{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T06:28:39Z","timestamp":1791440919316,"version":"4.3.3"},"reference-count":54,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T00:00:00Z","timestamp":1710374400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["21K15819"],"award-info":[{"award-number":["21K15819"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,4,20]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study aimed to assess fetal radiation exposure in pregnant women undergoing computed tomography (CT) and rotational angiography (RA) examinations for the diagnosis of pelvic trauma. In addition, this study aimed to compare the dose distributions between the two examinations. Surface and average fetal doses were estimated during CT and RA examinations using a pregnant phantom model and real-time dosemeters. The pregnant model phantom was constructed using an anthropomorphic phantom, and a custom-made abdominal phantom was used to simulate pregnancy. The total average fetal dose received by pregnant women from both CT scans (plain, arterial and equilibrium phases) and a single RA examination was ~60\u00a0mGy. Because unnecessary repetition of radiographic examinations, such as CT or conventional 2D angiography can increase the radiation risk, the irradiation range should be limited, if necessary, to reduce overall radiation exposure.<\/jats:p>","DOI":"10.1093\/rpd\/ncae058","type":"journal-article","created":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T06:59:48Z","timestamp":1710485988000},"page":"580-587","source":"Crossref","is-referenced-by-count":3,"title":["Assessment of fetal radiation exposure in pregnant women undergoing computed tomography and rotational angiography examinations for pelvic trauma"],"prefix":"10.1093","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2356-9385","authenticated-orcid":false,"given":"Yuta","family":"Matsunaga","sequence":"first","affiliation":[{"name":"Department of Imaging, Nagoya Kyoritsu Hospital , 1-172, Hokke, Nakagawa-ku, Nagoya, Aichi , Japan"},{"name":"Department of Radiological Technology , Faculty of Health Sciences, , 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi , Japan"},{"name":"Tohoku University Graduate School of Medicine , Faculty of Health Sciences, , 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi , Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomonobu","family":"Haba","sequence":"additional","affiliation":[{"name":"Faculty of Radiological Technology, School of Medical Science, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho,Toyoake, Aichi , Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0273-0755","authenticated-orcid":false,"given":"Masanao","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Faculty of Radiological Technology, School of Medical Science, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho,Toyoake, Aichi , Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shoichi","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Faculty of Radiological Technology, School of Medical Science, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho,Toyoake, Aichi , Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9559-4811","authenticated-orcid":false,"given":"Yasuki","family":"Asada","sequence":"additional","affiliation":[{"name":"Faculty of Radiological Technology, School of Medical Science, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho,Toyoake, Aichi , Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Chida","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology , Faculty of Health Sciences, , 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi , Japan"},{"name":"Tohoku University Graduate School of Medicine , Faculty of Health Sciences, , 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi , Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,3,14]]},"reference":[{"issue":"2","key":"2024042206062530700_ref1","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1177\/0310057X0503300204","article-title":"The pregnant trauma patient","volume":"33","author":"Weinberg","year":"2005","journal-title":"Anaesth. Intensive Care"},{"issue":"1","key":"2024042206062530700_ref2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ajog.2013.01.021","article-title":"Trauma in pregnancy\u00a0: an updated systematic review","volume":"209","author":"Mendez-figueroa","year":"2013","journal-title":"Am. J. Obstet. Gynecol."},{"issue":"1","key":"2024042206062530700_ref3","first-page":"189","article-title":"Obstetrics and Gynecology practice guidelines obstetrics edition 2008","year":"2008","journal-title":"Japan Soc. Obstet. Gynecol. Japan Assoc. Obstet. Gynecol."},{"key":"2024042206062530700_ref4","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/j.injury.2008.11.023","article-title":"Haemodynamically unstable pelvic fractures \u00a7","volume":"40","author":"White","year":"2009","journal-title":"Injury"},{"key":"2024042206062530700_ref5","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1097\/00000658-199006000-00008","article-title":"Definitive control of mortality severe pelvic fracture from","volume":"211","author":"Flint","year":"1990","journal-title":"Ann. Surg."},{"key":"2024042206062530700_ref6","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/j.amjsurg.2005.05.050","article-title":"The outcome of open pelvic fractures in the modern era","volume":"190","author":"Dente","year":"2005","journal-title":"Am. J. Surg."