{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T12:44:27Z","timestamp":1763729067301,"version":"build-2065373602"},"reference-count":37,"publisher":"Oxford University Press (OUP)","issue":"16","license":[{"start":{"date-parts":[[2025,8,8]],"date-time":"2025-08-08T00:00:00Z","timestamp":1754611200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,10,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study evaluated radiation dose to the eye lens and the shielding efficacy of a radiation-protective eye mask (E-Mask) during repeated chest and abdomen computed tomography (CT) scans. Dose measurements were obtained using an anthropomorphic phantom and an optically stimulated luminescence dosemeter (Model TOPAZ, LANDAUER, USA). A 5-y follow-up scenario for Hodgkin lymphoma was simulated by assuming one scan per quarter, with the single-scan dose multiplied by 20 to represent four scans annually over 5-y. Despite the use of low-dose protocols based on national diagnostic reference levels issued by the Korea Disease Control and Prevention Agency, unshielded cumulative lens doses reached 363.89\u00a0mSv (right) and 424.84\u00a0mSv (left). Using an E-Mask reduced these doses to 243.96\u00a0mSv and 240.13\u00a0mSv, corresponding to reductions of 32.96% and 43.48%, respectively. These findings support the use of the E-Mask in radiosensitive populations to reduce lens exposure during long-term CT follow-up.<\/jats:p>","DOI":"10.1093\/rpd\/ncaf092","type":"journal-article","created":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T21:16:20Z","timestamp":1755033380000},"page":"1081-1089","source":"Crossref","is-referenced-by-count":1,"title":["Radiation dose to the eye lens and the shielding efficacy of a protective eye mask in patients with Hodgkin lymphoma undergoing repeated CT examinations"],"prefix":"10.1093","volume":"201","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7474-9127","authenticated-orcid":false,"given":"Do-Byung","family":"Rhee","sequence":"first","affiliation":[{"name":"Department of Radiology, Kyungpook National University Chilgok Hospital , Daegu 41404 ,","place":["South Korea"]},{"name":"Department of Biomedical Engineering, School of Medicine, Catholic University of Daegu , Daegu 42472 ,","place":["South Korea"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9686-9955","authenticated-orcid":false,"given":"Jin-Seok","family":"Yeo","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine , School of Medicine, Kyungpook National University, Kyungpook National University Chilgok Hospital, Daegu 41404, South","place":["Korea"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-7808-2604","authenticated-orcid":false,"given":"Hyo-Gi","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kyungpook National University Chilgok Hospital , Daegu 41404 ,","place":["South Korea"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-9095-8672","authenticated-orcid":false,"given":"Il-Hwan","family":"Bae","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kyungpook National University Chilgok Hospital , Daegu 41404 ,","place":["South Korea"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4368-8541","authenticated-orcid":false,"given":"Hee-June","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery , School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Daegu 41944, South","place":["Korea"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2025,8,8]]},"reference":[{"volume-title":"The 5th National Health and Medical Survey [Internet]","year":"2022","author":"Ministry of Health and Welfare, Korea","key":"2025100605111851500_ref1"},{"volume-title":"Korea leads OECD in CT scanner ownership and usage [Internet]","author":"Daily Medi","key":"2025100605111851500_ref2"},{"volume-title":"2023 Korea Medical Radiation Exposure Survey Annual Report [Internet]","year":"2024","author":"Korea Disease Control and Prevention Agency","key":"2025100605111851500_ref3"},{"key":"2025100605111851500_ref4","first-page":"1","article-title":"Radiological protection in medicine. ICRP publication 105","volume":"37","author":"International Commission on Radiological Protection","year":"2007","journal-title":"Ann ICRP"},{"key":"2025100605111851500_ref5","first-page":"1","volume-title":"Implementation guidance for occupational eye lens dose limit. NCRP Commentary No. 26","author":"National Council on Radiation Protection and Measurements","year":"2016"},{"key":"2025100605111851500_ref6","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1182\/blood-2007-07-101899","article-title":"Imaging in staging of malignant lymphoma: a systematic review","volume":"111","author":"Kwee","year":"2008","journal-title":"Blood"},{"key":"2025100605111851500_ref7","first-page":"1685","article-title":"Cumulative radiation exposure and associated cancer risk estimates in patients with lymphoma undergoing surveillance imaging","volume":"56","author":"Horowitz","year":"2015","journal-title":"Leuk Lymphoma"},{"key":"2025100605111851500_ref8","doi-asserted-by":"publisher","first-page":"1885","DOI":"10.1200\/JCO.2010.32.8427","article-title":"Long-term complications of lymphoma and its treatment","volume":"29","author":"Ng","year":"2011","journal-title":"J Clin Oncol"},{"volume-title":"2023 Annual Report on Major Surgical Statistics [Internet]","year":"2024","author":"National Health Insurance Service, Korea","key":"2025100605111851500_ref9"},{"key":"2025100605111851500_ref10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs. ICRP publication 118","volume":"41","author":"International Commission on Radiological Protection","year":"2012","journal-title":"Ann ICRP"},{"key":"2025100605111851500_ref11","first-page":"1","article-title":"Radiological protection in medicine. ICRP publication 135","volume":"46","author":"International Commission on Radiological Protection","year":"2017","journal-title":"Ann ICRP"},{"key":"2025100605111851500_ref12","first-page":"1","volume-title":"Structural Shielding Design for Medical X-Ray Imaging Facilities. NCRP Report No. 147","author":"National Council on Radiation Protection and Measurements","year":"2004"},{"key":"2025100605111851500_ref13","first-page":"1","volume-title":"Radiation