{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T21:46:53Z","timestamp":1764020813457,"version":"3.37.3"},"reference-count":23,"publisher":"Oxford University Press (OUP)","issue":"19","license":[{"start":{"date-parts":[[2024,10,12]],"date-time":"2024-10-12T00:00:00Z","timestamp":1728691200000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"State Research Funding of the Turku University Hospital"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,18]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The effect of patient shielding on fetal radiation dose was evaluated in computed tomography pulmonary angiography with the out-of-plane shield visible in the localizer but absent in the scan range in chest computed tomography (CT). An anthropomorphic phantom with additional prosthetic pregnancy belly was scanned with different CT scanners using clinical imaging protocols and radiophotoluminescence dosemeters (GD-352\u00a0M). The out-of-plane shield decreased the fetal absorbed radiation dose with Siemens Somatom go.Up, Canon Aquilion Prime SP and Canon Aquilion One scanners. The decrease was 3.9%\u201339.4% (0.01\u20130.09\u00a0mGy). With GE Optima the shield increased the fetal dose by 100% (0.23\u00a0mGy), with Canon Aquilion One and GE Optima scanners the abdomen dose increase was 17.5% and 36.4%, respectively (0.61 and 1.38\u00a0mGy). Applying an out-of-plane shield outside the scanned volume may increase the fetal radiation dose during CT when using tube current modulation, depending on the make and model of the CT scanner.<\/jats:p>","DOI":"10.1093\/rpd\/ncae204","type":"journal-article","created":{"date-parts":[[2024,10,12]],"date-time":"2024-10-12T02:42:43Z","timestamp":1728700963000},"page":"1945-1949","source":"Crossref","is-referenced-by-count":2,"title":["The out-of-plane contact shield and mA-modulation\u00a0\u2013 the effect on fetal absorbed dose"],"prefix":"10.1093","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6428-0556","authenticated-orcid":false,"given":"Heli R S","family":"Larjava","sequence":"first","affiliation":[{"name":"Department of Medical Physics and Department of Radiology, Turku University Hospital and University of Turku , 20521 Turku,","place":["Finland"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chibuzor T M","family":"Eneh","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Department of Radiology, Turku University Hospital and University of Turku , 20521 Turku,","place":["Finland"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aleksi","family":"Saikkonen","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Turku University Hospital and University of Turku , 20521 Turku,","place":["Finland"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riitta K","family":"Parkkola","sequence":"additional","affiliation":[{"name":"Department of Radiology, Turku University Hospital and University of Turku , 20521 Turku,","place":["Finland"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,10,11]]},"reference":[{"volume-title":"The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication","year":"2007)","author":"International Commission on Radiation Protection (ICRP)","key":"2024111813541738900_ref1"},{"key":"2024111813541738900_ref2","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study","volume":"380","author":"Pearce","year":"2012","journal-title":"Lancet"},{"key":"2024111813541738900_ref3","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/S1470-2045(22)00655-6","article-title":"Brain cancer after radiation exposure from CT examinations of children and young adults: results from the EPI-CT cohort study","volume":"24","author":"Hauptmann","year":"2023","journal-title":"Lancet Oncol"},{"key":"2024111813541738900_ref4","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1007\/s00247-023-05638-1","article-title":"Dose length product to effective dose coefficients in children","volume":"53","author":"Chu","year":"2023","journal-title":"Pediatr Radiol"},{"key":"2024111813541738900_ref5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.10.001","article-title":"Radiological protection in paediatric diagnostic and interventional radiology. ICRP publication 121","volume":"42","author":"International Commission on Radiation Protection","year":"2013","journal-title":"Ann ICRP"},{"volume-title":"Radiation Protection and Safety in Medical Uses of Ionizing Radiation","year":"2018","author":"International Atomic Energy Agency","key":"2024111813541738900_ref6"},{"key":"2024111813541738900_ref7","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/j.ejmp.2021.12.006","article-title":"European consensus on patient contact shielding","volume":"96","author":"Hiles","year":"2022","journal-title":"Physica Medica"},{"volume-title":"AAPM Position Statement on the Use of Patient Gonadal and Fetal Shielding","year":"2019","author":"American Association