{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:57:10Z","timestamp":1740139030205,"version":"3.37.3"},"reference-count":36,"publisher":"Oxford University Press (OUP)","issue":"3-4","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,12,30]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The goal of the present study was to estimate the radiation dose for a group of 45 Kawasaki disease (KD) patients undergoing fluoroscopically guided cardiac catheterization.<\/jats:p>\n               <jats:p>The sample of procedures corresponds to a single hospital and was collected in 10\u00a0years. Anthropometric characteristics and the quantities of air kerma-area product (PKA) among others were recorded for each procedure. Monte Carlo PCXMC 2.0 software was used to estimate organ and effective doses.<\/jats:p>\n               <jats:p>The PKA value of 7.2\u00a0Gy\u00a0cm2 was proposed as the local Diagnostic Reference Level for KD. For organ absorbed doses, median values for thyroid, heart, lungs, esophagus, skin, active bone and breast were 1.2; 2.2; 4.6; 2.7; 1.1; 1.2 and 2.7\u00a0mGy, respectively. For effective dose, the mean value was 2.7\u00a0\u00b1\u00a02.5\u00a0mSv.<\/jats:p>\n               <jats:p>This paper presents the first patient dose values for the KD using catheterization techniques, in Latin America and the Caribbean Region.<\/jats:p>","DOI":"10.1093\/rpd\/ncab182","type":"journal-article","created":{"date-parts":[[2021,12,31]],"date-time":"2021-12-31T20:10:59Z","timestamp":1640981459000},"page":"230-236","source":"Crossref","is-referenced-by-count":0,"title":["RADIATION DOSE FOR PATIENTS WITH KAWASAKI DISEASE UNDERGOING FLUOROSCOPICALLY GUIDED CARDIAC CATHETERIZATION"],"prefix":"10.1093","volume":"197","author":[{"given":"Patricia","family":"Miranda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eliseo","family":"Vano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Ubeda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ximena","family":"Figueroa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulina","family":"Doggenweiller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9942-1478","authenticated-orcid":false,"given":"Marcus","family":"Oliveira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dandaro","family":"Dalmazzo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2022,1,4]]},"reference":[{"issue":"14","key":"2022020205052795300_ref1","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.1016\/j.jacc.2015.12.073","article-title":"Kawasaki disease","volume":"67","author":"Newburger","year":"2016","journal-title":"J. Am. Coll. Cardiol."},{"key":"2022020205052795300_ref2","doi-asserted-by":"crossref","first-page":"e927","DOI":"10.1161\/CIR.0000000000000484","article-title":"Diagnosis, treatment, and long-term management of Kawasaki disease: a scientific statement for health professionals from the American Heart Association","volume":"135","author":"McCrindle","year":"2017","journal-title":"Circulation"},{"issue":"6","key":"2022020205052795300_ref3","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1016\/S0022-3476(75)80220-4","article-title":"Coronary aneurysms in infants and young children with acute febrile mucocutaneous lymph node syndrome","volume":"86","author":"Kato","year":"1975","journal-title":"J. Pediatr."},{"issue":"6","key":"2022020205052795300_ref4","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0038998","article-title":"Three linked vasculopathic processes characterize Kawasaki disease: a light and transmission electron microscopic study","volume":"7","author":"Orenstein","year":"2012","journal-title":"PLoS One"},{"issue":"1","key":"2022020205052795300_ref5","doi-asserted-by":"crossref","first-page":"12","DOI":"10.4067\/S0716-10182016000100002","article-title":"Geographic distribution of Kawasaki disease throughout Chile","volume":"33","author":"Hoyos-Bachiloglu","year":"2016","journal-title":"Rev. Chil. Infectol."},{"issue":"17","key":"2022020205052795300_ref6","doi-asserted-by":"crossref","first-page":"2747","DOI":"10.1161\/01.CIR.0000145143.19711.78","article-title":"Diagnosis, treatment, and long-term management of Kawasaki disease: a statement for health professionals from the committee on rheumatic fever, endocarditis and Kawasaki disease, council on cardiovascular disease in the young, American Heart Association","volume":"110","author":"Newburger","year":"2004","journal-title":"Circulation"},{"issue":"12","key":"2022020205052795300_ref7","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.1017\/S1047951119002506","article-title":"Estimating radiation exposure during paediatric cardiac catheterisation: a potential for radiation reduction with air gap technique","volume":"29","author":"Chamberlain","year":"2019","journal-title":"Cardiol. Young"},{"issue":"4","key":"2022020205052795300_ref8","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.jpeds.2013.10.074","article-title":"Cumulative exposure to medical radiation for children requiring surgery for congenital heart disease","volume":"164","author":"Glatz","year":"2014","journal-title":"J. Pediatr."