Protection No. 188: Technical recommendations for monitoring individuals occupationally exposed to external radiation","author":"European Commission","year":"2017"},{"key":"2025100605111851500_ref14","first-page":"1","volume-title":"Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards. IAEA Safety Standards Series No. GSR Part 3","author":"International Atomic Energy Agency","year":"2014"},{"key":"2025100605111851500_ref15","first-page":"1","volume-title":"Radiation protection \u2013 Individual monitoring for external radiation. ISO 15382:2015","author":"International Organization for Standardization","year":"2015"},{"key":"2025100605111851500_ref16","first-page":"1","volume-title":"Radiation dose management for fluoroscopically-guided interventional medical procedures. NCRP Report No. 168","author":"National Council on Radiation Protection and Measurements","year":"2010"},{"key":"2025100605111851500_ref17","first-page":"276","article-title":"Eye lens dosimetry for workers: current issues and future needs","volume":"184","author":"Martin","year":"2019","journal-title":"Radiat Prot Dosim"},{"key":"2025100605111851500_ref18","first-page":"412","article-title":"Evaluation of eye lens dose reduction using shielding device during CT scans","volume":"73","author":"Kim","year":"2023","journal-title":"New Phys Sae Mulli"},{"key":"2025100605111851500_ref19","first-page":"1","volume-title":"TOPAZ Dosimetry System Specifications","author":"LANDAUER","year":"2022"},{"key":"2025100605111851500_ref20","first-page":"55","article-title":"Performance evaluation and calibration of Al\u2082O\u2083:C OSL dosimeters for eye lens monitoring in medical X-ray fields","volume":"190","author":"Touzani","year":"2020","journal-title":"Radiat Prot Dosim"},{"key":"2025100605111851500_ref21","first-page":"1","volume-title":"AAPM Report No. 204: Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations","author":"American Association of Physicists in Medicine","year":"2011"},{"key":"2025100605111851500_ref22","first-page":"1","volume-title":"Quality Control Standards for Medical Imaging Equipment under Medical Service Act","author":"Ministry of Health and Welfare, Korea","year":"2023"},{"key":"2025100605111851500_ref23","doi-asserted-by":"publisher","first-page":"6400","DOI":"10.1200\/JCO.2005.05.016","article-title":"State-of-the-art therapeutics: Hodgkin\u2019s lymphoma","volume":"23","author":"Connors","year":"2005","journal-title":"J Clin Oncol"},{"volume-title":"SEER Cancer Statistics Review, 1975\u20132019","author":"Howlader","key":"2025100605111851500_ref24"},{"first-page":"1","volume-title":"NCCN Clinical Practice Guidelines in Oncology: Hodgkin Lymphoma. Version 2.2025","author":"National Comprehensive Cancer Network (NCCN)","key":"2025100605111851500_ref25"},{"key":"2025100605111851500_ref26","first-page":"1","volume-title":"Computed Tomography: Fundamentals, System Technology, Image Quality, Applications","author":"Kalender","year":"2011","edition":"3rd"},{"key":"2025100605111851500_ref27","first-page":"211","article-title":"Selection of appropriate statistical tests for radiation dosimetry studies: t-test versus non-parametric alternatives","volume":"42","author":"Kim","year":"2019","journal-title":"J Radiol Sci Technol"},{"key":"2025100605111851500_ref28","first-page":"144","article-title":"Imaging utilization in hospitalized leukemia patients: a tertiary center experience","volume":"47","author":"Park","year":"2012","journal-title":"Korean J Hematol"},{"key":"2025100605111851500_ref29","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1148\/radiol.2303021726","article-title":"Strategies for CT radiation dose optimization","volume":"230","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"2025100605111851500_ref30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs \u2013 threshold doses for tissue reactions in a radiation protection context","volume":"41","author":"ICRP","year":"2012","journal-title":"Ann ICRP"},{"key":"2025100605111851500_ref31","volume-title":"Radiobiology for the Radiologist","author":"Hall","year":"2012","edition":"7th"},{"key":"2025100605111851500_ref32","first-page":"1","volume-title":"EUR 16262 EN","author":"European Commission","year":"1999"},{"key":"2025100605111851500_ref33","first-page":"1","volume-title":"The Essential Physics of Medical Imaging","author":"Bushberg","year":"2011","edition":"3rd"},{"key":"2025100605111851500_ref34","first-page":"1","volume-title":"Radiation Protection in Diagnostic and Interventional Radiology. IAEA Safety Reports Series No. 39","author":"International Atomic Energy Agency","year":"2006"},{"volume-title":"Lead Aprons, Eye Protection, and Radiation Shielding Products \u2013 Technical Specifications","year":"2022","author":"Infab Corporation","key":"2025100605111851500_ref35"},{"key":"2025100605111851500_ref36","first-page":"687","article-title":"Effectiveness of lead glasses in reducing eye lens dose in computed tomography and interventional radiology procedures","volume":"38","author":"Bilski","year":"2018","journal-title":"J Radiol Prot"},{"key":"2025100605111851500_ref37","doi-asserted-by":"publisher","first-page":"492","DOI":"10.3938\/NPSM.75.492","article-title":"Evaluation of the radiation dose reduction effect of the E-mask for lens protection and its clinical applications","volume":"75","author":"Rhee","year":"2025","journal-title":"New Physics: Sae Mulli"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/201\/16\/1081\/63990446\/ncaf092.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/201\/16\/1081\/63990446\/ncaf092.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T09:11:30Z","timestamp":1759741890000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/201\/16\/1081\/8228270"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,8]]},"references-count":37,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2025,8,8]]},"published-print":{"date-parts":[[2025,10,6]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaf092","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2025,10]]},"published":{"date-parts":[[2025,8,8]]}}}