{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T23:21:30Z","timestamp":1783984890626,"version":"3.55.0"},"reference-count":22,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T00:00:00Z","timestamp":1590969600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,8,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>According to the ALARA principle, exposure to radiation should be reduced as low as reasonably achievable. This principle is very important in nuclear medicine (NM), and different investigations have been performed by establishing protocols and standards for staff protection. This study aims to measure the operational quantities, personal dose equivalent, Hp (10), Hp (0.07) and Hp (3) for NM staff in Shiraz hospitals, and comparison with dose limits. Two types of dosimeters, TLD-100 and GR-200, were used in this study. In the first step, the calibration of dosimeters was performed using different phantoms. Then, a group of dosimeters was prepared and used for 1 month on the heads, wrists and chests of the staff for measurement of Hp (3), Hp (0.07) and Hp (10), respectively. The obtained values of Hp (10) were compared with the results of their personal dosimetry, film badge. The results of this study show good consistency in the measurements using the two dosimeters.<\/jats:p>","DOI":"10.1093\/rpd\/ncaa083","type":"journal-article","created":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T11:45:28Z","timestamp":1590147928000},"page":"119-124","source":"Crossref","is-referenced-by-count":8,"title":["MEASUREMENT OF OPERATIONAL DOSIMETRY QUANTITIES FOR NUCLEAR MEDICINE STAFF"],"prefix":"10.1093","volume":"190","author":[{"given":"Nahid","family":"Dehghan","sequence":"first","affiliation":[{"name":"Nuclear Engineering Department, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sedigheh","family":"Sina","sequence":"additional","affiliation":[{"name":"Nuclear Engineering Department, Shiraz University, Shiraz, Iran"},{"name":"Radiation Research Center, Shiraz University, Shiraz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,6,29]]},"reference":[{"key":"2020082818220505400_ref1","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/978-3-642-31167-3_7","article-title":"Occupational exposure: with special reference to skin doses in hands and fingers","author":"Carnicer","year":"2013","journal-title":"Radiat. Prot. Nucl. Med."},{"key":"2020082818220505400_ref2","volume-title":"For occupational radiation protection of the new dose limit for the lens of the eye\u2014interim guidance for use and comment. IAEA-Tecdoc-1731","author":"IAEA","year":"2013"},{"issue":"4","key":"2020082818220505400_ref3","first-page":"554","article-title":"IAEA Tec Doc-1731 \u2018implications for occupational radiation protection of the new dose limit for the lens of the eye","volume":"171","author":"Carinou","year":"2016","journal-title":"Radiat. Prot. Dosim."},{"issue":"11","key":"2020082818220505400_ref4","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/j.radmeas.2011.07.029","article-title":"Investigation of radiation exposure of medical staff: measurements supported by simulations with an articulated hand phantom","volume":"46","author":"Becker","year":"2011","journal-title":"Radiat. Meas."},{"issue":"5","key":"2020082818220505400_ref5","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1111\/j.1740-8261.2012.01958.x","article-title":"Occupational per-patient radiation dose from a conservative protocol for veterinary 18f-fluorodeoxyglucose positron emission tomography","volume":"53","author":"Martinez","year":"2012","journal-title":"Vet. Radiol. Ultrasound"},{"key":"2020082818220505400_ref6","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.radphyschem.2017.02.048","article-title":"Occupational radiation exposure in nuclear medicine department in Kuwait","volume":"140","author":"Alnaaimi","year":"2017","journal-title":"Radiat. Phys. Chem."