{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:57:07Z","timestamp":1740139027032,"version":"3.37.3"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"15","license":[{"start":{"date-parts":[[2024,8,31]],"date-time":"2024-08-31T00:00:00Z","timestamp":1725062400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,9,19]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The benefits of a cardiac resynchronization therapy (CRT) implantation are known in severe heart failure and its implantation may also be considered during pregnancy to ensure safe pregnancy and delivery for both the mother and the fetus. This study on a patient case aimed to estimate the absorbed dose (AD) to the fetus during the CRT implantation of 21st week of the pregnant woman. AD measurement was done using anthropomorphic phantom, radiophotoluminescence dosemeters and Monte Carlo simulation utilizing kerma area product (KAP) of the procedures. The measured AD for a phantom\u2019s uterus and heart was 0.116 and 14.7\u00a0mGy with total KAP of 27.9 Gycm2. The estimated actual AD to the fetus and the mother\u2019s heart was 0.004 and 1.2\u00a0mGy, with total KAP of 1.5 Gycm2. The dose to the fetus can be minimized with the optimized procedure.<\/jats:p>","DOI":"10.1093\/rpd\/ncae182","type":"journal-article","created":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T01:07:07Z","timestamp":1725152827000},"page":"1477-1485","source":"Crossref","is-referenced-by-count":0,"title":["Implantation of CRT pacemaker during pregnancy: estimated fetal radiation dose"],"prefix":"10.1093","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9366-1703","authenticated-orcid":false,"given":"Anna-Leena","family":"Manninen","sequence":"first","affiliation":[{"name":"Oulu University Hospital Department of Diagnostic Radiology, , PO Box 10, FI-90029 Oulu, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5110-5705","authenticated-orcid":false,"given":"Jukka","family":"J\u00e4rvinen","sequence":"additional","affiliation":[{"name":"Turku University Hospital Turku Heart Center, Department of Cardiology, , PO Box 52, 20521 Turku, Finland"},{"name":"Turku University Hospital Medical Imaging Centre of Southwest Finland, Department of Radiology, , PO Box 52, 20521 Turku, Finland"},{"name":"Turku University Hospital Department of Medical Physics, , PO Box 52, 20521 Turku, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joanna","family":"Sierpowska","sequence":"additional","affiliation":[{"name":"Central Hospital of North Karelia Department of Radiology, , FI-80210 Joensuu, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timo J","family":"M\u00e4kel\u00e4","sequence":"additional","affiliation":[{"name":"Oulu University Hospital, Pohde OYS Heart Center, , PO Box 10, FI-90029 Oulu, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tuomas T","family":"Rissanen","sequence":"additional","affiliation":[{"name":"Central Hospital of North Karelia, Siunsote Heart Center, , FI-80210 Joensuu, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,8,31]]},"reference":[{"key":"2024092009155198000_ref1","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/00006254-198703000-00002","article-title":"Pregnancy with an artificial pacemaker","volume":"42","author":"Jaffe","year":"1987","journal-title":"Obstet Gynecol Surv"},{"key":"2024092009155198000_ref2","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/S0020-7292(99)00206-4","article-title":"Successful pregnancy outcome with cardiac pacemaker after complete heart block","volume":"68","author":"Sharma","year":"2000","journal-title":"Int J Gynaecol Obstet"},{"key":"2024092009155198000_ref3","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1093\/europace\/eur018","article-title":"Cardiac outcome of pregnancy in women with a pacemaker and women with untreated atrioventricular conduction block","volume":"13","author":"Thaman","year":"2011","journal-title":"Europace"},{"key":"2024092009155198000_ref4","first-page":"2281","article-title":"ESC guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"34","author":"Brignole","year":"2013","journal-title":"Eur Heart J"},{"key":"2024092009155198000_ref5","doi-asserted-by":"crossref","first-page":"3147","DOI":"10.1093\/eurheartj\/ehr218","article-title":"ESC guidelines on the management of cardiovascular diseases during pregnancy","volume":"32","author":"Regitz-Zagrosek","year":"2011","journal-title":"Eur Heart J"},{"key":"2024092009155198000_ref6","first-page":"1533","article-title":"ESC guidelines on cardiac pacing and cardiac resynchronization therapy: addenda","volume":"15","author":"Brignole","year":"2013","journal-title":"Eur Heart J"},{"key":"2024092009155198000_ref7","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1093\/europace\/eut409","article-title":"Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures","volume":"16","author":"Heidbuchel","year":"2014","journal-title":"Europace"},{"key":"2024092009155198000_ref8","first-page":"483","article-title":"Contemporary