{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T18:33:52Z","timestamp":1791916432358,"version":"4.3.4"},"reference-count":65,"publisher":"Oxford University Press (OUP)","license":[{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"vor","delay-in-days":163,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52130302"],"award-info":[{"award-number":["52130302"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,22]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Iron-based biodegradable stents hold significant promise for percutaneous coronary intervention. Our previous study has revealed that a polylactide (PLA) coating can not only accelerate iron corrosion but also mitigate corrosion inhomogeneity, presenting a metal-polymer composite stent (MPS). Nevertheless, current understanding of how PLA coating parameters regulate iron corrosion remains limited. This article represents the systematic and quantitative in vitro investigation into the effects of coating thickness, molecular weight, and end group of PLA on the corrosion rate and inhomogeneity of an iron substrate under biomimetic conditions. By theoretically developing an equation set to quantify random degradation with time-dependent inhomogeneity and experimentally combining immersion corrosion tests with electrochemical analysis, we elucidate the spatiotemporal evolution of iron corrosion under different coating parameters. Our findings provide a crucial foundation for optimizing the degradation behavior of MPS and stimulating the design of other biodegradable materials.<\/jats:p>","DOI":"10.1093\/rb\/rbag126","type":"journal-article","created":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T16:07:44Z","timestamp":1781453264000},"source":"Crossref","is-referenced-by-count":1,"title":["Effects of molecular weight, end group of polylactide and coating thickness on corrosion rate and inhomogeneity of iron under biomimetic conditions"],"prefix":"10.1093","volume":"13","author":[{"given":"Wenjie","family":"Wu","sequence":"first","affiliation":[{"name":"State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University , Shanghai 200438,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiandong","family":"Ding","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University , Shanghai 200438,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,13]]},"reference":[{"key":"2026070913270950600_rbag126-B1","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1016\/S0140-6736(07)60853-8","article-title":"Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents:: a prospective, non-randomised multicentre trial","volume":"369","author":"Erbel","year":"2007","journal-title":"Lancet"},{"key":"2026070913270950600_rbag126-B2","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1253\/circj.CJ-10-1135","article-title":"Bioresorbable scaffold technologies","volume":"75","author":"Onuma","year":"2011","journal-title":"Circ J"},{"key":"2026070913270950600_rbag126-B3","doi-asserted-by":"crossref","first-page":"2701","DOI":"10.1093\/eurheartj\/ehw196","article-title":"Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial","volume":"37","author":"Haude","year":"2016","journal-title":"Eur Heart J"},{"key":"2026070913270950600_rbag126-B4","doi-asserted-by":"crossref","first-page":"rbad112","DOI":"10.1093\/rb\/rbad112","article-title":"Effects of serum proteins on corrosion rates and product bioabsorbability of biodegradable metals","volume":"11","author":"Zhang","year":"2024","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B5","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.msec.2018.04.100","article-title":"Biodegradable stents for coronary artery disease treatment: recent advances and future perspectives","volume":"91","author":"Hu","year":"2018","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"2026070913270950600_rbag126-B6","doi-asserted-by":"crossref","first-page":"119414","DOI":"10.1016\/j.biomaterials.2019.119414","article-title":"In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy","volume":"221","author":"Chen","year":"2019","journal-title":"Biomaterials"},{"key":"2026070913270950600_rbag126-B7","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1038\/s41578-019-0150-z","article-title":"Design of biodegradable, implantable devices towards clinical translation","volume":"5","author":"Li","year":"2019","journal-title":"Nat Rev Mater"},{"key":"2026070913270950600_rbag126-B8","first-page":"231","article-title":"Biosafety and efficacy evaluation of a biodegradable Zn-Cu-Mn stent: a long-term study in porcine coronary artery","volume":"45","author":"Qian","year":"2025","journal-title":"Bioact