},{"issue":"1","key":"2024042206062530700_ref7","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/s13017-019-0248-z","article-title":"Hemostasis as soon as possible? The role of the time to angioembolization in the management of pelvic fracture","volume":"14","author":"Chou","year":"2019","journal-title":"World J. Emerg. Surg."},{"issue":"5","key":"2024042206062530700_ref8","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/j.ejrad.2011.02.049","article-title":"The role of arterial embolization in controlling pelvic fracture haemorrhage: a systematic review of the literature","volume":"81","author":"Papakostidis","year":"2012","journal-title":"Eur. J. Radiol."},{"issue":"2020","key":"2024042206062530700_ref9","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.ejmp.2020.12.003","article-title":"A new cone-beam computed tomography dosimetry method providing optimal measurement positions\u00a0: a Monte Carlo study","volume":"81","author":"Haba","year":"2021","journal-title":"Phys. Medica"},{"issue":"3","key":"2024042206062530700_ref10","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1093\/rpd\/ncz298","article-title":"Treatment of internal carotid aneurysms using pipeline embolization devices: measuring the radiation dose of the patient and determining the factors affecting it","volume":"188","author":"Kawauchi","year":"2020","journal-title":"Radiat. Prot. Dosim."},{"issue":"2","key":"2024042206062530700_ref11","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1093\/rpd\/ncy188","article-title":"Estimation of patient lens dose associated with c-arm cone-beam computed tomography usage during interventional neuroradiology","volume":"184","author":"Kawauchi","year":"2019","journal-title":"Radiat. Prot. Dosim."},{"issue":"5","key":"2024042206062530700_ref12","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.3390\/tomography9050134","article-title":"Image quality and radiation dose of conventional and wide-field high-resolution cone-beam computed tomography for cerebral angiography: a phantom study","volume":"9","author":"Kawauchi","year":"2023","journal-title":"Tomography"},{"issue":"5","key":"2024042206062530700_ref13","first-page":"418","article-title":"Three-dimensional rotational angiography is preferable to conventional two-dimensional techniques for uterine artery embolization","volume":"19","author":"Gupta","year":"2013","journal-title":"Diagnostic Interv. Radiol."},{"issue":"4","key":"2024042206062530700_ref14","doi-asserted-by":"crossref","first-page":"W224","DOI":"10.2214\/AJR.07.2422","article-title":"Total entrance skin dose: an effective indicator of maximum radiation dose to the skin during percutaneous coronary intervention., AJR","volume":"189","author":"Chida","year":"2007","journal-title":"Am. J. Roentgenol."},{"issue":"3","key":"2024042206062530700_ref15","doi-asserted-by":"crossref","first-page":"774","DOI":"10.2214\/AJR.04.1653","article-title":"Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures","volume":"186","author":"Chida","year":"2006","journal-title":"Am. J. Roentgenol."},{"issue":"1","key":"2024042206062530700_ref16","first-page":"31","article-title":"Direct dose measurement on patient during percutaneous coronary intervention procedures","volume":"175","author":"Kato","year":"2017","journal-title":"Radiat. Prot. Dosim."},{"issue":"3","key":"2024042206062530700_ref17","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1007\/s12194-020-00575-2","article-title":"An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology","volume":"13","author":"Inaba","year":"2020","journal-title":"Radiol. Phys. Technol."},{"issue":"4","key":"2024042206062530700_ref18","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.2214\/ajr.183.4.1831111","article-title":"Does digital acquisition reduce patients\u2019 skin dose in cardiac interventional procedures? An experimental study","volume":"183","author":"Chida","year":"2004","journal-title":"Am. J. Roentgenol."},{"issue":"3","key":"2024042206062530700_ref19","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1080\/AC.70.3.3080634","article-title":"Radiation dose of cardiac IVR x-ray systems: a comparison of present and past","volume":"70","author":"Inaba","year":"2015","journal-title":"Acta Cardiol."},{"issue":"1","key":"2024042206062530700_ref20","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1002\/ccd.20961","article-title":"Patient skin dose in cardiac interventional procedures\u00a0: conventional fluoroscopy versus pulsed fluoroscopy","volume":"69","author":"Chida","year":"2007","journal-title":"Catheter. Cardiovasc. Interv."},{"issue":"1","key":"2024042206062530700_ref21","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1007\/s12194-008-0044-z","article-title":"Evaluating the performance of a MOSFET dosimeter at diagnostic X-ray energies for interventional radiology","volume":"2","author":"Chida","year":"2009","journal-title":"Radiol. Phys. Technol."},{"issue":"3","key":"2024042206062530700_ref22","doi-asserted-by":"crossref","first-page":"031518","DOI":"10.1088\/1361-6498\/acf868","article-title":"Evaluation of radiation dose and image quality for dental cone-beam computed tomography in pediatric patients","volume":"43","author":"Ito","year":"2023","journal-title":"J. Radiol. Prot."