},{"key":"2020082818220505400_ref7","article-title":"General principles for the radiation protection of workers.","volume":"27","author":"ICRP","year":"1997","journal-title":"Ann. ICRP"},{"key":"2020082818220505400_ref8","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1177\/0146645315624341","article-title":"Operational quantities and new approach by ICRU","volume":"45","year":"2016","journal-title":"Ann. ICRP"},{"key":"2020082818220505400_ref9","article-title":"The 2007 Recommendations of the International Commission on Radiological Protection","volume":"37","author":"ICRP.","year":"2007","journal-title":"ICRP publication 103 Ann. ICRP"},{"key":"2020082818220505400_ref10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context","volume":"41","author":"Stewart","year":"(2012)","journal-title":"Ann. ICRP"},{"key":"2020082818220505400_ref11","first-page":"iii","article-title":"Protecting people against radiation exposure in the event of a radiological attack","volume":"35","author":"Mettler","journal-title":"Ann. ICRP"},{"issue":"11","key":"2020082818220505400_ref12","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1016\/j.radmeas.2011.07.038","article-title":"Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign","volume":"46","author":"Nikodemov\u00e1","year":"2011","journal-title":"Radiat. Meas."},{"key":"2020082818220505400_ref13","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1007\/978-3-642-03902-7_133","article-title":"The ORAMED project: optimisation of radiation protection for medical staff","author":"Vanhavere","year":"2009","journal-title":"IFMBE Proc."},{"key":"2020082818220505400_ref14","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1093\/rpd\/ncz046","article-title":"Occupational radiation dose to nuclear medicine staff due to Tc 99m, F 18-FDG PET, and therapeutic I-131, based examinations","volume":"186","author":"Fathy","year":"2019","journal-title":"Radiat. Prot. Dosim."},{"issue":"3","key":"2020082818220505400_ref15","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1504\/IJLR.2009.028887","article-title":"The evaluation of the dose equivalent to the people accompanying patients in diagnostic radiology using the MCNP4C Monte Carlo code and TL dosimetry","volume":"6","author":"Mehdizadeh","year":"2009","journal-title":"Int. J. Low Rad."},{"issue":"3","key":"2020082818220505400_ref16","first-page":"169","article-title":"Finger doses for staff handling radiopharmaceuticals in nuclear medicine","volume":"34","author":"Pant","year":"2006","journal-title":"J. Nucl. Med. Technol."},{"issue":"4","key":"2020082818220505400_ref17","first-page":"119","article-title":"Investigation of the entrance surface dose and dose to different organs in lumbar spine imaging","volume":"4","author":"Sina","year":"2014","journal-title":"J. Biomed. Phy. Eng."},{"issue":"2","key":"2020082818220505400_ref18","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1093\/rpd\/ncw300","article-title":"Developing an optimum protocol for thermoluminescence dosimetry with GR-200 chips using taguchi method","volume":"175","author":"Sadeghi","year":"2017","journal-title":"Radiat. Prot. Dosim."},{"key":"2020082818220505400_ref19","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.radphyschem.2019.03.004","article-title":"Occupational exposure in nuclear medicine and interventional cardiology departments in Sudan: Are they following radiation protection standards?","volume":"160","author":"Suliman","year":"2019","journal-title":"Radiat. Phys.Chem."},{"key":"2020082818220505400_ref20","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1159\/000357123","article-title":"Occupational radiation exposure among the staff of departments of nuclear medicine and diagnostic radiology in Kuwait","volume":"23","author":"Al-Abdulsalam","year":"2014","journal-title":"Med. Princ. Pract."},{"key":"2020082818220505400_ref21","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1093\/rpd\/ncl564","article-title":"Occupational exposure in nuclear medicine in Portugal in the 1999-2003 period","volume":"125","author":"Martins","year":"2007","journal-title":"Radiat. Prot. Dosim."},{"key":"2020082818220505400_ref22","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1088\/1361-6498\/aabef5","article-title":"Is eye lens dosimetry needed in nuclear medicine","volume":"38","author":"Wrzesie\u0144","year":"2018","journal-title":"J. Radiat. Prot. Res."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/190\/2\/119\/33693315\/ncaa083.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/190\/2\/119\/33693315\/ncaa083.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,8,31]],"date-time":"2020-08-31T17:02:19Z","timestamp":1598893339000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/190\/2\/119\/5864124"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":22,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020,6,29]]},"published-print":{"date-parts":[[2020,8,28]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaa083","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,6]]},"published":{"date-parts":[[2020,6]]}}}