Mater"},{"key":"2026070913270950600_rbag126-B9","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/S0140-6736(12)61765-6","article-title":"Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial","volume":"381","author":"Haude","year":"2013","journal-title":"Lancet"},{"key":"2026070913270950600_rbag126-B10","doi-asserted-by":"crossref","first-page":"e160","DOI":"10.4244\/EIJ-D-15-00371","article-title":"Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de novo coronary lesions: 3-year results of the prospective, multicentre, first-in-man BIOSOLVE-I trial","volume":"12","author":"Haude","year":"2016","journal-title":"EuroIntervention"},{"key":"2026070913270950600_rbag126-B11","doi-asserted-by":"crossref","first-page":"122411","DOI":"10.1016\/j.biomaterials.2023.122411","article-title":"Hybrid interpenetrating network of polyester coronary stent with tunable biodegradation and mechanical properties","volume":"304","author":"Shi","year":"2024","journal-title":"Biomaterials"},{"key":"2026070913270950600_rbag126-B12","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.matlet.2010.10.068","article-title":"In vitro investigation of Fe30Mn6Si shape memory alloy as potential biodegradable metallic material","volume":"65","author":"Liu","year":"2011","journal-title":"Mater Lett"},{"key":"2026070913270950600_rbag126-B13","first-page":"1028","article-title":"In vivo degradation and endothelialization of an iron bioresorbable scaffold","volume":"6","author":"Lin","year":"2021","journal-title":"Bioact Mater"},{"key":"2026070913270950600_rbag126-B14","doi-asserted-by":"crossref","first-page":"rbae002","DOI":"10.1093\/rb\/rbae002","article-title":"Fe-Zn alloy, a new biodegradable material capable of reducing ROS and inhibiting oxidative stress","volume":"11","author":"Yang","year":"2024","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B15","doi-asserted-by":"crossref","first-page":"rbaf041","DOI":"10.1093\/rb\/rbaf041","article-title":"A novel iron bioresorbable scaffold: a potential strategy for pulmonary artery stenosis","volume":"12","author":"Qin","year":"2025","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B16","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1038\/nrcardio.2016.151","article-title":"Bioresorbable vascular scaffolds\u2013basic concepts and clinical outcome","volume":"13","author":"Indolfi","year":"2016","journal-title":"Nat Rev Cardiol"},{"key":"2026070913270950600_rbag126-B17","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1038\/s41569-018-0124-7","article-title":"Fully bioresorbable vascular scaffolds: lessons learned and future directions","volume":"16","author":"Jinnouchi","year":"2019","journal-title":"Nat Rev Cardiol"},{"key":"2026070913270950600_rbag126-B18","doi-asserted-by":"crossref","first-page":"eabf0614","DOI":"10.1126\/sciadv.abf0614","article-title":"PDLLA-Zn-nitrided Fe bioresorbable scaffold with 53-\u03bcm-thick metallic struts and tunable multistage biodegradation function","volume":"7","author":"Shen","year":"2021","journal-title":"Sci Adv"},{"key":"2026070913270950600_rbag126-B19","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/1475-925X-5-40","article-title":"Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling","volume":"5","author":"LaDisa","year":"2006","journal-title":"Biomed Eng Online"},{"key":"2026070913270950600_rbag126-B20","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1161\/CIRCULATIONAHA.106.632687","article-title":"Cardiology is flow","volume":"113","author":"Richter","year":"2006","journal-title":"Circulation"},{"issue":"Suppl V","key":"2026070913270950600_rbag126-B21","doi-asserted-by":"crossref","first-page":"V159","DOI":"10.4244\/EIJV11SVA39","article-title":"Pathological aspects of bioresorbable stent implantation","volume":"11","author":"Sanchez","year":"2015","journal-title":"EuroIntervention"},{"key":"2026070913270950600_rbag126-B22","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1016\/j.actbio.2009.07.039","article-title":"Design strategy for biodegradable Fe-based alloys for medical applications","volume":"6","author":"Schinhammer","year":"2010","journal-title":"Acta Biomater"},{"key":"2026070913270950600_rbag126-B23","doi-asserted-by":"crossref","first-page":"1852","DOI":"10.1016\/j.actbio.2009.11.025","article-title":"Fe-Mn alloys for metallic biodegradable stents: degradation and cell viability studies","volume":"6","author":"Hermawan","year":"2010","journal-title":"Acta Biomater"},{"key":"2026070913270950600_rbag126-B24","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/j.actbio.2010.11.001","article-title":"Effects of alloying elements (Mn, Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron","volume":"7","author":"Liu","year":"2011","journal-title":"Acta Biomater"},{"key":"2026070913270950600_rbag126-B25","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.actbio.2019.05.033","article-title":"Accelerated