{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:57:44Z","timestamp":1740139064492,"version":"3.37.3"},"reference-count":12,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T00:00:00Z","timestamp":1699488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,12,29]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study aimed to obtain reference dosimetry practices for flattened photon and electron beams. A questionnaire survey on these practices was sent to 37 facilities that performed radiotherapy using these beams in Fukui, Ishikawa, Niigata and Toyama, Japan. The survey comprised equipment (dosemeters, water phantoms, thermometers, barometers and hygrometers) and procedures for reference dosimetry (water used as the phantoms, verification of chamber placement, periodic checks of ion recombination- and polarity-corrections, pre-irradiation and relative humidity monitoring). Responses were received from 19 institutions. In the 19 institutions, a reference-class dosemeter was used for the reference dosimetry. In 6 of the 19 institutions, a 10-year-old or older dosemeter was used. Any barometers, thermometers and hygrometers were not recalibrated. Dosimetry equipment necessitates regular maintenance. Moreover, it is necessary to have a backup dosimetry system in clinics to account for potential malfunctions or instances when the primary system is sent for calibration.<\/jats:p>","DOI":"10.1093\/rpd\/ncad260","type":"journal-article","created":{"date-parts":[[2023,11,11]],"date-time":"2023-11-11T19:23:30Z","timestamp":1699730610000},"page":"106-112","source":"Crossref","is-referenced-by-count":1,"title":["Survey on reference dosimetry practice in Hokuriku region, Japan"],"prefix":"10.1093","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-3738-1325","authenticated-orcid":false,"given":"Naoki","family":"Kinoshita","sequence":"first","affiliation":[{"name":"Department of Radiology, Faculty of Medical Sciences, University of Fukui , 23-3, Matsuoka-shimoaizuki, Eiheiji, Yoshida, Fukui 910-1193 , Japan"},{"name":"Division of Radioisotope Experiments, Life Science Research Laboratory, University of Fukui , 23-3, Matsuoka-shimoaizuki, Eiheiji, Yoshida, Fukui 910-1193 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akihiro","family":"Takemura","sequence":"additional","affiliation":[{"name":"Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University , 5-11-80, Kodatsuno, Kanazawa, Ishikawa 920-0942 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akitane","family":"Oosaka","sequence":"additional","affiliation":[{"name":"Department of Radiology, Niigata Prefectural Central Hospital , 205, Shinnan, Joetsu, Niigata 943-0192 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuyuki","family":"Shirosaki","sequence":"additional","affiliation":[{"name":"Radiology Department, Toyama University Hospital , 2630, Sugitani, Toyama 930-0194 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuya","family":"Tsujikawa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Faculty of Medical Sciences, University of Fukui , 23-3, Matsuoka-shimoaizuki, Eiheiji, Yoshida, Fukui 910-1193 , Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2023,11,9]]},"reference":[{"key":"2024010202152048600_ref1","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.1118\/1.598691","article-title":"AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams","volume":"26","author":"Almond","year":"1999","journal-title":"Med. Phys."},{"volume-title":"Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water","year":"2000","author":"International Atomic Energy Agency","key":"2024010202152048600_ref2"},{"volume-title":"Standard Dosimetry of Absorbed Dose in External Beam Radiotherapy","year":"2012","author":"Japan Society of Medical Physics","key":"2024010202152048600_ref3"},{"key":"2024010202152048600_ref4","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1002\/acm2.12081","article-title":"Insight gained from responses to surveys on reference dosimetry practices","volume":"18","author":"Muir","year":"2017","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"2024010202152048600_ref5","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1002\/acm2.12159","article-title":"Comparison of AAPM addendum to TG-51, IAEA TRS-398, and JSMP 12: calibration of photon beams in water","volume":"18","author":"Kinoshita","year":"2017","journal-title":"J. Appl. Clin. Med. Phys."},{"volume-title":"Japanese Guidelines for Electrometers","author":"Japan Society of Medical Physics","key":"2024010202152048600_ref6"},{"author":"PTW","key":"2024010202152048600_ref7","article-title":"User Manual Farmer Chamber Ionization Chamber Type 30010, 30011, 30012, 30013"},{"author":"PTW","key":"2024010202152048600_ref8","article-title":"User Manual Farmer Chamber Ionization Chamber Type 30010, 30011, 30012, 30013"},{"key":"2024010202152048600_ref9","doi-asserted-by":"crossref","first-page":"041501","DOI":"10.1118\/1.4866223","article-title":"Addendum to the AAPM's TG- 51 protocol for clinical reference dosimetry of high-energy photon beams","volume":"41","author":"McEwen","year":"2014","journal-title":"Med. Phys."},{"key":"2024010202152048600_ref10","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.rpor.2018.03.001","article-title":"Uncertainty in positioning ion chamber at reference depth for various water phantoms","volume":"23","author":"Kinoshita","year":"2018","journal-title":"Rep. Pract. Oncol. Radiother."},{"key":"2024010202152048600_ref11","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1259\/0007-1285-53-629-471","article-title":"Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiation","volume":"53","author":"Boag","year":"1980","journal-title":"Br. J. Radiol."},{"key":"2024010202152048600_ref12","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.ejmp.2020.11.010","article-title":"Evaluation of ionization chamber stability checks using various sources","volume":"80","author":"Walter","year":"2020","journal-title":"Phys. Med."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/1\/106\/54919725\/ncad260.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/1\/106\/54919725\/ncad260.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,2]],"date-time":"2024-01-02T02:15:43Z","timestamp":1704161743000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/200\/1\/106\/7394849"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,9]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,11,9]]},"published-print":{"date-parts":[[2023,12,29]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncad260","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2024,1]]},"published":{"date-parts":[[2023,11,9]]}}}