},{"issue":"2","key":"2022020205052795300_ref9","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1161\/CIRCULATIONAHA.113.005425","article-title":"Cumulative radiation exposure and cancer risk estimation in children with heart disease","volume":"130","author":"Johnson","year":"2014","journal-title":"Circulation"},{"key":"2022020205052795300_ref10","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.ejmp.2017.07.015","article-title":"Organ and effective doses from paediatric interventional cardiology procedures in Chile","volume":"40","author":"Ubeda","year":"2017","journal-title":"Phys. Med."},{"key":"2022020205052795300_ref11","first-page":"1","article-title":"The 2007 recommendations of the international commission on radiological protection. ICRP publication 103","volume":"37","author":"International Commission on Radiological Protection","year":"2007","journal-title":"Ann. ICRP"},{"issue":"Suppl 1(Suppl 1)","key":"2022020205052795300_ref12","doi-asserted-by":"crossref","first-page":"S4","DOI":"10.1007\/s00247-008-1026-3","article-title":"Children\u2019s exposure to diagnostic medical radiation and cancer risk: epidemiologic and dosimetric considerations","volume":"39","author":"Linet","year":"2009","journal-title":"Pediatr. Radiol."},{"key":"2022020205052795300_ref13","first-page":"1","volume-title":"ICRU Report 74. J ICRU","author":"International Commission on Radiation Units and Measurements (ICRU)","year":"2005"},{"volume-title":"Medical Electrical Equipment\u2013Part 2\u201343: Particular Requirements for the Basic Safety and Essential Performance of X-Ray Equipment for Interventional Procedures, 2.0. IEC 60601\u201360602\u201343","year":"2010","author":"International Electrotechnical Commission (IEC)","key":"2022020205052795300_ref14"},{"key":"2022020205052795300_ref15","first-page":"50","article-title":"Campa\u00f1a internacional de protecci\u00f3n radiol\u00f3gica Para Am\u00e9rica Latina y el Caribe en procedimientos intervencionistas","volume":"2","author":"Ortiz","year":"2016","journal-title":"Rev. Cienc. Salud Med."},{"issue":"1","key":"2022020205052795300_ref16","first-page":"105","article-title":"Proyecto de cooperaci\u00f3n t\u00e9cnica RLA9075.Una herramienta para mejorar la protecci\u00f3n radiol\u00f3gica en la regi\u00f3n de Am\u00e9rica Latina","volume":"2","author":"S\u00e1nchez","year":"2016","journal-title":"Rev. Cienc. Salud Med."},{"issue":"15","key":"2022020205052795300_ref17","doi-asserted-by":"crossref","first-page":"4049","DOI":"10.1088\/0031-9155\/53\/15\/003","article-title":"Radiation dose and image quality for paediatric interventional cardiology","volume":"53","author":"Vano","year":"2008","journal-title":"Phys. Med. Biol."},{"issue":"3","key":"2022020205052795300_ref18","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1093\/rpd\/ncq463","article-title":"Radiation dose and image quality for paediatric interventional cardiology systems. A national survey in Chile","volume":"147","author":"Ubeda","year":"2011","journal-title":"Radiat. Prot. Dosim."},{"issue":"1\u20134","key":"2022020205052795300_ref19","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1093\/rpd\/ncv045","article-title":"Entrance surface air kerma in X-ray systems for paediatric interventional cardiology: a national survey","volume":"165","author":"Ubeda","year":"2015","journal-title":"Radiat. Prot. Dosim."},{"issue":"1","key":"2022020205052795300_ref20","doi-asserted-by":"crossref","first-page":"72","DOI":"10.4067\/S0717-95022017000100013","article-title":"Checklist for reporting results using observational descriptive studies as research designs: the MInCir initiative","volume":"35","author":"Manterola","year":"2017","journal-title":"Int. J. Morphol."