year":"2008","journal-title":"Am J Surg Pathol"},{"issue":"11","key":"bib22-20231101","doi-asserted-by":"crossref","first-page":"2121","DOI":"10.3174\/ajnr.A4415","article-title":"Foreign body emboli following cerebrovascular interventions: clinical, radiographic, and histopathologic features","volume":"36","author":"Shapiro","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"bib23-20231101","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s00234-014-1440-1","article-title":"Suspected cerebral foreign body granuloma following endovascular treatment of intracranial aneurysm: imaging features","volume":"57","author":"Minks","year":"2015","journal-title":"Neuroradiology"},{"issue":"3","key":"bib24-20231101","first-page":"28","article-title":"Neurological changes with abnormal brain reactivity following coiling of cerebral aneurysm. Possible reactivity to endovascular devices and material","volume":"8","author":"Grewal","year":"2015","journal-title":"J Vascul Interv Neurol"},{"issue":"1","key":"bib25-20231101","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1177\/1591019915609171","article-title":"Cerebral foreign body reaction after carotid aneurysm stenting","volume":"22","author":"Lorentzen","year":"2016","journal-title":"Interv Neuroradiol"},{"issue":"2","key":"bib26-20231101","doi-asserted-by":"crossref","first-page":"365","DOI":"10.3171\/2013.11.JNS131599","article-title":"Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization Device","volume":"120","author":"Hu","year":"2014","journal-title":"JNS"}],"container-title":["Operative Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ons\/article-pdf\/19\/1\/76\/33348134\/opz299.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.ovid.com\/10.1093\/ons\/opz299","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:54:03Z","timestamp":1786121643000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1093\/ons\/opz299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,4]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1093\/ons\/opz299","relation":{},"ISSN":["2332-4252","2332-4260"],"issn-type":[{"value":"2332-4252","type":"print"},{"value":"2332-4260","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,4]]}}}