{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T16:37:49Z","timestamp":1783615069398,"version":"3.55.0"},"reference-count":22,"publisher":"Oxford University Press (OUP)","issue":"10","license":[{"start":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T00:00:00Z","timestamp":1609977600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"name":"Division of Rheumatology at the University of Alabama at Birmingham"},{"name":"Birmingham VA Medical Center"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,10,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>To examine the accuracy of dual-energy CT (DECT) vs ultrasound or their combination for the diagnosis of gout.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Using prospectively collected data from an outpatient rheumatology clinic at a tertiary-care hospital, we examined the diagnostic accuracy of either modality alone or their combination, by anatomical site (feet\/ankles and\/or knees), for the diagnosis of gout. We used two standards: (i) demonstration of monosodium urate crystals in synovial fluid (gold), and (ii) modified (excluding DECT and ultrasound) 2015 ACR\u2013EULAR gout classification criteria (silver).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Of the 147 patients who provided data, 48 (33%) had synovial fluid analysis performed (38 were monosodium urate-crystal positive) and mean symptom duration was 9.2\u2009years. One hundred (68%) patients met the silver standard. Compared with the gold standard, diagnostic accuracy statistics for feet\/ankles DECT, feet\/ankles ultrasound, knees DECT and knees ultrasound were, respectively: sensitivity: 87%, 84%, 91% and 58%; specificity: 100%, 60%, 87% and 80%; positive predictive value: 100%, 89%, 97% and 92%; negative predictive value: 67%, 50%, 70% and 33%; area under the receiver operating characteristic curve: 0.93, 0.72, 0.89 and 0.66. Combining feet\/ankles DECT with ultrasound or knees DECT with ultrasound led to a numerically higher sensitivity compared with DECT alone, but overall accuracy was lower. Similarly, combining imaging knees to feet\/ankles also yielded a numerically higher sensitivity and negative predictive values compared with feet\/ankles DECT alone, without differences in overall accuracy. Findings were replicated compared with the silver standard, but with lower numbers.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>Feet\/ankles or knees DECT alone had the best overall accuracy for gout diagnosis. The DECT\u2013US combination or multiple joint imaging offered no additional increase in overall diagnostic accuracy.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/rheumatology\/keaa923","type":"journal-article","created":{"date-parts":[[2020,12,18]],"date-time":"2020-12-18T16:56:17Z","timestamp":1608310577000},"page":"4861-4867","source":"Crossref","is-referenced-by-count":28,"title":["Dual-energy computed tomography <i>vs<\/i> ultrasound, alone or combined, for the diagnosis of gout: a prospective study of accuracy"],"prefix":"10.1093","volume":"60","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3485-0006","authenticated-orcid":false,"given":"Jasvinder A","family":"Singh","sequence":"first","affiliation":[{"name":"Medicine Service, Birmingham Veterans Affairs (VA) Medical Center"},{"name":"Department of Medicine at School of Medicine"},{"name":"Division of Epidemiology at School of Public Health, University of Alabama at Birmingham, Birmingham, AL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Fran\u00e7ois","family":"Budzik","sequence":"additional","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology, Lille Catholic Hospitals, University of Lille, Lomme"},{"name":"ULR 4490, Marrow Adiposity and Bone Laboratory (MABLab), University of Lille, Lille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8444-8504","authenticated-orcid":false,"given":"Fabio","family":"Becce","sequence":"additional","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8395-826X","authenticated-orcid":false,"given":"Tristan","family":"Pascart","sequence":"additional","affiliation":[{"name":"ULR 4490, Marrow Adiposity and Bone Laboratory (MABLab), University of Lille, Lille, France"},{"name":"Department of Rheumatology, Lille Catholic Hospitals, University of Lille, Lomme, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2021,1,7]]},"reference":[{"key":"2021100217424433000_keaa923-B1","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1136\/annrheumdis-2019-215315","article-title":"2018 updated European League Against Rheumatism evidence-based recommendations for the diagnosis of gout","volume":"79","author":"Richette","year":"2020","journal-title":"Ann Rheum Dis"},{"key":"2021100217424433000_keaa923-B2","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1136\/annrheumdis-2013-205095","article-title":"Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study","volume":"74","author":"Bongartz","year":"2015","journal-title":"Ann Rheum Dis"},{"key":"2021100217424433000_keaa923-B3","doi-asserted-by":"crossref","first-page":"2117","DOI":"10.1093\/rheumatology\/kez180","article-title":"The diagnostic performance of dual energy CT for diagnosing gout: a systematic literature review and meta-analysis","volume":"58","author":"Gamala","year":"2019","journal-title":"Rheumatology (Oxford)"},{"key":"2021100217424433000_keaa923-B4","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.semarthrit.2017.09.012","article-title":"Diagnostic accuracy of ultrasound in patients with gout: a meta-analysis","volume":"47","author":"Lee","year":"2018","journal-title":"Semin Arthritis Rheum"},{"key":"2021100217424433000_keaa923-B5","doi-asserted-by":"crossref","first-page":"2557","DOI":"10.1002\/art.39254","article-title":"2015 Gout classification criteria: an American College of Rheumatology\/European League Against Rheumatism collaborative initiative","volume":"67","author":"Neogi","year":"2015","journal-title":"Arthritis Rheumatol"},{"key":"2021100217424433000_keaa923-B6","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.1136\/annrheumdis-2014-205431","article-title":"Imaging modalities for the classification of gout: systematic literature review and meta-analysis","volume":"74","author":"Ogdie","year":"2015","journal-title":"Ann Rheum