},{"key":"2022020205052795300_ref21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"Diagnostic reference levels in medical imaging. Annals of the ICRP 135","volume":"46","author":"International Commission on Radiological Protection","year":"2017","journal-title":"Ann. ICRP"},{"key":"2022020205052795300_ref22","volume-title":"PCXMC: A Monte Carlo Program for Calculating Patient Doses in medical X-ray Examinations","author":"Tapiovaara","year":"2008","edition":"second"},{"volume-title":"SPSS statistics","author":"IBM","key":"2022020205052795300_ref23"},{"issue":"2","key":"2022020205052795300_ref24","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1118\/1.4905116","article-title":"Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values","volume":"42","author":"Ubeda","year":"2015","journal-title":"Med. Phys."},{"key":"2022020205052795300_ref25","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.ejmp.2019.03.020","article-title":"Organ and effective doses detriment to paediatric patients undergoing multiple interventional cardiology procedures","volume":"60","author":"Ubeda","year":"2019","journal-title":"Phys. Med."},{"volume-title":"Technical Reports Series No. 457 Dosimetry in Diagnostic Radiology: An Internacional Code of Practice","year":"2007","author":"International Atomic Energy Agency","key":"2022020205052795300_ref26"},{"key":"2022020205052795300_ref27","first-page":"7","volume-title":"ICRP Publication 85","author":"International Commission on Radiological Protection (ICRP)","year":"2000"},{"volume-title":"Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs\u2013Threshold Doses for Tissue Reactions in a Radiation Protection Context","year":"2012","author":"International Commission on Radiological Protection","key":"2022020205052795300_ref28"},{"key":"2022020205052795300_ref29","doi-asserted-by":"crossref","first-page":"R131","DOI":"10.1088\/0952-4746\/36\/4\/R131","article-title":"Patient radiation doses in paediatric interventional cardiology procedures: a review","volume":"36","author":"Harbron","year":"2016","journal-title":"J. Radiol. Prot."},{"key":"2022020205052795300_ref30","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1088\/0952-4746\/29\/2\/011","article-title":"Estimation of children\u2019s radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation","volume":"29","author":"Yakoumakis","year":"2009","journal-title":"J. Radiol. Prot."},{"key":"2022020205052795300_ref31","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s00246-011-0064-z","article-title":"Radiation exposure in children during the current era of pediatric cardiac intervention","volume":"33","author":"El Sayed","year":"2012","journal-title":"Pediatr. Cardiol."},{"key":"2022020205052795300_ref32","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1007\/s00246-014-0895-5","article-title":"Local reference levels and organ doses from pediatric cardiac interventional procedures","volume":"35","author":"Barnaoui","year":"2014","journal-title":"Pediatr. Cardiol."},{"key":"2022020205052795300_ref33","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1007\/s00246-015-1297-z","article-title":"Measurements of coronary artery aneurysms due to Kawasaki disease by dual source computed tomography (DSCT)","volume":"37","author":"Tsujii","year":"2015","journal-title":"Pediatr. Cardiol."},{"key":"2022020205052795300_ref34","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1258\/ar.2012.120484","article-title":"Coronary artery abnormalities in Kawasaki disease: comparison between CT and MR coronary","volume":"54","author":"Kim","year":"2013","journal-title":"Acta Radiol."},{"key":"2022020205052795300_ref35","doi-asserted-by":"crossref","first-page":"e1190","DOI":"10.1259\/bjr\/18174517","article-title":"Application of prospective ECG-triggered dual-source CT coronary angiography for infants and children with coronary artery aneurysms dueto Kawasaki disease","volume":"85","author":"Duan","year":"2012","journal-title":"Br. J. Radiol."},{"key":"2022020205052795300_ref36","article-title":"Infant cardiac CT angiography with 64-slice and 256-slice CT: comparison of radiation dose and image quality using a pediatric phantom","volume":"7","author":"Lee","year":"2012","journal-title":"PLoS One"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/197\/3-4\/230\/42356501\/ncab182.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/197\/3-4\/230\/42356501\/ncab182.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T05:12:05Z","timestamp":1643778725000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/197\/3-4\/230\/6494711"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":36,"journal-issue":{"issue":"3-4","published-online":{"date-parts":[[2022,1,4]]},"published-print":{"date-parts":[[2021,12,30]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncab182","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2021,12]]},"published":{"date-parts":[[2021,12]]}}}