{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T06:50:50Z","timestamp":1765176650225,"version":"3.37.3"},"reference-count":31,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T00:00:00Z","timestamp":1732233600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,12,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>In recent decades, technological advances have been made in the field of radiotherapy and with it the emergence of new dosimetric systems for their calibration and commissioning, among other uses. Such is the case of the measurement in the build-up region, where there is no charged-particle equilibrium, which is reflected in the increase in surface dose for patient treatments and potential skin toxicities as a secondary effect. This study utilizes optically stimulated dosemeters (nanoDot) and the radiochromic film (EBT3) to measure skin doses in patients with head and neck cancer who received radiotherapy. Accurately depicting 15 patients with different diagnoses from 3 linear accelerators using 3D, intensity modulated radiation therapy, or volumetric arc therapy\/RapidArc technology, these results were compared with those calculated in the treatment planning system (TPS) and obtaining a percentage of variation for the EBT3 ranged from 0.30% to 6.15%, while that observed for the nanoDot was from 0.51% to 4.88%. This difference may be attributed to the reproducibility of placement in patients. Therefore, for clinical use, nanoDot dosemeters are a viable alternative for in vivo dosimetry where rapid validation of planning system results is required.<\/jats:p>","DOI":"10.1093\/rpd\/ncae217","type":"journal-article","created":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T12:48:45Z","timestamp":1732279725000},"page":"70-77","source":"Crossref","is-referenced-by-count":1,"title":["Implementation of OSL nanoDot dosimetry in different treatment techniques for head and neck cancer"],"prefix":"10.1093","volume":"201","author":[{"given":"Ingrid M","family":"Negrete-Hernandez","sequence":"first","affiliation":[{"name":"Instituto Polit\u00e9cnico Nacional, Centro de Investigaci\u00f3n en Ciencia Aplicada y Tecnolog\u00eda Avanzada, Unidad Legaria , Av. Legaria 694,11500, Ciudad de M\u00e9xico ,","place":["M\u00e9xico"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8380-827X","authenticated-orcid":false,"given":"Ivonne B","family":"Lozano","sequence":"additional","affiliation":[{"name":"Instituto Polit\u00e9cnico Nacional, Centro de Investigaci\u00f3n en Ciencia Aplicada y Tecnolog\u00eda Avanzada, Unidad Legaria , Av. Legaria 694,11500, Ciudad de M\u00e9xico ,","place":["M\u00e9xico"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jesus","family":"Roman-Lopez","sequence":"additional","affiliation":[{"name":"CONAHCYT-Instituto de Ciencias Nucleares, Universidad Nacional Aut\u00f3noma de M\u00e9xico, Circuito exterior S\/N, A.P. 70-543 , 04510 Ciudad de M\u00e9xico ,","place":["M\u00e9xico"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jesus I","family":"Guzman-Casta\u00f1eda","sequence":"additional","affiliation":[{"name":"Instituto Polit\u00e9cnico Nacional, Escuela Superior de Ingenier\u00eda Qu\u00edmica e Industrias Extractivas , Edificio 6, Av. Luis Enrique Erro S\/N, Unidad Profesional Adolfo L\u00f3pez Mateos, 07738 Ciudad de M\u00e9xico ,","place":["M\u00e9xico"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,11,22]]},"reference":[{"key":"2025010312565532800_ref1","doi-asserted-by":"crossref","first-page":"3178","DOI":"10.1111\/jcmm.14174","article-title":"Establishment and characterization of a radiation-induced dermatitis rat model","volume":"23","author":"Sheng","year":"2019","journal-title":"J Cell Mol Med"},{"key":"2025010312565532800_ref2","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s13555-016-0120-y","article-title":"Acute and chronic cutaneous reactions to ionizing radiation therapy","volume":"6","author":"Bray","year":"2016","journal-title":"Dermatol Ther (Heidelb)"},{"key":"2025010312565532800_ref3","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.meddos.2006.02.003","article-title":"Surface dose measurement using TLD powder extrapolation","volume":"31","author":"Rapley","year":"2006","journal-title":"Med