{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:57:09Z","timestamp":1740139029123,"version":"3.37.3"},"reference-count":31,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T00:00:00Z","timestamp":1734307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,2,17]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Introduction: Bitewing examinations are used to examine the pediatric dental status. The aim of this study was to compare the image quality and radiation dose between two different X-ray systems used for pediatric bitewing imaging. Materials and Methods: Data were obtained from both pediatric in vivo bitewing studies and phantom studies. Two X-ray systems were used: Trophy CCX digital (TCCX) (Trophy Irix 70, Marne-la-Vallee, France) and Planmeca Pro X (PPX) (Planmeca, Helsinki, Finland). An Unfors dosimeter (Unfors EDD-30, Billdal, Sweden) was used to measure the skin dose. Image quality was evaluated blindly by three experienced dentists using a Likert scale of 1\u20135 based on the visual representation of the anatomical structures with emphasis on caries. Results: The highest scoring in vivo bitewing images were obtained with TCCX, but the skin dose was 36% higher (mean 3029\u00a0\u00b1\u00a0613 \u03bcGy) and 113% higher (mean 1364\u00a0\u00b1\u00a0276 \u03bcGy) with standard settings than with compared to PPX. The evaluation of image quality revealed a higher median value for all ratings of TCCX compared to PPX for both the patient and phantom studies, meaning that the images of TCCX were rated as higher quality than the images from PPX. No correlation was found between the median score and the skin dose or between the median score and the exposure times. Conclusion: A significant difference in radiation dose and image quality was found between TCCX and PPX in bitewing imaging. TCCX generally produced higher doses and better graded images, although all images were suitable for diagnosis.<\/jats:p>","DOI":"10.1093\/rpd\/ncae227","type":"journal-article","created":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T14:25:08Z","timestamp":1734359108000},"page":"113-121","source":"Crossref","is-referenced-by-count":0,"title":["Radiation dose and image quality in pediatric bitewing imaging"],"prefix":"10.1093","volume":"201","author":[{"given":"Raheis","family":"Rajalingam","sequence":"first","affiliation":[{"name":"UCL University College, Education of Radiography , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen","family":"Brage","sequence":"additional","affiliation":[{"name":"UCL University College, Education of Radiography , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]},{"name":"UCL University College, Health Sciences Research Centre , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Louise Kj\u00e6rby","family":"Nielsen","sequence":"additional","affiliation":[{"name":"UCL University College, Education of Radiography , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Freja B\u00f8gh","family":"Eriksen","sequence":"additional","affiliation":[{"name":"UCL University College, Education of Radiography , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helene Hviid","family":"J\u00f8rgensen","sequence":"additional","affiliation":[{"name":"UCL University College, Education of Radiography , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anne Sofie","family":"Mikkelsen","sequence":"additional","affiliation":[{"name":"Varde municipality , Department of Pediatric Dentistry, Lerpoetvej 50b, Varde 6800 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gitte","family":"Sch\u00f8ler","sequence":"additional","affiliation":[{"name":"Varde municipality , Department of Pediatric Dentistry, Lerpoetvej 50b, Varde 6800 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9438-7415","authenticated-orcid":false,"given":"Nejc","family":"Meki\u0161","sequence":"additional","affiliation":[{"name":"University of Ljubljana , Medical imaging and radiotherapy department, Zdravstvena pot 5, Ljubljana 100 ,","place":["Slovenia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maja","family":"Bruvo","sequence":"additional","affiliation":[{"name":"University College Absalon, Centre for Engineering and Science , Department of Radiography, Parkvej 190, Naestved 4700 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1525-5316","authenticated-orcid":false,"given":"Helle","family":"Precht","sequence":"additional","affiliation":[{"name":"UCL University College, Education of Radiography , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]},{"name":"UCL University College, Health Sciences Research Centre , Niels Bohrs All\u00e9 1, Odense M 5230 ,","place":["Denmark"]},{"name":"Lillebelt Hospital, University Hospitals of Southern Denmark, Kolding , Radiology Department, Sygehusvej 1, Kolding 6000,","place":["Denmark"]},{"name":"University of Southern Denmark, Institute of Regional Health Research , Campusvej 55, Odense M 5230 ,","place":["Denmark"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,12,16]]},"reference":[{"key":"2025021817181411300_ref1","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.3390\/ijerph13111057","article-title":"Pediatric exposures to ionizing radiation: carcinogenic considerations","volume":"13","author":"Kutanzi","year":"2016","journal-title":"Int J Environ Res Public Health"},{"key":"2025021817181411300_ref2","doi-asserted-by":"publisher","first-page":"124","DOI":"10.14740\/jocmr2796w","article-title":"Evaluation of radiation dose received by premature neonates admitted to neonatal intensive care unit","volume":"9","author":"Aramesh","year":"2017","journal-title":"Journal of clinical medicine research"},{"key":"2025021817181411300_ref3","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.icrp.2007.10.003","article-title":"The 2007 recommendations of the international commission on radiological protection","volume":"37","author":"ICRP Publication 103","year":"2007","journal-title":"Ann ICRP"},{"key":"2025021817181411300_ref4","volume-title":"Radiologic science for technologists: physics, biology, and protection","author":"Bushong","year":"2013","edition":"10. edition udg"},{"first-page":"1","article-title":"The 2007 recommendations of the international commission on radiological protection. ICRP publication 103","year":"2007","key":"2025021817181411300_ref5"},{"key":"2025021817181411300_ref6","doi-asserted-by":"crossref","DOI":"10.1201\/9781003070191","volume-title":"Radiation Protection","author":"Hallenbeck","year":"2020"},{"volume-title":"Str\u00e5lebogen: for tandfagligt personale","year":"2018","author":"Wenzel","key":"2025021817181411300_ref7"},{"key":"2025021817181411300_ref8","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1038\/sj.bdj.2017.314","article-title":"Guidelines on the timing and frequency of bitewing radiography: a systematic review","volume":"222","author":"Goodwin","year":"2017","journal-title":"Br Dent J"},{"key":"2025021817181411300_ref9","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1055\/s-0043-1777051","article-title":"Caries Etiology and preventive measures. Eur","volume":"18","author":"Meyer","year":"2024","journal-title":"J Dent"},{"key":"2025021817181411300_ref10","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1111\/j.1600-0722.1993.tb01647.x","article-title":"Radiographic screening examination: frequency, equipment, and film in general dental practice in Denmark","volume":"101","author":"Hintze","year":"1993","journal-title":"Scand J Dent Res"},{"key":"2025021817181411300_ref11","first-page":"313","volume-title":"The Reference Manual of Pediatric Dentistry","author":"American Academy of Pediatric Dentistry","year":"2024"},{"key":"2025021817181411300_ref12","doi-asserted-by":"publisher","first-page":"248","DOI":"10.4103\/1119-3077.164338","article-title":"Assessment of intraoral image artifacts related to photostimulable phosphor plates in a dentomaxillofacial radiology department","volume":"19","author":"Gulsahi","year":"2016","journal-title":"Niger J Clin Pract"},{"author":"Citiodent imaging","key":"2025021817181411300_ref13"},{"volume-title":"Planmeca Pro X: user manual","year":"2020","author":"Planmeca","key":"2025021817181411300_ref14"},{"volume-title":"Intra-oral X-ray System: IRIX 70 User manual","year":"2020","author":"Trophy","key":"2025021817181411300_ref15"},{"key":"2025021817181411300_ref16","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1007\/s40368-020-00544-8","article-title":"Outcomes of different radioprotective precautions in children undergoing dental radiography: a systematic review","volume":"21","author":"Van Acker","year":"2020","journal-title":"Eur Arch Paediatr Dent"},{"key":"2025021817181411300_ref17","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.14219\/jada.archive.2008.0339","article-title":"Patient risk related to common dental radiographic examinations: the impact of 2007 international commission on radiological protection recommendations regarding dose calculation","volume":"139","author":"Ludlow","year":"2008","journal-title":"J Am Dent Assoc"},{"year":"2018","author":"Sundhedsstyrelsen","key":"2025021817181411300_ref18"},{"key":"2025021817181411300_ref19","doi-asserted-by":"publisher","first-page":"81","DOI":"10.2298\/VSP1201081I","article-title":"Application of radiovisiography (digital radiology) in dental clinical practice","volume":"69","author":"Ilic","year":"2012","journal-title":"Vojnosanitetski pregled Military-medical and pharmaceutical review"},{"key":"2025021817181411300_ref20","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1259\/dmfr\/33467269","article-title":"Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies","volume":"41","author":"Schropp","year":"2012","journal-title":"Dentomaxillofac Radiol"},{"key":"2025021817181411300_ref21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"ICRP publication 135: diagnostic reference levels in medical imaging","volume":"46","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann ICRP"},{"author":"Huelke","key":"2025021817181411300_ref22"},{"key":"2025021817181411300_ref23","doi-asserted-by":"publisher","first-page":"S14","DOI":"10.1016\/j.radi.2019.06.006","article-title":"Radiographers\u2019 perspectives\u2019 on visual grading analysis as a scientific method to evaluate image quality","volume":"25","author":"Precht","year":"2019","journal-title":"Radiography"},{"key":"2025021817181411300_ref24","first-page":"55","article-title":"A technique for the measurement of attitudes","volume":"22","author":"Likert","year":"1932","journal-title":"Arch Psychol"},{"key":"2025021817181411300_ref25","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1037\/h0031619","article-title":"Measuring nominal scale agreement among many raters","volume":"76","author":"Fleiss","year":"1971","journal-title":"Psychol Bull"},{"year":"2017","author":"Public Health England","key":"2025021817181411300_ref26"},{"key":"2025021817181411300_ref27","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1016\/j.ejrad.2015.04.027","article-title":"Effect of staff training on radiation dose in pediatric CT","volume":"84","author":"Hojreh","year":"2015","journal-title":"Eur J Radiol"},{"key":"2025021817181411300_ref28","doi-asserted-by":"publisher","first-page":"2039","DOI":"10.1007\/s00330-011-2168-5","article-title":"An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose","volume":"21","author":"Schindera","year":"2011","journal-title":"Eur Radiol"},{"key":"2025021817181411300_ref29","doi-asserted-by":"publisher","first-page":"57","DOI":"10.12659\/PJR.892758","article-title":"Radiation safety awareness among medical staff","volume":"80","author":"Szarmach","year":"2015","journal-title":"Pol J Radiol"},{"key":"2025021817181411300_ref30","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1097\/00004424-200108000-00004","article-title":"Effect of dose levels on the diagnostic performance of a selenium-based digital chest system","volume":"36","author":"Van Heesewijk","year":"2001","journal-title":"Investig Radiol"},{"key":"2025021817181411300_ref31","doi-asserted-by":"crossref","first-page":"339","DOI":"10.2214\/ajr.185.2.01850339","article-title":"Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease","volume":"185","author":"Kroft","year":"2005","journal-title":"Am J Roentgenol"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/201\/2\/113\/61198604\/ncae227.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/201\/2\/113\/61198604\/ncae227.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,18]],"date-time":"2025-02-18T17:18:35Z","timestamp":1739899115000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/201\/2\/113\/7925300"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,16]]},"references-count":31,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,12,16]]},"published-print":{"date-parts":[[2025,2,17]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncae227","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2025,2]]},"published":{"date-parts":[[2024,12,16]]}}}