of Physicist in Medicine (AAPM)","key":"2024111813541738900_ref8"},{"key":"2024111813541738900_ref9","first-page":"311","article-title":"technologists' radiation exposure perceptions and practices","volume":"82","author":"Johnston","year":"2011","journal-title":"Radiol Technol"},{"volume-title":"Guidance on using shielding on patients for diagnostic radiology applications","year":"2020","author":"British Institute of Radiology","key":"2024111813541738900_ref10"},{"key":"2024111813541738900_ref11","doi-asserted-by":"publisher","first-page":"503","DOI":"10.2214\/AJR.12.9997","article-title":"To shield or not to shield: application of bismuth breast shields","volume":"200","author":"Colletti","year":"2013","journal-title":"AJR"},{"key":"2024111813541738900_ref12","first-page":"1","article-title":"Pregnancy-related mortality surveillance \u2013 United States, 1991\u20131999. In surveillance summaries, February 21, 2023","volume":"52","author":"Chang","year":"2003","journal-title":"MMWR Surveill Summ"},{"key":"2024111813541738900_ref13","doi-asserted-by":"publisher","first-page":"1628","DOI":"10.1016\/j.chest.2021.11.036","article-title":"Comparison of guidelines for evaluation of suspected pulmonary embolism in pregnancy. A cost-effectiveness analysis","volume":"161","author":"McCandlish","year":"2022","journal-title":"Chest"},{"key":"2024111813541738900_ref14","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1016\/S0140-6736(09)60996-X","article-title":"Pulmonary embolism in pregnancy","volume":"375","author":"Bourjeily","year":"2011","journal-title":"Lancet"},{"key":"2024111813541738900_ref15","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1148\/rg.274065149","article-title":"Radiation exposure and pregnancy: when should we be concerned?","volume":"27","author":"McCollough","year":"2007","journal-title":"Radiographics"},{"key":"2024111813541738900_ref16","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ejmp.2017.09.120","article-title":"Fetal radiation dose in three common CT examinations during pregnancy \u2013 Monte Carlo study","volume":"43","author":"Kelaranta","year":"2017","journal-title":"Physica Medica"},{"key":"2024111813541738900_ref17","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1093\/rpd\/ncaa059","article-title":"To use or not to use patient shielding on pregnant women undergoing CT pulmonary angiography: a phantom study","volume":"189","author":"Begano","year":"2020","journal-title":"Rad Prot Dos"},{"key":"2024111813541738900_ref18","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-023-10211-3","article-title":"To shield or not to shield \u2013 shielding may have unintended effects on patient dose in CT","volume":"34","author":"Larjava","year":"2024","journal-title":"Eur Radiol"},{"volume-title":"Clinical Physiology in Obstetrics","year":"1980","author":"Hytten","key":"2024111813541738900_ref19"},{"volume-title":"Advances in Cancer Therapy","author":"Huang","key":"2024111813541738900_ref20","doi-asserted-by":"publisher","DOI":"10.5772\/23710"},{"key":"2024111813541738900_ref21","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.ejmp.2018.03.017","article-title":"The use of out-of-plane high Z patient shielding for fetal dose reduction in computed tomography: literature review and comparison with Monte-Carlo calculations of an alternative optimisation technique","volume":"48","author":"Ryckx","year":"2018","journal-title":"Physica Medica"},{"key":"2024111813541738900_ref22","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/s13244-010-0043-6","article-title":"Imaging for suspected pulmonary embolism in pregnancy \u2013 what about the fetal dose? A comprehensive review of the literature","volume":"1","author":"Niemann","year":"2010","journal-title":"Insights into Imaging"},{"key":"2024111813541738900_ref23","doi-asserted-by":"publisher","first-page":"e210","DOI":"10.1097\/AOG.0000000000002355","article-title":"ACOG Committee Opinion, Number 723","volume":"130","author":"The American College of Obstetricians and Gynecologists","year":"2017","journal-title":"Obstet Gynecol"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/advance-article-pdf\/doi\/10.1093\/rpd\/ncae204\/60734754\/ncae204.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/advance-article-pdf\/doi\/10.1093\/rpd\/ncae204\/60734754\/ncae204.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,18]],"date-time":"2024-11-18T13:54:30Z","timestamp":1731938070000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/200\/19\/1945\/7818329"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,11]]},"references-count":23,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2024,10,11]]},"published-print":{"date-parts":[[2024,11,18]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncae204","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2024,11]]},"published":{"date-parts":[[2024,10,11]]}}}