Dosim"},{"key":"2025010312565532800_ref4","doi-asserted-by":"crossref","first-page":"3118","DOI":"10.1118\/1.1626989","article-title":"In vivo diode dosimetry for routine quality assurance in IMRT","volume":"30","author":"Higgins","year":"2003","journal-title":"Med Phys"},{"key":"2025010312565532800_ref5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1748-717X-2-7","article-title":"On the performances of different IMRT treatment planning systems for selected pediatric cases","volume":"2","author":"Fogliata","year":"2007","journal-title":"Radiat Oncol"},{"key":"2025010312565532800_ref6","doi-asserted-by":"crossref","first-page":"081720","DOI":"10.1118\/1.4890795","article-title":"Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments","volume":"41","author":"Zhuang","year":"2014","journal-title":"Med Phys"},{"key":"2025010312565532800_ref7","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.radphyschem.2017.02.017","article-title":"Skin dose for head and neck cancer patients treated with intensity-modulated radiation therapy (IMRT)","volume":"140","author":"Fu","year":"2017","journal-title":"Radiat Phys Chem"},{"key":"2025010312565532800_ref8","doi-asserted-by":"crossref","first-page":"4233","DOI":"10.31557\/APJCP.2022.23.12.4233","article-title":"A Dosimetric and radiobiological comparison of intensity modulated radiotherapy, volumetric modulated arc therapy and helical Tomotherapy planning techniques in synchronous bilateral breast cancer","volume":"23","author":"Balasubramanian","year":"2022","journal-title":"Asian Pac J Cancer Prev"},{"key":"2025010312565532800_ref9","doi-asserted-by":"crossref","first-page":"624","DOI":"10.4103\/jcrt.jcrt_234_21","article-title":"Determination and comparison of dosimetric parameters of three-dimensional conformal radiotherapy, field in field, and intensity-modulated radiotherapy techniques in radiotherapy of breast conserving patients","volume":"19","author":"Takabi","year":"2023","journal-title":"J Cancer Res Ther"},{"key":"2025010312565532800_ref10","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.ejmp.2016.10.022","article-title":"In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy","volume":"32","author":"Jong","year":"2016","journal-title":"Phys Med"},{"key":"2025010312565532800_ref11","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1120\/jacmp.v13i3.3734","article-title":"Skin dose during radiotherapy: a summary and general estimation technique","volume":"13","author":"Kry","year":"2012","journal-title":"J Appl Clin Med Phys"},{"key":"2025010312565532800_ref12","doi-asserted-by":"crossref","first-page":"247","DOI":"10.15537\/smj.2021.42.3.20210660","article-title":"Radiation therapy in head and neck cancer","volume":"42","author":"Alfouzan","year":"2021","journal-title":"Saudi Med J"},{"key":"2025010312565532800_ref13","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1118\/1.597702","article-title":"A new radiotherapy surface dose detector: the MOSFET","volume":"23","author":"Butson","year":"1996","journal-title":"Med Phys"},{"key":"2025010312565532800_ref14","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1118\/1.3030951","article-title":"In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques","volume":"36","author":"Qi","year":"2009","journal-title":"Med Phys"},{"key":"2025010312565532800_ref15","doi-asserted-by":"crossref","first-page":"2447","DOI":"10.1118\/1.3700400","article-title":"Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors","volume":"39","author":"Karsch","year":"2012","journal-title":"Med Phys"},{"key":"2025010312565532800_ref16","doi-asserted-by":"crossref","first-page":"4594","DOI":"10.1118\/1.2804555","article-title":"Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements","volume":"34","author":"Jursinic","year":"2007","journal-title":"Med Phys"},{"key":"2025010312565532800_ref17","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.radmeas.2014.03.023","article-title":"State of art: optically stimulated luminescence dosimetry \u2013 frontiers of future research","volume":"71","author":"Yukihara","year":"2014","journal-title":"Radiat Meas"},{"key":"2025010312565532800_ref18","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1118\/1.2816106","article-title":"Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy","volume":"35","author":"Yukihara","year":"2008","journal-title":"Med