biodegradation and improved mechanical performance of pure iron through surface grain refinement","volume":"98","author":"Bagherifard","year":"2019","journal-title":"Acta Biomater"},{"key":"2026070913270950600_rbag126-B26","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1038\/s41524-018-0089-4","article-title":"Phase-field model of pitting corrosion kinetics in metallic materials","volume":"4","author":"Ansari","year":"2018","journal-title":"npj Comput Mater"},{"key":"2026070913270950600_rbag126-B27","doi-asserted-by":"crossref","first-page":"111761","DOI":"10.1016\/j.mtcomm.2025.111761","article-title":"Multiscale modeling of texture effects on pitting corrosion of iron","volume":"43","author":"Jamebozorgi","year":"2025","journal-title":"Mater Today Commun"},{"key":"2026070913270950600_rbag126-B28","first-page":"1400","article-title":"Incidence and imaging outcomes of acute scaffold disruption and late structural discontinuity after implantation of the absorb everolimus-eluting fully bioresorbable vascular scaffold: optical coherence tomography assessment in the ABSORB Cohort B Trial (a clinical evaluation of the bioabsorbable everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions)","volume":"7","author":"Onuma","year":"2014","journal-title":"JACC: Cardiovasc Interv"},{"key":"2026070913270950600_rbag126-B29","first-page":"1115","article-title":"Incidence and clinical outcomes of stent fractures on the basis of 6,555 patients and 16,482 drug-eluting stents from 4 centers","volume":"9","author":"Kan","year":"2016","journal-title":"JACC: Cardiovasc Interv"},{"key":"2026070913270950600_rbag126-B30","doi-asserted-by":"crossref","first-page":"2330","DOI":"10.1016\/j.jacc.2017.09.014","article-title":"Mechanisms of very late bioresorbable scaffold thrombosis: the INVEST registry","volume":"70","author":"Yamaji","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"2026070913270950600_rbag126-B31","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1038\/s41569-018-0118-5","article-title":"Predictors of stent thrombosis and their implications for clinical practice","volume":"16","author":"Gori","year":"2019","journal-title":"Nat Rev Cardiol"},{"key":"2026070913270950600_rbag126-B32","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1021\/acsami.7b15206","article-title":"Strategy of metal-polymer composite stent to accelerate biodegradation of iron-based biomaterials","volume":"10","author":"Qi","year":"2018","journal-title":"ACS Appl Mater Interfaces"},{"key":"2026070913270950600_rbag126-B33","doi-asserted-by":"crossref","first-page":"15703","DOI":"10.1021\/acsami.0c00971","article-title":"Long-term efficacy of biodegradable metal-polymer composite stents after the first and the second implantations into porcine coronary arteries","volume":"12","author":"Li","year":"2020","journal-title":"ACS Appl Mater Interfaces"},{"key":"2026070913270950600_rbag126-B34","doi-asserted-by":"crossref","first-page":"2201740","DOI":"10.1002\/adhm.202201740","article-title":"A biodegradable metal-polymer composite stent safe and effective on physiological and serum-containing biomimetic conditions","volume":"11","author":"Zhang","year":"2022","journal-title":"Adv Healthcare Mater"},{"key":"2026070913270950600_rbag126-B35","doi-asserted-by":"crossref","first-page":"7903","DOI":"10.1038\/s41467-024-52288-4","article-title":"Maglev-fabricated long and biodegradable stent for interventional treatment of peripheral vessels","volume":"15","author":"Zhang","year":"2024","journal-title":"Nat Commun"},{"key":"2026070913270950600_rbag126-B36","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1021\/acsami.8b17125","article-title":"Mechanism of acceleration of iron corrosion by a polylactide coating","volume":"11","author":"Qi","year":"2019","journal-title":"ACS Appl Mater Interfaces"},{"key":"2026070913270950600_rbag126-B37","doi-asserted-by":"crossref","first-page":"107301","DOI":"10.1016\/j.porgcoat.2022.107301","article-title":"Enhancing the corrodibility of biodegradable iron and zinc using poly (lactic) acid (PLA) coating for temporary medical implant applications","volume":"174","author":"Wang","year":"2023","journal-title":"Prog Org Coat"},{"key":"2026070913270950600_rbag126-B38","doi-asserted-by":"crossref","first-page":"144645","DOI":"10.1016\/j.electacta.2024.144645","article-title":"The mechanism of gold nanoparticle-enhanced corrosion acceleration of polylactide (PLA)-coated biodegradable iron and zinc","volume":"499","author":"Wang","year":"2024","journal-title":"Electrochim Acta"},{"key":"2026070913270950600_rbag126-B39","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.matdes.2015.11.045","article-title":"Design