Dis"},{"key":"2021100217424433000_keaa923-B7","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1093\/rheumatology\/ket341","article-title":"Dual-energy computed tomography compared with ultrasound in the diagnosis of gout","volume":"53","author":"Gruber","year":"2014","journal-title":"Rheumatology (Oxford)"},{"key":"2021100217424433000_keaa923-B8","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1007\/s00296-014-2979-1","article-title":"Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout","volume":"34","author":"Huppertz","year":"2014","journal-title":"Rheumatol Int"},{"key":"2021100217424433000_keaa923-B9","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.2214\/AJR.17.19199","article-title":"Acute gouty knee arthritis: ultrasound findings compared with dual-energy CT findings","volume":"210","author":"Strobl","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"2021100217424433000_keaa923-B10","doi-asserted-by":"crossref","first-page":"e12834","DOI":"10.1097\/MD.0000000000012834","article-title":"Detection of uric acid crystal deposition by ultrasonography and dual-energy computed tomography: a cross-sectional study in patients with clinically diagnosed gout","volume":"97","author":"Wang","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"2021100217424433000_keaa923-B11","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1016\/j.acra.2015.08.010","article-title":"Comparison between dual-energy computed tomography and ultrasound in the diagnosis of gout of various joints","volume":"22","author":"Zhu","year":"2015","journal-title":"Acad Radiol"},{"key":"2021100217424433000_keaa923-B12","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1007\/s10067-020-05014-6","article-title":"Diagnostic value of ultrasound versus dual-energy computed tomography in patients with different stages of acute gouty arthritis","volume":"39","author":"Zhang","year":"2020","journal-title":"Clin Rheumatol"},{"key":"2021100217424433000_keaa923-B13","doi-asserted-by":"crossref","first-page":"h5527","DOI":"10.1136\/bmj.h5527","article-title":"STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies","volume":"351","author":"Bossuyt","year":"2015","journal-title":"BMJ"},{"key":"2021100217424433000_keaa923-B14","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1186\/s13075-018-1714-9","article-title":"Monosodium urate burden assessed with dual-energy computed tomography predicts the risk of flares in gout: a 12-month observational study: MSU burden and risk of gout flare","volume":"20","author":"Pascart","year":"2018","journal-title":"Arthritis Res Ther"},{"key":"2021100217424433000_keaa923-B15","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1136\/annrheumdis-2017-212046","article-title":"Presence of monosodium urate crystal deposition by dual-energy CT in patients with gout treated with allopurinol","volume":"77","author":"Dalbeth","year":"2018","journal-title":"Ann Rheum Dis"},{"key":"2021100217424433000_keaa923-B16","doi-asserted-by":"crossref","first-page":"119","DOI":"10.2214\/AJR.14.13901","article-title":"Getting the most from your dual-energy scanner: recognizing, reducing, and eliminating artifacts","volume":"206","author":"Coupal","year":"2016","journal-title":"AJR Am J Roentgenol"},{"key":"2021100217424433000_keaa923-B17","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1186\/s13075-020-02283-z","article-title":"Dual-energy CT in gout patients: do all colour-coded lesions actually represent monosodium urate crystals?","volume":"22","author":"Christiansen","year":"2020","journal-title":"Arthritis Res Ther"},{"key":"2021100217424433000_keaa923-B18","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1186\/s13075-017-1381-2","article-title":"Ultrasonography and dual-energy computed tomography provide different quantification of urate burden in gout: results from a cross-sectional study","volume":"19","author":"Pascart","year":"2017","journal-title":"Arthritis Res Ther"},{"key":"2021100217424433000_keaa923-B19","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1093\/rheumatology\/kev112","article-title":"International Consensus for ultrasound lesions in gout: results of Delphi process and web-reliability exercise","volume":"54","author":"Gutierrez","year":"2015","journal-title":"Rheumatology (Oxford)"},{"key":"2021100217424433000_keaa923-B20","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1093\/rheumatology\/kex164","article-title":"Performance of the 2015 ACR-EULAR classification criteria for gout in a primary care population presenting with monoarthritis","volume":"56","author":"Janssens","year":"2017","journal-title":"Rheumatology (Oxford)"},{"key":"2021100217424433000_keaa923-B21","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/RLI.0000000000000099","article-title":"Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies","volume":"50","author":"Diekhoff","year":"2015","journal-title":"Invest Radiol"},{"key":"2021100217424433000_keaa923-B22","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.2214\/AJR.19.22222","article-title":"Not all green is tophi: the importance of optimizing minimum attenuation and using a tin filter to minimize clumpy artifacts on foot and ankle dual-energy CT","volume":"214","author":"Park","year":"2020","journal-title":"AJR Am J Roentgenol"}],"container-title":["Rheumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rheumatology\/advance-article-pdf\/doi\/10.1093\/rheumatology\/keaa923\/36180184\/keaa923.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/rheumatology\/article-pdf\/60\/10\/4861\/40500334\/keaa923.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/rheumatology\/article-pdf\/60\/10\/4861\/40500334\/keaa923.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,2]],"date-time":"2021-10-02T17:48:23Z","timestamp":1633196903000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rheumatology\/article\/60\/10\/4861\/6067323"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,7]]},"references-count":22,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2021,1,7]]},"published-print":{"date-parts":[[2021,10,2]]}},"URL":"https:\/\/doi.org\/10.1093\/rheumatology\/keaa923","relation":{},"ISSN":["1462-0324","1462-0332"],"issn-type":[{"value":"1462-0324","type":"print"},{"value":"1462-0332","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,10,1]]},"published":{"date-parts":[[2021,1,7]]}}}