Phys"},{"key":"2025010312565532800_ref19","doi-asserted-by":"crossref","first-page":"e19","DOI":"10.1002\/mp.13839","article-title":"AAPM TG 191: clinical use of luminescent dosimeters: TLDs and OSLDs","volume":"47","author":"Kry","year":"2020","journal-title":"Med Phys"},{"key":"2025010312565532800_ref20","doi-asserted-by":"crossref","first-page":"304","DOI":"10.4103\/0973-1482.199432","article-title":"Dosimetric characterization of optically stimulated luminescence dosimeter with therapeutic photon beams for use in clinical radiotherapy measurements","volume":"13","author":"Ponmalar","year":"2017","journal-title":"J Cancer Res Ther"},{"key":"2025010312565532800_ref21","first-page":"040006","article-title":"Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation","author":"Dirgayussa","year":"2015"},{"key":"2025010312565532800_ref22","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1120\/jacmp.v13i3.3729","article-title":"Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT","volume":"13","author":"Kim","year":"2012","journal-title":"J Appl Clin Med Phys"},{"key":"2025010312565532800_ref23","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1120\/jacmp.v17i1.5799","article-title":"Commissioning an Elekta versa HD linear accelerator","volume":"17","author":"Narayanasamy","year":"2016","journal-title":"J Appl Clin Med Phys"},{"key":"2025010312565532800_ref24","doi-asserted-by":"crossref","first-page":"5986","DOI":"10.1002\/mp.14497","article-title":"Report of AAPM task group 235 Radiochromic film dosimetry: an update to TG-55","volume":"47","author":"Niroomand-Rad","year":"2020","journal-title":"Med Phys"},{"volume-title":"International Atomic Energy Agency, Absorbed Dose Determination in External Beam Radiotherapy","year":"2000","key":"2025010312565532800_ref25"},{"article-title":"Evaluation of measurement data-guide to the expression of uncertainty in measurement, International Organization for Standardization (ISO). Joint Committee for Guides in Metrology","year":"2010","author":"JCGM100","key":"2025010312565532800_ref26"},{"key":"2025010312565532800_ref27","doi-asserted-by":"crossref","first-page":"623","DOI":"10.52547\/ijrr.18.4.623","article-title":"Investigation of surface and buildup region doses for 6 MV high energy photon beams in the presence of a thermoplastic mask","volume":"18","author":"Kesen","year":"2020","journal-title":"Int J Radiat Res"},{"key":"2025010312565532800_ref28","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1016\/j.apradiso.2008.05.003","article-title":"Measurement and comparison of skin dose for prostate and head-and-neck patients treated on various IMRT delivery systems","volume":"66","author":"Roland","year":"2008","journal-title":"Appl Radiat Isot"},{"key":"2025010312565532800_ref29","doi-asserted-by":"crossref","first-page":"061501-1","DOI":"10.1118\/1.4876299","article-title":"Dosimetric effects caused by couch tops and immobilization devices: report of AAPM task group 176","volume":"41","author":"Olch","year":"2014","journal-title":"Med Phys"},{"key":"2025010312565532800_ref30","doi-asserted-by":"crossref","first-page":"573","DOI":"10.31661\/jbpe.v0i0.1083","article-title":"Skin dosimetry with EBT3 Radiochromic film in radiotherapy of parotid cancer","volume":"11","author":"Bahreyni Toossi","year":"2021","journal-title":"J Biomed Phys Eng"},{"key":"2025010312565532800_ref31","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.radonc.2013.11.002","article-title":"Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM","volume":"110","author":"Kirisits","year":"2014","journal-title":"Radiother Oncol"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/201\/1\/70\/60786370\/ncae217.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/201\/1\/70\/60786370\/ncae217.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T12:57:13Z","timestamp":1735909033000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/201\/1\/70\/7906919"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,22]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,11,22]]},"published-print":{"date-parts":[[2024,12,31]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncae217","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2025,1]]},"published":{"date-parts":[[2024,11,22]]}}}