{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T14:31:49Z","timestamp":1783607509732,"version":"3.55.0"},"reference-count":32,"publisher":"Oxford University Press (OUP)","issue":"1193","license":[{"start":{"date-parts":[[2024,9,18]],"date-time":"2024-09-18T00:00:00Z","timestamp":1726617600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"Financial Science and Technology Project of Hunan Province, China","award":["422000008"],"award-info":[{"award-number":["422000008"]}]},{"name":"Hunan Province Nature Science Foundation, China","award":["2021JJ30911"],"award-info":[{"award-number":["2021JJ30911"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,2,19]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>The Tubridge flow diverter (TFD) was recently developed to treat intracranial aneurysm (IA). In this study, we aimed to assess the safety and efficacy of this novel device.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>A retrospective cohort of consecutive patients with IA was recruited between June 2017 and February 2022. The studied outcomes were perioperative complications, clinical quality of life, and angiographic IA occlusion. Multivariate logistic regression was performed to explore the potential predictors of perioperative stroke events and IA occlusion. A comprehensive literature review was conducted across five databases for evidence synthesis.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Among the patients with IA in our cohort, 144 underwent successful TFD implantation. Postoperative stroke was observed in 11 (7.6%) patients, and 130 (90.3%) patients were discharged with modified Rankin scales (mRS) of \u22642. In the last clinical follow-up (mean, 16.9\u00a0months), 96.6% of the patients reported a satisfactory quality of life (mRS \u22642). IA occlusion was observed in 84.6% of the patients at the last angiographic follow-up (mean, 10.4\u00a0months). Aneurysmal subarachnoid hemorrhage [odds ratio (OR), 6.98; 95% confidence interval (CI), 1.11\u201343.91] and giant IA (OR, 5.63; 95% CI, 1.15\u201327.48) were associated with perioperative stroke events. The evidence synthesis found high rates of satisfactory quality of life (rate, 98.8%; 95% CI, 97.1\u201399.9%) and IA obliteration (rate, 78.5%; 95% CI, 74.0\u201382.7%) after TFD treatment. The pooled complication rate was 13.6% (95% CI, 10.9\u201316.5%).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>This study identified a high rate of IA occlusion in patients who received TFD treatment. These patients also reported a satisfactory quality of life. Further studies in larger prospective cohorts with longer follow-up periods are warranted to verify our findings.<\/jats:p>\n                  <jats:p>Key message What is already known on this topic\u00a0 Flow diverter (FD) devices are an optimal tool to modify hemodynamics and treat intracranial aneurysms (IAs). However, the safety and efficacy of a novel self-expanding FD, namely the Tubridge flow diverter (TFD), remain to be fully established owing to the short-term follow-up periods and limited sample size of existing studies. What this study adds\u00a0 In our cohort of patients who received TFD treatment, 96.6% of patients reported satisfactory quality of life at the last clinical follow-up (mean, 16.9\u00a0months); and 84.6% of IAs were successfully occluded at the last angiographic follow-up (mean, 10.4\u00a0months). Our comprehensive review and evidence synthesis of existing studies on TFD found high rates of satisfactory quality of life (98.8%; 97.1\u201399.9%) and IA obliteration (78.5%; 74.0\u201382.7%). How this study might affect research, practice or policy\u00a0 TFD demonstrated satisfactory performance in the treatment of IAs in our cohort. Studies with larger prospective cohorts and longer follow-up periods are warranted to further investigate this promising novel approach.