and characterization of a novel biocorrodible iron-based drug-eluting coronary scaffold","volume":"91","author":"Lin","year":"2016","journal-title":"Mater Des"},{"key":"2026070913270950600_rbag126-B40","first-page":"222","article-title":"First-in-human evaluation of a novel ultrathin sirolimus-eluting iron bioresorbable scaffold: 3-year outcomes of the IBS-FIM trial","volume":"19","author":"Gao","year":"2023","journal-title":"EuroIntervention"},{"key":"2026070913270950600_rbag126-B41","doi-asserted-by":"crossref","first-page":"2117","DOI":"10.1016\/j.jacc.2025.12.024","article-title":"Sirolimus-eluting iron bioresorbable scaffolds vs everolimus-eluting stents for percutaneous coronary intervention: a randomized trial (IRONMAN II)","volume":"87","author":"Gao","year":"2026","journal-title":"J Am Coll Cardiol"},{"key":"2026070913270950600_rbag126-B42","doi-asserted-by":"crossref","first-page":"2350","DOI":"10.1016\/j.matdes.2010.12.016","article-title":"Influence of surface roughness on the corrosion behaviour of magnesium alloy","volume":"32","author":"Walter","year":"2011","journal-title":"Mater Des"},{"key":"2026070913270950600_rbag126-B43","doi-asserted-by":"crossref","first-page":"e1903080","DOI":"10.1002\/adma.201903080","article-title":"Biocorrosion zoomed in: evidence for dealloying of nanometric intermetallic particles in magnesium alloys","volume":"31","author":"Cihova","year":"2019","journal-title":"Adv Mater"},{"key":"2026070913270950600_rbag126-B44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jmst.2022.03.006","article-title":"Microstructure refinement in biodegradable Zn-Cu-Ca alloy for enhanced mechanical properties, degradation homogeneity, and strength retention in simulated physiological condition","volume":"125","author":"Yang","year":"2022","journal-title":"J Mater Sci Technol"},{"key":"2026070913270950600_rbag126-B45","doi-asserted-by":"crossref","first-page":"rbad007","DOI":"10.1093\/rb\/rbad007","article-title":"Establishment of coverage-mass equation to quantify the corrosion inhomogeneity and examination of medium effects on iron corrosion","volume":"10","author":"Li","year":"2023","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B46","doi-asserted-by":"publisher","DOI":"10.1007\/s40843-026-4230-8","article-title":"A set of equations for random degradation quantifies the role of polymer coatings in mitigating the acquired heterogeneity of corrodible metals for biodegradable stents","author":"Li","year":"2026","journal-title":"Sci China Mater"},{"key":"2026070913270950600_rbag126-B47","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1063\/1.1750380","article-title":"Kinetics of phase change. I general theory","volume":"7","author":"Avrami","year":"1939","journal-title":"J Chem Phys"},{"key":"2026070913270950600_rbag126-B48","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.corsci.2016.07.027","article-title":"Strengthened corrosion control of poly (lactic acid) (PLA) and poly (\u03b5-caprolactone) (PCL) polymer-coated magnesium by imbedded hydrophobic stearic acid (SA) thin layer","volume":"112","author":"Zhang","year":"2016","journal-title":"Corros Sci"},{"key":"2026070913270950600_rbag126-B49","doi-asserted-by":"crossref","first-page":"145379","DOI":"10.1016\/j.apsusc.2020.145379","article-title":"Influence of albumin interaction on corrosion resistance of sintered iron biomaterials with polyethyleneimine coating","volume":"509","author":"Ori\u0148akov\u00e1","year":"2020","journal-title":"Appl Surf Sci"},{"key":"2026070913270950600_rbag126-B50","doi-asserted-by":"crossref","first-page":"101556","DOI":"10.1016\/j.progpolymsci.2022.101556","article-title":"The influence of the functional end groups on the properties of polylactide-based materials","volume":"130","author":"Kost","year":"2022","journal-title":"Prog Polym Sci"},{"key":"2026070913270950600_rbag126-B51","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1038\/nature08603","article-title":"Biomaterial systems for mechanosensing and actuation","volume":"462","author":"Fratzl","year":"2009","journal-title":"Nature"},{"key":"2026070913270950600_rbag126-B52","doi-asserted-by":"crossref","first-page":"rbac098","DOI":"10.1093\/rb\/rbac098","article-title":"Recent advances in regenerative biomaterials","volume":"9","author":"Cao","year":"2022","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B53","doi-asserted-by":"crossref","first-page":"rbad056","DOI":"10.1093\/rb\/rbad056","article-title":"Biaxial stretching of polytetrafluoroethylene in industrial scale to fabricate medical ePTFE membrane with node-fibril microstructure","volume":"10","author":"Wang","year":"2023","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B54","doi-asserted-by":"crossref","first-page":"rbaf016","DOI":"10.1093\/rb\/rbaf016","article-title":"Biodegradable