{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T13:56:55Z","timestamp":1762783015056,"version":"3.37.3"},"reference-count":19,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T00:00:00Z","timestamp":1704758400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,3,20]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This case report investigates the radiation dose received by a paediatric patient with a ventricular assist device who underwent four non-contrast brain computed tomography (CT) scans, two brain perfusion CT scans and two head angiographic CT scans. The total estimated absorbed dose to the lens of the eye is above the 500\u00a0mGy radiation-induced cataract threshold. It is recommended that this patient and those with similar imaging histories have routine follow-up with an ophthalmologist. It is also recommended that radiation dose tracking and an electronic medical alert program be implemented to allow the identification of patients who may exceed tissue reaction thresholds.<\/jats:p>","DOI":"10.1093\/rpd\/ncad310","type":"journal-article","created":{"date-parts":[[2024,1,10]],"date-time":"2024-01-10T03:38:54Z","timestamp":1704857934000},"page":"417-422","source":"Crossref","is-referenced-by-count":3,"title":["Exceeding radiation thresholds for cataract induction in diagnostic imaging: a paediatric case report"],"prefix":"10.1093","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2809-1886","authenticated-orcid":false,"given":"Amanda Alison","family":"Perdomo","sequence":"first","affiliation":[{"name":"Department of Physics, University of Adelaide , Adelaide 5005, South Australia , Australia"},{"name":"Department of Medical Imaging, The Royal Children\u2019s Hospital , 50 Flemington Road, Parkville 3052, Victoria , Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed Khaldoun","family":"Badawy","sequence":"additional","affiliation":[{"name":"Monash Health Imaging, Monash Health , 246 Clayton Rd, Clayton 3168, Victoria , Australia"},{"name":"Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University , Clayton 3800, VIC , Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristina","family":"Mignone","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, The Royal Children\u2019s Hospital , 50 Flemington Road, Parkville 3052, Victoria , Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jake Cameron","family":"Forster","sequence":"additional","affiliation":[{"name":"Department of Physics, University of Adelaide , Adelaide 5005, South Australia , Australia"},{"name":"Medical Physics & Radiation Safety, South Australia Medical Imaging , Adelaide 5005, South Australia , Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,1,9]]},"reference":[{"issue":"1\u20132","key":"2024032016445614400_ref1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP PUBLICATION 118: ICRP Statement on tissue reactions and early and late effects of radiation in normal tissues and organs \u2014 threshold doses for tissue reactions in a radiation protection context. Clement CH, editor","volume":"41","author":"Stewart","year":"2012","journal-title":"Ann. ICRP"},{"issue":"1","key":"2024032016445614400_ref2","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1038\/s41572-022-00337-x","article-title":"Childhood stroke","volume":"8","author":"Sporns","year":"2022","journal-title":"Nat. Rev. Dis. Primers."},{"issue":"6","key":"2024032016445614400_ref3","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1056\/NEJMoa1014164","article-title":"Prospective trial of a pediatric ventricular assist device","volume":"367","author":"Fraser","year":"2012","journal-title":"N. Engl. J. Med."},{"issue":"12","key":"2024032016445614400_ref4","doi-asserted-by":"crossref","first-page":"1570","DOI":"10.1055\/s-2002-35937","article-title":"CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT","volume":"174","author":"Stamm","year":"2002","journal-title":"Rofo."},{"issue":"6","key":"2024032016445614400_ref5","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.13625","article-title":"Comparison of organ and effective dose estimations from different Monte Carlo simulation-based software methods in infant CT and comparison with direct phantom measurements","volume":"23","author":"Lawson","year":"2022","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"2024032016445614400_ref6","first-page":"1030","volume-title":"The essential physics of medical imaging","author":"Bushberg","year":"2012","edition":"3rd"},{"year":"2020","author":"BIR","key":"2024032016445614400_ref7"},{"issue":"1","key":"2024032016445614400_ref8","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1186\/s13244-021-01085-4","article-title":"European consensus on patient contact shielding","volume":"12","author":"Hiles","year":"2021","journal-title":"Insights Imaging."},{"key":"2024032016445614400_ref9"},{"year":"2019","author":"Australian Radiation Protection and Nuclear Safety Agency","key":"2024032016445614400_ref10"},{"issue":"1","key":"2024032016445614400_ref11","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1097\/RCT.0b013e3182a3f9a0","article-title":"Radiation exposure in perfusion CT of the brain","volume":"38","author":"Ringelstein","year":"2014","journal-title":"J. Comput. Assist. Tomogr."},{"year":"2016","author":"AAPM","key":"2024032016445614400_ref12"},{"issue":"11","key":"2024032016445614400_ref13","doi-asserted-by":"crossref","first-page":"3408","DOI":"10.1093\/brain\/awr257","article-title":"Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke","volume":"134","author":"Bivard","year":"2011","journal-title":"Brain"},{"volume-title":"Med Phys","year":"2020","key":"2024032016445614400_ref14"},{"author":"AAPM","key":"2024032016445614400_ref15"},{"key":"2024032016445614400_ref16"},{"issue":"6","key":"2024032016445614400_ref17","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1111\/1754-9485.12950","article-title":"Radiation dose and risk to the lens of the eye during CT examinations of the brain","volume":"63","author":"Poon","year":"2019","journal-title":"J. Med. Imaging Radiat. Oncol."},{"issue":"4","key":"2024032016445614400_ref18","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1667\/RR14276.1","article-title":"The risk of cataract among survivors of childhood and adolescent cancer: a report from the childhood cancer survivor study","volume":"185","author":"Chodick","year":"2016","journal-title":"Radiat. Res."},{"issue":"S2","key":"2024032016445614400_ref19","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s12055-019-00820-3","article-title":"Pediatric heart transplantation: long-term outcomes","volume":"36","author":"Dipchand","year":"2020","journal-title":"Indian J. Thorac. Cardiovasc. Surg."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/4\/417\/57027523\/ncad310.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/4\/417\/57027523\/ncad310.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,20]],"date-time":"2024-03-20T16:45:08Z","timestamp":1710953108000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/200\/4\/417\/7513650"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,9]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,1,9]]},"published-print":{"date-parts":[[2024,3,20]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncad310","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2024,3]]},"published":{"date-parts":[[2024,1,9]]}}}