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/postmj\/qgae109","type":"journal-article","created":{"date-parts":[[2024,9,18]],"date-time":"2024-09-18T00:02:18Z","timestamp":1726617738000},"page":"196-202","source":"Crossref","is-referenced-by-count":3,"title":["Treatment of intracranial aneurysms using the Tubridge flow diverter"],"prefix":"10.1093","volume":"101","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9665-4222","authenticated-orcid":false,"given":"Dun","family":"Yuan","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, XiangYa Hospital, Central South University , Changsha 410008,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-8918-3670","authenticated-orcid":false,"given":"Nibu","family":"Zhenmei","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, XiangYa Hospital, Central South University , Changsha 410008,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6775-8399","authenticated-orcid":false,"given":"Yuxin","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Epidemiology and Health Statistics, XiangYa School of Public Health, Central South University , Changsha 410013,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8402-4250","authenticated-orcid":false,"given":"Fang","family":"Cao","sequence":"additional","affiliation":[{"name":"Department of Epidemiology and Health Statistics, XiangYa School of Public Health, Central South University , Changsha 410013,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3803-4068","authenticated-orcid":false,"given":"Junyu","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, XiangYa Hospital, Central South University , Changsha 410008,","place":["China"]},{"name":"Department of Pharmacology, Kyoto University Graduate School of Medicine , Kyoto 606-8501,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1570-0854","authenticated-orcid":false,"given":"Weixi","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, XiangYa Hospital, Central South University , Changsha 410008,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7593-8453","authenticated-orcid":false,"given":"Yifeng","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, XiangYa Hospital, Central South University , Changsha 410008,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6067-1613","authenticated-orcid":false,"given":"Junxia","family":"Yan","sequence":"additional","affiliation":[{"name":"Department of Epidemiology and Health Statistics, XiangYa School of Public Health, Central South University , Changsha 410013,","place":["China"]},{"name":"Hunan Provincial Key Laboratory of Clinical Epidemiology, XiangYa School of Public Health, Central South University , Changsha 410013,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,9,18]]},"reference":[{"key":"2025022013484591700_ref1","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1001\/jamaneurol.2019.0006","article-title":"Worldwide incidence of aneurysmal subarachnoid hemorrhage according to region, time period, blood pressure, and smoking prevalence in the population: a systematic review and meta-analysis","volume":"76","author":"Etminan","year":"2019","journal-title":"JAMA Neurol"},{"key":"2025022013484591700_ref2","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1097\/JS9.0000000000000762","article-title":"Flow-diverter stents in intracranial aneurysm treatment: impact on covered cerebral artery branches","volume":"110","author":"Liu","year":"2023","journal-title":"Int J Surg"},{"key":"2025022013484591700_ref3","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1136\/neurintsurg-2022-018941","article-title":"Bioresorbable flow diverters for the treatment of intracranial aneurysms: review of current literature and future directions","volume":"15","author":"Oliver","year":"2023","journal-title":"J Neurointerv Surg."},{"key":"2025022013484591700_ref4","doi-asserted-by":"publisher","first-page":"807","DOI":"10.3174\/ajnr.A5619","article-title":"Parent artery reconstruction for large or giant cerebral aneurysms using the Tubridge flow diverter: a multicenter, randomized, controlled clinical trial (PARAT)","volume":"39","author":"Liu","year":"2018","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025022013484591700_ref5","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1007\/s10143-023-02100-6","article-title":"A novel flow diverter device (Tubridge) for the treatment of intracranial aneurysms: a systematic review and meta-analysis","volume":"46","author":"Fan","year":"2023","journal-title":"Neurosurg Rev"},{"key":"2025022013484591700_ref6","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1001\/jamasurg.2021.0528","article-title":"STROBE reporting guidelines for observational studies","volume":"156","author":"Ghaferi","year":"2021","journal-title":"JAMA Surg"},{"key":"2025022013484591700_ref7","doi-asserted-by":"publisher","first-page":"105918","DOI":"10.1016\/j.ijsu.2021.105918","article-title":"PRISMA 2020 statement: what's new and the importance of reporting