polymeric occluder with controllable locking structure for closure of atrial septal defect via interventional treatment","volume":"12","author":"Shi","year":"2025","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B55","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1038\/s41551-025-01420-w","article-title":"Strategies for the vascular patterning of engineered tissues for organ repair","volume":"9","author":"Janson","year":"2025","journal-title":"Nat Biomed Eng"},{"key":"2026070913270950600_rbag126-B56","doi-asserted-by":"crossref","first-page":"121208","DOI":"10.1016\/j.biomaterials.2021.121208","article-title":"Surface modification to enhance cell migration on biomaterials and its combination with 3D structural design of occluders to improve interventional treatment of heart diseases","volume":"279","author":"Shen","year":"2021","journal-title":"Biomaterials"},{"key":"2026070913270950600_rbag126-B57","doi-asserted-by":"crossref","first-page":"rbae027","DOI":"10.1093\/rb\/rbae027","article-title":"In vitro and in vivo degradation, biocompatibility and bone repair performance of strontium-doped montmorillonite coating on Mg-Ca alloy","volume":"11","author":"Sun","year":"2024","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B58","doi-asserted-by":"crossref","first-page":"rbae001","DOI":"10.1093\/rb\/rbae001","article-title":"Advances in functional coatings on biliary stents","volume":"11","author":"Yang","year":"2024","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B59","doi-asserted-by":"crossref","first-page":"rbae102","DOI":"10.1093\/rb\/rbae102","article-title":"Biomimetic ROS-responsive hyaluronic acid nanoparticles loaded with methotrexate for targeted anti-atherosclerosis","volume":"11","author":"Li","year":"2024","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B60","doi-asserted-by":"crossref","first-page":"e2501264122","DOI":"10.1073\/pnas.2501264122","article-title":"Nanoscale distribution of bioactive ligands on biomaterials regulates cell mechanosensing through translocation of actin into the nucleus","volume":"122","author":"Liu","year":"2025","journal-title":"Proc Natl Acad Sci U S A"},{"key":"2026070913270950600_rbag126-B61","doi-asserted-by":"crossref","first-page":"rbaf043","DOI":"10.1093\/rb\/rbaf043","article-title":"Y-shaped DNA as a dynamic self-assembly nanomaterial for phenotype-specific regulation of stem cell differentiation on the gene level","volume":"12","author":"Liu","year":"2025","journal-title":"Regen Biomater"},{"key":"2026070913270950600_rbag126-B62","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1136\/heart.86.5.563","article-title":"A novel approach to temporary stenting:: degradable cardiovascular stents produced from corrodible metal: results 6-18 months after implantation into New Zealand white rabbits","volume":"86","author":"Peuster","year":"2001","journal-title":"Heart"},{"key":"2026070913270950600_rbag126-B63","doi-asserted-by":"crossref","first-page":"4955","DOI":"10.1016\/j.biomaterials.2006.05.029","article-title":"Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta","volume":"27","author":"Peuster","year":"2006","journal-title":"Biomaterials"},{"key":"2026070913270950600_rbag126-B64","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mser.2014.01.001","article-title":"Biodegradable metals","volume":"77","author":"Zheng","year":"2014","journal-title":"Mater Sci Eng: R: Rep"},{"key":"2026070913270950600_rbag126-B65","doi-asserted-by":"crossref","first-page":"5821","DOI":"10.1016\/j.biomaterials.2004.01.038","article-title":"In vitro degradation of three-dimensional porous poly(d, l-lactide-co-glycolide) scaffolds for tissue engineering","volume":"25","author":"Wu","year":"2004","journal-title":"Biomaterials"}],"container-title":["Regenerative Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rb\/advance-article-pdf\/doi\/10.1093\/rb\/rbag126\/68522845\/rbag126.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rb\/article-pdf\/doi\/10.1093\/rb\/rbag126\/68522845\/rbag126.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rb\/article-pdf\/doi\/10.1093\/rb\/rbag126\/68522845\/rbag126.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T17:27:24Z","timestamp":1783618044000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rb\/article\/doi\/10.1093\/rb\/rbag126\/8707647"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":65,"URL":"https:\/\/doi.org\/10.1093\/rb\/rbag126","relation":{},"ISSN":["2056-3418","2056-3426"],"issn-type":[{"value":"2056-3418","type":"print"},{"value":"2056-3426","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026]]},"published":{"date-parts":[[2026]]},"article-number":"rbag126"}}