radiation doses in interventional cardiology: a nationwide study of patient doses in Finland","volume":"185","author":"J\u00e4rvinen, Sierpowska","year":"2019","journal-title":"Radiat Prot Dosim"},{"key":"2024092009155198000_ref9","doi-asserted-by":"crossref","DOI":"10.1093\/rpd\/ncz041","article-title":"Contemporary radiation doses in interventional cardiology: A nationwide study of patient skin doses in Finland","author":"J\u00e4rvinen","year":"2019","journal-title":"Radiat Prot Dosim"},{"key":"2024092009155198000_ref10","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.jvir.2011.09.007","article-title":"Radiation management for interventions using fluoroscopic or computed tomographic guidance during pregnancy: a joint guideline of the Society of Interventional Radiology and the Cardiovascular and Interventional Radiological Society of Europe with endorsement by the Canadian Interventional Radiology Association","volume":"23","author":"Dauer","year":"2012","journal-title":"J Vasc Interv Radiol"},{"key":"2024092009155198000_ref11","doi-asserted-by":"crossref","first-page":"33","DOI":"10.3109\/02841850903229141","article-title":"Optimizing patient radiation dose in interventional procedures","volume":"51","author":"Chida","year":"2010","journal-title":"Acta Radiol"},{"key":"2024092009155198000_ref12","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1148\/rg.274065149","article-title":"Radiation exposure and pregnancy: when should we be concerned?","volume":"27","author":"McCollough","year":"2007","journal-title":"Radiographics"},{"key":"2024092009155198000_ref13","first-page":"1","article-title":"Radiological protection in medicine. ICRP Publication 105","volume":"37","author":"International Commission on Radiologic Protection (ICRP)","year":"2008","journal-title":"Ann ICRP"},{"key":"2024092009155198000_ref14","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1186\/s13244-021-01085-4","article-title":"European consensus on patient contact shielding","volume":"12","author":"Hiles","year":"2021","journal-title":"Insights Imaging"},{"volume-title":"Exposure of the Pregnant Patient to Diagnostic Radiations: A Guide to Medical Management","year":"1997","author":"Wagner","key":"2024092009155198000_ref15"},{"key":"2024092009155198000_ref16","doi-asserted-by":"crossref","first-page":"117","DOI":"10.4103\/0972-0464.194966","article-title":"What can we tell people about the health effects of radiation exposure?","volume":"39","author":"Wrixon","year":"2016","journal-title":"Radiat Prot Environ"},{"key":"2024092009155198000_ref17","first-page":"1","article-title":"The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"2024092009155198000_ref18","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.2459\/JCM.0b013e3283100edc","article-title":"Implantation of a permanent pacemaker in a pregnant woman under the guidance of electrophysiologic signals and transthoracic echocardiography","volume":"9","author":"Pedrinazzi","year":"2008","journal-title":"J Cardiovasc Med (Hagerstown)"},{"key":"2024092009155198000_ref19","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1590\/S0066-782X2009000500017","article-title":"Permanent pacemaker implantation in a pregnant woman with rheumatic mitral valve disease","volume":"92","author":"Esper","year":"2009","journal-title":"Arq Bras Cardiol"},{"key":"2024092009155198000_ref20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1093\/rpd\/ncr463","article-title":"The applicability of radiophotoluminescence dosemeter (RPLD) for measuring medical radiation (MR) doses","volume":"151","author":"Manninen","year":"2012","journal-title":"Radiat Prot Dosim"},{"author":"Tapiovaara","key":"2024092009155198000_ref21"},{"key":"2024092009155198000_ref22","first-page":"1","article-title":"Radiological protection in cardiology. ICRP Publication 120","volume":"42","year":"2013","journal-title":"Ann ICRP"},{"year":"2004","author":"Hubbell","key":"2024092009155198000_ref23"},{"key":"2024092009155198000_ref24","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","author":"McCollough","year":"2009","journal-title":"Radiol Clin North Am"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/15\/1477\/59199637\/ncae182.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/15\/1477\/59199637\/ncae182.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,20]],"date-time":"2024-09-20T09:16:07Z","timestamp":1726823767000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/200\/15\/1477\/7746418"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,31]]},"references-count":24,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2024,8,31]]},"published-print":{"date-parts":[[2024,9,19]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncae182","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2024,9]]},"published":{"date-parts":[[2024,8,31]]}}}