{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T06:33:34Z","timestamp":1791959614525,"version":"4.3.4"},"reference-count":28,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2020,3,20]],"date-time":"2020-03-20T00:00:00Z","timestamp":1584662400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,7,13]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Cytogenetic biodosimetry is a well-known method for quantifying the absorbed dose based on measuring biological radiation effects. To correlate the induced chromosomal abberrations with the absorbed dose of the individuals, a reliable dose\u2013response calibration curve should be established. This study aimed to use frequencies and distributions of radiation-induced dicentric chromosome aberrations to develop a standard dose\u2013response calibration curve. Peripheral blood samples taken from six male donors irradiated by an X-ray generator up to 4\u00a0Gy were studied. Three different blood samples were irradiated by known doses, then scored blindly for verification of the proposed calibration curve. Dose estimation was also carried out for three real overexposed cases. The results showed good accordance with the other published curves. The constructed dose\u2013response curve provides a reliable tool for biological dosimetry in accidental or occupational radiation exposures.<\/jats:p>","DOI":"10.1093\/rpd\/ncaa031","type":"journal-article","created":{"date-parts":[[2020,3,7]],"date-time":"2020-03-07T12:26:34Z","timestamp":1583583994000},"page":"198-204","source":"Crossref","is-referenced-by-count":7,"title":["CONSTRUCTION AND VALIDATION OF IN VITRO DOSE\u2013RESPONSE CALIBRATION CURVE USING DICENTRIC CHROMOSOME ABERRATION"],"prefix":"10.1093","volume":"189","author":[{"given":"Ehsan","family":"Mirrezaei","sequence":"first","affiliation":[{"name":"Department of Energy Engineering and Physics, Amirkabir University of Technology (Tehran Polytechnic), Tehran 11365-3486, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saeed","family":"Setayeshi","sequence":"first","affiliation":[{"name":"Department of Energy Engineering and Physics, Amirkabir University of Technology (Tehran Polytechnic), Tehran 11365-3486, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farideh","family":"Zakeri","sequence":"first","affiliation":[{"name":"Nuclear Science and Technology Research Institute, Tehran 14155-1339, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samaneh","family":"Baradaran","sequence":"first","affiliation":[{"name":"Nuclear Science and Technology Research Institute, Tehran 14155-1339, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,3,20]]},"reference":[{"key":"2020071309123570900_ref1","year":"2014-02-01"},{"key":"2020071309123570900_ref2","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1007\/s00411-010-0311-3","article-title":"Current status of biodosimetry based on standard cytogenetic methods","volume":"49","author":"De Lemos Pinto","year":"2010","journal-title":"Radiat. Environ. Biophy."},{"key":"2020071309123570900_ref3","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1093\/rpd\/nch349","article-title":"International intercomparison for criticality dosimetry: the case of biological dosimetry","volume":"110","author":"Roy","year":"2004","journal-title":"Radiat. Prot. Dosim."},{"key":"2020071309123570900_ref4","first-page":"247","volume-title":"Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies, Man. Ser.,","author":"IAEA","year":"2011"},{"key":"2020071309123570900_ref5","first-page":"290","article-title":"Dose estimation software for radiation biodosimetry","volume-title":"Health Phys.","author":"Ainsbury","year":"2010"},{"key":"2020071309123570900_ref6","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1667\/RR2321.1","article-title":"Biological Dosimetry by the triage dicentric chromosome assay: potential implications for treatment of acute radiation syndrome in radiological mass casualties radiation research","volume":"175","author":"Romm","year":"2011","journal-title":"Radiat. Res."},{"key":"2020071309123570900_ref7","first-page":"75","article-title":"The relationship between chromosome aberrations and low LET radiation dose to human lymphocytes","volume":"28","author":"Lloyd","year":"1975","journal-title":"Int. J. Radiat. Biol."},{"key":"2020071309123570900_ref8","first-page":"251","article-title":"Cytogenetic damage analysed by the dicentric assay","volume-title":"Annali dell\u2019Istituto Superiore di Sanita","author":"Romm","year":"2009"},{"key":"2020071309123570900_ref9","first-page":"252","article-title":"The use of the dicentric assay for biological dosimetry for radiation accidents in Bulgaria","volume-title":"Health Phys.","author":"Hadjidekova","year":"2010"},{"key":"2020071309123570900_ref10","first-page":"55","article-title":"Persistence of chromosome aberrations in an accidentally irradiated subject","volume-title":"Radiat. Prot. Dosim.","author":"L\u00e9onard","year":"1988"},{"key":"2020071309123570900_ref11","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/00004032-199101000-00010","article-title":"The fate of chromosomal aberrations in 137cs-exposed individuals in the goiania radiation accident","volume":"60","author":"Ramalho","year":"1991","journal-title":"Health Phys."},{"key":"2020071309123570900_ref12","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1667\/RR2097.1","article-title":"The dose response of chromosome aberrations in human lymphocytes induced in vitro by very low-dose \u03b3 rays","volume":"175","author":"Iwasaki","year":"2011","journal-title":"Radiat. Res."