},{"issue":"2","key":"2024042206062530700_ref23","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1002\/acm2.13171","article-title":"Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: a phantom study","volume":"22","author":"Matsunaga","year":"2021","journal-title":"J. Appl. Clin. Med. Phys."},{"issue":"5","key":"2024042206062530700_ref24","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1002\/acm2.12154","article-title":"Fetal dose conversion factor for fetal computed tomography examinations: a mathematical phantom study","volume":"18","author":"Matsunaga","year":"2017","journal-title":"J. Appl. Clin. Med. Phys."},{"issue":"4","key":"2024042206062530700_ref25","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1093\/rpd\/ncv374","article-title":"Dose evaluation for foetal computed tomography with a 320-row unit in wide-volume mode and an 80-row unit in helical scanning mode: a phantom study","volume":"168","author":"Matsunaga","year":"2016","journal-title":"Radiat. Prot. Dosim."},{"issue":"2","key":"2024042206062530700_ref26","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s12194-016-0377-y","article-title":"Radiation doses for pregnant women in the late pregnancy undergoing fetal-computed tomography\u00a0: a comparison of dosimetry and Monte Carlo simulations","volume":"10","author":"Matsunaga","year":"2017","journal-title":"Radiol. Phys. Technol."},{"issue":"2","key":"2024042206062530700_ref27","doi-asserted-by":"crossref","first-page":"e13884","DOI":"10.1002\/acm2.13884","article-title":"Evaluation of radiation dose for inferior vena cava filter placement during pregnancy: a comparison of dosimetry and dose calculation software","volume":"24","author":"Matsunaga","year":"2023","journal-title":"J. Appl. Clin. Med. Phys."},{"issue":"2","key":"2024042206062530700_ref28","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s12194-022-00660-8","article-title":"What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?","volume":"15","author":"Chida","year":"2022","journal-title":"Radiol. Phys. Technol."},{"issue":"2","key":"2024042206062530700_ref29","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1269\/jrr.09112","article-title":"Radiation dose and radiation protection for patients and physicians during interventional procedure","volume":"51","author":"Chida","year":"2010","journal-title":"J. Radiat. Res."},{"issue":"1","key":"2024042206062530700_ref30","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1038\/s41598-017-00556-3","article-title":"Occupational eye dose in interventional cardiology procedures","volume":"7","author":"Haga","year":"2017","journal-title":"Sci. Rep."},{"issue":"2","key":"2024042206062530700_ref31","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1093\/rpd\/ncy285","article-title":"Occupational radiation exposure of the eye in neurovascular interventional physician","volume":"185","author":"Kato","year":"2019","journal-title":"Radiat. Prot. Dosim."},{"issue":"1","key":"2024042206062530700_ref32","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1007\/s12194-022-00650-w","article-title":"Occupational eye dose correlation with neck dose and patient - related quantities in interventional cardiology procedures","volume":"15","author":"Ishii","year":"2022","journal-title":"Radiol. Phys. Technol."},{"issue":"4","key":"2024042206062530700_ref33","first-page":"409","article-title":"A phantom study to determine the optimal placement of eye dosemeters on interventional cardiology staff","volume":"185","author":"Ishii","year":"2019","journal-title":"Radiat. Prot. Dosim."},{"issue":"2007","key":"2024042206062530700_ref34","first-page":"1","article-title":"Recommendations of the international commission on radiological protection","volume":"103","author":"The International Commission on Radiological Protection. The","year":"2007","journal-title":"ICRP publication"},{"issue":"3","key":"2024042206062530700_ref35","doi-asserted-by":"crossref","first-page":"N12","DOI":"10.1088\/1361-6498\/ac125c","article-title":"Novel pregnant model phantoms for measurement of foetal radiation dose in x-ray examinations","volume":"41","author":"Matsunaga","year":"2021","journal-title":"J. Radiol. Prot."},{"issue":"12","key":"2024042206062530700_ref36","first-page":"763","article-title":"A study on how to design comfortable maternity trousers which adjust to body changes during pregnancy","volume":"58","author":"Okabe","year":"2007","journal-title":"J. Home Econ. Japan"},{"issue":"2","key":"2024042206062530700_ref37","doi-asserted-by":"crossref","first-page":"W202","DOI":"10.2214\/AJR.14.13925","article-title":"Novel dosimeter using a nontoxic phosphor for real-time monitoring of patient radiation dose in interventional radiology","volume":"205","author":"Nakamura","year":"2015","journal-title":"Am. J. Roentgenol."},{"issue":"11","key":"2024042206062530700_ref38","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1016\/j.ejmp.2016.10.013","article-title":"Real-time patient radiation dosimeter for use in interventional radiology","volume":"32","author":"Chida","year":"2016","journal-title":"Phys. Medica"},{"issue":"4","key":"2024042206062530700_ref39","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/s12194-018-0484-z","article-title":"Effectiveness of a novel real-time dosimeter in interventional radiology: a comparison of new and old radiation sensors","volume":"11","author":"Inaba","year":"2018","journal-title":"Radiol. Phys. Technol."