guidelines","volume":"88","author":"Sohrabi","year":"2021","journal-title":"Int J Surg"},{"key":"2025022013484591700_ref8","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1136\/neurintsurg-2014-011258","article-title":"An update to the Raymond-Roy Occlusion Classification of intracranial aneurysms treated with coil embolization","volume":"7","author":"Mascitelli","year":"2015","journal-title":"J Neurointerv Surg"},{"key":"2025022013484591700_ref9","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1161\/01.cir.97.16.1632","article-title":"Thrombolysis for acute myocardial infarction","volume":"97","author":"White","year":"1998","journal-title":"Circulation"},{"key":"2025022013484591700_ref10","doi-asserted-by":"publisher","first-page":"909","DOI":"10.3760\/cma.j.issn.1001-2346.2019.09.009","article-title":"Application of domestic Tubridge flow diverter in the treatment of unruptured intracranial aneurysms","volume":"35","author":"Li","year":"2019","journal-title":"Chin Neurosurg J"},{"key":"2025022013484591700_ref11","doi-asserted-by":"publisher","first-page":"900","DOI":"10.3760\/cma.j.issn.1001-2346.2019.09.007","article-title":"Treatment of intracranial aneurysms with Tubridge flow diverter: a single-center experience","volume":"35","author":"Lv","year":"2019","journal-title":"Chin Neurosurg J"},{"key":"2025022013484591700_ref12","doi-asserted-by":"publisher","first-page":"771","DOI":"10.3760\/cma.j.cn115354-20210224-00125","article-title":"Flow diverter device Tubridge in intracranial complex aneurysms: an efficacy and safety analysis","volume-title":"Chin J Neuromed","author":"Gao","year":"2021"},{"key":"2025022013484591700_ref13","doi-asserted-by":"publisher","first-page":"160","DOI":"10.3877\/cma.j.issn.2095-5782.2021.02.008","article-title":"Preliminary application of domestic Tubridge flow diverter in the treatment of vertebral artery dissecting aneurysm","volume-title":"Chin J Inter Rad (Electronic Edition)","author":"Sun","year":"2021"},{"key":"2025022013484591700_ref14","doi-asserted-by":"publisher","first-page":"1014596","DOI":"10.3389\/fneur.2022.1014596","article-title":"A multicenter retrospective controlled study of the Pipeline\u2122 and Tubridge\u2122 flow diverter devices for intracranial wide-necked aneurysms","volume":"13","author":"Cai","year":"2022","journal-title":"Front Neurol"},{"key":"2025022013484591700_ref15","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.jocn.2021.11.030","article-title":"Flow diversion for aneurysms beyond the circle of Willis: a preliminary experience","volume":"95","author":"Li","year":"2022","journal-title":"J Clin Neurosci"},{"key":"2025022013484591700_ref16","doi-asserted-by":"publisher","first-page":"974354","DOI":"10.3389\/fneur.2022.974354","article-title":"Tubridge flow diverter alone vs. Tubridge flow diverter and coils for the treatment of intracranial aneurysms: a propensity score matching analysis","volume":"13","author":"Shi","year":"2022","journal-title":"Front Neurol"},{"key":"2025022013484591700_ref17","doi-asserted-by":"publisher","first-page":"990308","DOI":"10.3389\/fneur.2022.990308","article-title":"Use of flow diverter device in basilar artery for aneurysm treatment: case series and literature review","volume":"13","author":"Wang","year":"2022","journal-title":"Front Neurol"},{"key":"2025022013484591700_ref18","volume-title":"The Retrospective Analysis of Domestic Flow Diverter Tubridge in the Treatment of Intracranial Aneurysms [D]","author":"Liu","year":"2021"},{"key":"2025022013484591700_ref19","doi-asserted-by":"publisher","first-page":"1054631","DOI":"10.3389\/fneur.2023.1054631","article-title":"Tubridge flow diverter for the treatment of small and medium aneurysms","volume":"14","author":"Xie","year":"2023","journal-title":"Front Neurol"},{"key":"2025022013484591700_ref20","doi-asserted-by":"publisher","first-page":"112","DOI":"10.3760\/cma.j.cn112050-20220406-00181","article-title":"Analysis of therapeutic effect of Tubridge flow diverter in the treatment of intracranial aneurysms","volume":"39","author":"Jia","year":"2023","journal-title":"Chin Neurosurg J"},{"key":"2025022013484591700_ref21","doi-asserted-by":"publisher","first-page":"31","DOI":"10.11817\/j.issn.1673-9248.2023.01.006","article-title":"Flow-diverters in treating unruptured intracranial aneurysms: a study of efficacy and influencing factors","volume":"17","author":"Lian","year":"2023","journal-title":"Chinese J Cerebrovasc Dis (Electronic