},{"key":"2020071309123570900_ref13","first-page":"168","article-title":"Cytogenetic biodosimetry: what it is and how we do it","volume-title":"Hong Kong Med J.","author":"Wong","year":"2013"},{"key":"2020071309123570900_ref14","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.ejrad.2008.10.015","article-title":"A cytogenetic approach to the effects of low levels of ionizing radiations on occupationally exposed individuals","volume":"73","author":"Zakeri","year":"2010","journal-title":"Eur. J. Radiol."},{"key":"2020071309123570900_ref15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mrgentox.2004.04.005","article-title":"Cytogenetic monitoring of personnel working in angiocardiography laboratories in Iran hospitals","volume":"562","author":"Zakeri","year":"2004","journal-title":"Mut. Res. Genet. Toxicol. Environ. Mutagen."},{"key":"2020071309123570900_ref16","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1093\/rpd\/ncm137","article-title":"Cabas: a freely available pc program for fitting calibration curves in chromosome aberration dosimetry","volume":"124","author":"Deperas-kaminska","year":"2007","journal-title":"Radiat. Prot. Dosim."},{"key":"2020071309123570900_ref17","first-page":"307","article-title":"Biodosimetric tools for a fast triage of people accidentally exposed to ionising radiation: statistical and computational aspects","volume":"45","author":"Ainsbury","year":"2009","journal-title":"Ann Ist Super Sanita."},{"key":"2020071309123570900_ref18","first-page":"402","article-title":"BioDoser: improved dose-estimation software for biological radiation dosimetry","volume-title":"Comput Methods Programs Biomed.","author":"Wang","year":"2012"},{"key":"2020071309123570900_ref19","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1007\/BF01323216","article-title":"Radiation induced chromosome aberrations and the poisson distribution","volume":"16","author":"Edwards","year":"1979","journal-title":"Radiat. Environ. Biophy."},{"key":"2020071309123570900_ref20","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s00411-015-0624-3","article-title":"The cytokinesis-blocked micronucleus assay: dose response calibration curve, background frequency in the population and dose estimation","volume":"55","author":"Rastkhah","year":"2016","journal-title":"Radiat. Environ. Biophys."},{"key":"2020071309123570900_ref21","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1093\/oxfordjournals.rpd.a080358","article-title":"Dose assessments by cytogenetic analysis in the Goiania (Brazil) radiation accident","volume":"25","author":"Ramalho","year":"1988","journal-title":"Radiat. Prot. Dosim."},{"key":"2020071309123570900_ref22","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/0027-5107(94)00150-4","article-title":"Establishment and validation of a dose-effect curve for \u03b3-rays by cytogenetic analysis","volume":"326","author":"Barquinero","year":"1995","journal-title":"Mut. Res."},{"key":"2020071309123570900_ref23","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/HP.0b013e3181b35a53","article-title":"Establishment of an X-ray standard calibration curve by conventional dicentric analysis as prerequisite for accurate radiation dose assessment","volume":"98","author":"Beinke","year":"2010","journal-title":"Health Phys."},{"key":"2020071309123570900_ref24","volume-title":"AFRRI\u2019s Gamma-Ray, X-Ray, and Fission-Neutron Calibration Curves for the Lymphocyte Dicentric Assay: Application of a Metaphase Finder System","author":"Prasanna","year":"2002"},{"key":"2020071309123570900_ref25","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/S1383-5718(02)00067-0","article-title":"Chromosome aberrations induced in human lymphocytes by in vitro and in vivo X-rays","volume":"517","author":"Schr\u00f6der","year":"2002","journal-title":"Mut. Res. Genet. Toxicol. Environ. Mutagen."},{"key":"2020071309123570900_ref26","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1093\/oxfordjournals.rpd.a079681","article-title":"Chromosome aberrations induced in human lymphocytes by in vitro acute X and gamma radiation","volume":"15","author":"Lloyd","year":"1986","journal-title":"Radiat. Prot. Dosim."},{"key":"2020071309123570900_ref27","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1007\/BF01407604","article-title":"The effect of 220 kVp X-rays with different spectra on the dose response of chromosome aberrations in human lymphocytes","volume":"23","author":"Schmid","year":"1984","journal-title":"Radiat. Environ. Biophys."},{"key":"2020071309123570900_ref28","first-page":"563","article-title":"Biological dosimetry following X-ray irradiation","volume":"30","author":"Co\u015fkun","year":"2000","journal-title":"Turk. J. Med. Sci."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/189\/2\/198\/33490301\/ncaa031.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/189\/2\/198\/33490301\/ncaa031.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,13]],"date-time":"2020-07-13T13:13:13Z","timestamp":1594645993000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/189\/2\/198\/5810362"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,20]]},"references-count":28,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020,3,20]]},"published-print":{"date-parts":[[2020,7,13]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaa031","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,4]]},"published":{"date-parts":[[2020,3,20]]}}}