},{"issue":"2","key":"2024042206062530700_ref40","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1093\/jrr\/rry110","article-title":"New real-time patient radiation dosimeter for use in radiofrequency catheter ablation","volume":"60","author":"Kato","year":"2019","journal-title":"J. Radiat. Res."},{"issue":"4","key":"2024042206062530700_ref41","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1093\/rpd\/ncu340","article-title":"Effect of tube current modulation for dose estimation using a simulation tool on body CT examination","volume":"167","author":"Kawaguchi","year":"2015","journal-title":"Radiat. Prot. Dosim."},{"issue":"5","key":"2024042206062530700_ref42","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.2214\/AJR.10.4466","article-title":"Radiation dose to the pediatric cardiac catheterization and intervention patient","volume":"195","author":"Chida","year":"2010","journal-title":"Am. J. Roentgenol."},{"issue":"5","key":"2024042206062530700_ref43","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1111\/j.1754-9485.2011.02293.x","article-title":"Relationship between specific organ doses and volumetric CT dose indices in multidetector CT studies","volume":"55","author":"Matsubara","year":"2011","journal-title":"J. Med. Imaging Radiat. Oncol."},{"issue":"1052","key":"2024042206062530700_ref44","doi-asserted-by":"crossref","first-page":"20150219","DOI":"10.1259\/bjr.20150219","article-title":"Survey of volume CT dose index in Japan in 2014","volume":"88","author":"Matsunaga","year":"2015","journal-title":"Br. J. Radiol."},{"issue":"1058","key":"2024042206062530700_ref45","doi-asserted-by":"crossref","first-page":"20150671","DOI":"10.1259\/bjr.20150671","article-title":"Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study","volume":"89","author":"Matsunaga","year":"2016","journal-title":"Br. J. Radiol."},{"issue":"1094","key":"2024042206062530700_ref46","doi-asserted-by":"crossref","first-page":"20180290","DOI":"10.1259\/bjr.20180290","article-title":"Diagnostic reference levels and achievable doses for common computed tomography examinations: results from the Japanese nationwide dose survey","volume":"92","author":"Matsunaga","year":"2019","journal-title":"Br. J. Radiol."},{"issue":"2","key":"2024042206062530700_ref47","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1093\/rpd\/ncz284","article-title":"Volume CT dose index and dose-length product values according to facility size in Japan","volume":"188","author":"Matsunaga","year":"2020","journal-title":"Radiat. Prot. Dosim."},{"issue":"4","key":"2024042206062530700_ref48","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1093\/rpd\/ncx017","article-title":"Patient exposure during plain radiography and mammography in Japan in 1974\u20132014","volume":"176","author":"Matsunaga","year":"2017","journal-title":"Radiat. Prot. Dosim."},{"issue":"3","key":"2024042206062530700_ref49","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1088\/1361-6498\/aba083","article-title":"Proposed diagnostic reference levels for general radiography and mammography in Japan","volume":"40","author":"Asada","year":"2020","journal-title":"J. Radiol. Prot."},{"key":"2024042206062530700_ref50","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s12194-011-0121-6","article-title":"Comparison of dose at an interventional reference point between the displayed estimated value and measured value","volume":"4","author":"Chida","year":"2011","journal-title":"Radiol. Phys. Technol."},{"issue":"1","key":"2024042206062530700_ref51","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1093\/rpd\/ncq287","article-title":"Comparison of the radiation dose in a cardiac IVR X-ray system","volume":"143","author":"Inaba","year":"2011","journal-title":"Radiat. Prot. Dosim."},{"issue":"7","key":"2024042206062530700_ref52","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1007\/s00247-012-2381-7","article-title":"Prenatal diagnosis of fetal skeletal dysplasia with 3D CT","volume":"42","author":"Miyazaki","year":"2012","journal-title":"Pediatr. Radiol."},{"key":"2024042206062530700_ref53","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ejmp.2024.103215","article-title":"Estimating organ dose with optimized peak dose index in cone-beam CT scans","volume":"118","author":"Haba","year":"2024","journal-title":"Phys. Medica"},{"issue":"9","key":"2024042206062530700_ref54","doi-asserted-by":"crossref","DOI":"10.3390\/s20092741","article-title":"Development of novel real-time radiation systems using 4-channel sensors","volume":"20","author":"Inaba","year":"2020","journal-title":"Sensors"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/6\/580\/57297159\/ncae058.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/6\/580\/57297159\/ncae058.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T06:07:08Z","timestamp":1713766028000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/200\/6\/580\/7628864"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,14]]},"references-count":54,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,3,14]]},"published-print":{"date-parts":[[2024,4,20]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncae058","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,4]]},"published":{"date-parts":[[2024,3,14]]}}}