Edition)"},{"key":"2025022013484591700_ref22","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s41016-023-00337-0","article-title":"Pipeline versus Tubridge in the treatment of unruptured posterior circulation aneurysms","volume":"9","author":"Jin","year":"2023","journal-title":"Chin Neurosurg J"},{"key":"2025022013484591700_ref23","doi-asserted-by":"publisher","first-page":"S36","DOI":"10.1093\/neuros\/nyz345","article-title":"Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes","volume":"86","author":"Chancellor","year":"2020","journal-title":"Neurosurgery"},{"key":"2025022013484591700_ref24","doi-asserted-by":"publisher","first-page":"e938","DOI":"10.1016\/j.wneu.2018.03.120","article-title":"Predicting successful treatment of intracranial aneurysms with the pipeline embolization device through meta-regression","volume":"114","author":"Beydoun","year":"2018","journal-title":"World Neurosurg"},{"key":"2025022013484591700_ref25","doi-asserted-by":"publisher","first-page":"222","DOI":"10.5469\/neuroint.2021.00234","article-title":"Silk\u00ae flow diverter device for intracranial aneurysm treatment: a systematic review and meta-analysis","volume":"16","author":"Florez","year":"2021","journal-title":"Neurointervention"},{"key":"2025022013484591700_ref26","doi-asserted-by":"publisher","first-page":"810","DOI":"10.3390\/brainsci12060810","article-title":"Surpass evolve flow diverter for the treatment of intracranial aneurysm: a systematic review","volume":"12","author":"Issa","year":"2022","journal-title":"Brain Sci"},{"key":"2025022013484591700_ref27","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1136\/neurintsurg-2021-018390","article-title":"A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment","volume":"14","author":"Monteiro","year":"2022","journal-title":"J Neurointerv Surg"},{"key":"2025022013484591700_ref28","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1136\/jnis-2023-020514","article-title":"Phenox HPC and Phenox flow modulation devices for the endovascular treatment of intracranial aneurysms: a systematic review and meta-analysis","volume":"16","author":"Bilgin","year":"2023","journal-title":"J Neurointerv Surg."},{"key":"2025022013484591700_ref29","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1177\/1971400915621321","article-title":"Flow-diverter devices in the treatment of intracranial aneurysms: a meta-analysis and systematic review","volume":"29","author":"Lv","year":"2016","journal-title":"Neuroradiol J"},{"key":"2025022013484591700_ref30","doi-asserted-by":"publisher","first-page":"108","DOI":"10.3174\/ajnr.A4111","article-title":"International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study","volume":"36","author":"Kallmes","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"2025022013484591700_ref31","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1136\/neurintsurg-2021-017445","article-title":"Postoperative occlusion degree after flow-diverter placement with adjunctive coiling: analysis of complications","volume":"14","author":"Kang","year":"2022","journal-title":"J Neurointerv Surg"},{"key":"2025022013484591700_ref32","doi-asserted-by":"publisher","first-page":"e935613-1\u2013e935613-10","DOI":"10.12659\/MSM.935613","article-title":"High-resolution magnetic resonance imaging (HR-MRI) evaluation of the distribution and characteristics of intra-aneurysm thrombosis to improve clinical diagnosis of thrombotic intracranial aneurysm","author":"Gu","year":"2022","journal-title":"Med Sci Monit"}],"container-title":["Postgraduate Medical Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/pmj\/article-pdf\/101\/1193\/196\/59157269\/qgae109.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/pmj\/article-pdf\/101\/1193\/196\/59157269\/qgae109.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,20]],"date-time":"2025-02-20T13:49:15Z","timestamp":1740059355000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/pmj\/article\/101\/1193\/196\/7759641"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,18]]},"references-count":32,"journal-issue":{"issue":"1193","published-online":{"date-parts":[[2024,9,18]]},"published-print":{"date-parts":[[2025,2,19]]}},"URL":"https:\/\/doi.org\/10.1093\/postmj\/qgae109","relation":{},"ISSN":["0032-5473","1469-0756"],"issn-type":[{"value":"0032-5473","type":"print"},{"value":"1469-0756","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,3]]},"published":{"date-parts":[[2024,9,18]]}}}