{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T17:21:03Z","timestamp":1769102463644,"version":"3.49.0"},"reference-count":13,"publisher":"Oxford University Press (OUP)","issue":"15-16","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,10,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>CR-39 (PADC) nuclear track detectors are among the most widespread devices used for personal neutron dosimetry; however, some issues related to the variable material quality of the CR-39 polymer hinder the performance of CR-39-based dosemeters. For this reason, the Working Group 2 (WG2) of the European Radiation Dosimetry Group (EURADOS) has recently launched the CR-39 Quality task, a project aimed at improving and harmonising personal neutron dosimetry with CR-39 in Europe. Whitin this task, a close collaboration among researchers, individual monitoring services and dosemeter grade CR-39 manufacturers is achieved, thus facilitating the direct dialog between producer and consumer to reach an optimised material for personal neutron dosimetry applications.<\/jats:p>","DOI":"10.1093\/rpd\/ncad068","type":"journal-article","created":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T22:59:59Z","timestamp":1697065199000},"page":"1867-1871","source":"Crossref","is-referenced-by-count":8,"title":["The EURADOS <i>CR-39 Quality<\/i> task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)"],"prefix":"10.1093","volume":"199","author":[{"given":"Matteo","family":"Bolzonella","sequence":"first","affiliation":[{"name":"Politecnico di Milano Department of Energy, , Via Lambruschini 4, 20156 Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Caresana","sequence":"additional","affiliation":[{"name":"Politecnico di Milano Department of Energy, , Via Lambruschini 4, 20156 Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip J","family":"Gilvin","sequence":"additional","affiliation":[{"name":"UK Health Security Agency, Chilton Personal Dosimetry Service, , Didcot, Oxon OX11 0RQ, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eduardo G","family":"Yukihara","sequence":"additional","affiliation":[{"name":"Paul Scherrer Institute Department of Radiation Safety and Security, , Forschungsstrasse 111, 5232 Villigen PSI, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie-Anne","family":"Chevallier","sequence":"additional","affiliation":[{"name":"Institut de Radioprotection et de S\u00fbret\u00e9 Nucl\u00e9aire (IRSN) Dosimetry Research Department, , BP 17, 31 avenue de la Division Leclerc, 92260 Fontenay-aux-Roses, France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2023,10,11]]},"reference":[{"key":"2023101114212634700_ref1","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/S0146-6453(96)90003-2","article-title":"Conversion coefficients for use in radiological protection against external radiation, ICRP publication 74","volume":"26","author":"International Commission on Radiological Protection (ICRP)","year":"1996","journal-title":"Ann. ICRP"},{"key":"2023101114212634700_ref2","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1093\/rpd\/nct295","article-title":"EURADOS IC2012N: EURADOS 2012 intercomparison for whole-body neutron dosimetry","volume":"161","author":"Fantuzzi","year":"2014","journal-title":"Radiat. Prot. Dosim."},{"key":"2023101114212634700_ref3","doi-asserted-by":"crossref","first-page":"106364","DOI":"10.1016\/j.radmeas.2020.106364","article-title":"Results of the EURADOS 2017 intercomparison for whole body neutron dosemeters (IC2017n)","volume":"135","author":"Mayer","year":"2020","journal-title":"Radiat. Meas."},{"key":"2023101114212634700_ref4","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/0029-554X(78)90989-8","article-title":"A nuclear-track-recording polymer of unique sensitivity and resolution","volume":"153","author":"Cartwright","year":"1978","journal-title":"Nucl. Instrum. Methods"},{"key":"2023101114212634700_ref5","doi-asserted-by":"crossref","first-page":"106456","DOI":"10.1016\/j.radmeas.2020.106456","article-title":"A self-consistent FLUKA algorithm for studying the response of passive dosimeters based on CR-39 track detectors in fast neutron fields","volume":"138","author":"Bolzonella","year":"2020","journal-title":"Radiat. Meas."},{"key":"2023101114212634700_ref6","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.mser.2004.07.003","article-title":"Formation and growth of tracks in nuclear track materials","volume":"46","author":"Nikezic","year":"2004","journal-title":"Mater. Sci. Eng. A"},{"key":"2023101114212634700_ref7","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1093\/oxfordjournals.rpd.a032322","article-title":"The contribution of Eurados and Cendos to track etch neutron dosimetry: the current status in Europe","volume":"77","author":"Harvey","year":"1998","journal-title":"Radiat. Prot. Dosim."},{"key":"2023101114212634700_ref8","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1093\/rpd\/ncx193","article-title":"Comparison of PADC neutron detectors from different suppliers","volume":"180","author":"Caresana","year":"2018","journal-title":"Radiat. Prot. Dosim."},{"key":"2023101114212634700_ref9","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1093\/oxfordjournals.rpd.a006052","article-title":"CR-39 acceptance test and optimisation for fast neutron dosimetry applications","volume":"101","author":"Fantuzzi","year":"2002","journal-title":"Radiat. Prot. Dosim."},{"key":"2023101114212634700_ref10","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.radmeas.2010.01.030","article-title":"About ageing and fading of Cr-39 PADC track detectors used as air radon concentration measurement devices","volume":"45","author":"Caresana","year":"2010","journal-title":"Radiat. Meas."},{"key":"2023101114212634700_ref11","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1093\/rpd\/ncab063","article-title":"EURADOS strategic research agenda 2020: vision for the dosimetry of ionising radiation","volume":"194","author":"Harrison","year":"2021","journal-title":"Radiat. Prot. Dosim."},{"key":"2023101114212634700_ref12","author":"Task official website"},{"key":"2023101114212634700_ref13","doi-asserted-by":"crossref","first-page":"100114","DOI":"10.1016\/j.physo.2022.100114","article-title":"Neutron personal dosimetry using polyallyl diglycol carbonate (PADC): current status, best practices and proposed research","volume":"12","author":"Bolzonella","year":"2022","journal-title":"Phys. Open"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/199\/15-16\/1867\/52008612\/ncad068.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/199\/15-16\/1867\/52008612\/ncad068.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T23:00:07Z","timestamp":1697065207000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/199\/15-16\/1867\/7306595"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":13,"journal-issue":{"issue":"15-16","published-online":{"date-parts":[[2023,10,11]]},"published-print":{"date-parts":[[2023,10,11]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncad068","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,10]]},"published":{"date-parts":[[2023,10]]}}}