{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T08:50:21Z","timestamp":1773391821274,"version":"3.50.1"},"reference-count":23,"publisher":"Oxford University Press (OUP)","issue":"3\u20134","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,3,13]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The use of portable computed tomography (PCT) in intensive care units (ICU) allows critically ill patients to undergo brain computed tomography examinations without the need for invasive intrahospital transportations. The aim of this study was to determine the radiation doses around a PCT unit to establish routines for radiation protection. Scattered radiation was measured around a Siemens Somatom On.site PCT system during scans of anthropomorphic and computed tomography dose index (CTDI) phantoms. The ambient dose equivalents in the ICU were estimated by summing the dose contributions from all computed tomography scan locations. Results suggest that ~15 scans per week can be performed in an ICU with six to eight patient beds without exceeding the annual effective dose of 0.1 mSv to members of the public, while also maintaining personnel exposure below 1 mSv. These findings support the feasibility of integrating PCT use into the ICU workflow as a safer alternative to intrahospital transport for neuroimaging.<\/jats:p>","DOI":"10.1093\/rpd\/ncaf121","type":"journal-article","created":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T12:19:43Z","timestamp":1759234783000},"page":"402-409","source":"Crossref","is-referenced-by-count":0,"title":["Radiation protection for people in proximity to portable computed tomography scanners in intensive care units"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-4231-1141","authenticated-orcid":false,"given":"Filip","family":"Norrman","sequence":"first","affiliation":[{"name":"Department of Radiology and Medical Physics, \u00d6rebro University Hospital, Region \u00d6rebro County , PO Box 1613, \u00d6rebro SE-701 85 ,","place":["Sweden"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9146-6396","authenticated-orcid":false,"given":"Jehangir","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Radiology and Medical Physics, \u00d6rebro University Hospital, Region \u00d6rebro County , PO Box 1613, \u00d6rebro SE-701 85 ,","place":["Sweden"]},{"name":"Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg , Gothenburg SE-413 45 ,","place":["Sweden"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,3,13]]},"reference":[{"key":"2026031302435310700_ref1","volume-title":"Computed Tomography\u2014From Photon Statistics to Modern Cone-Beam CT","author":"Buzug","year":"2010"},{"key":"2026031302435310700_ref2","volume-title":"Recommendations of the International Commission on Radiological Protection","author":"International Commission on Radiological Protection","year":"2007"},{"key":"2026031302435310700_ref3","volume-title":"Radiobiology for the Radiologist","author":"Eric","year":"2019"},{"key":"2026031302435310700_ref4","volume-title":"Radiobiology for the Radiologist","author":"Eric","year":"2019"},{"key":"2026031302435310700_ref5","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.4187\/respcare.02404","article-title":"Inter- and intra-hospital transport of the critically ill","volume":"58","author":"Blakeman","year":"2013","journal-title":"Respir Care"},{"key":"2026031302435310700_ref6","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1111\/nicc.13053","article-title":"Intrahospital transport of critically ill patients: nurse anaesthetists' and specialist ICU nurses' experiences","volume":"29","author":"Skoglund","year":"2024","journal-title":"Nurs Crit Care"},{"key":"2026031302435310700_ref7","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2342-12-34","article-title":"Brain computer tomography in critically ill patients\u2014a prospective cohort study","volume":"12","author":"Purmer","year":"2012","journal-title":"BMC Med Imaging"},{"key":"2026031302435310700_ref8","doi-asserted-by":"publisher","first-page":"1304","DOI":"10.1097\/00006123-199806000-00064","article-title":"A mobile computed tomographic scanner with intraoperative and intensive care unit applications","volume":"42","author":"Butler","year":"1998","journal-title":"Neurosurgery"},{"key":"2026031302435310700_ref9","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1111\/j.1552-6569.2011.00621.x","article-title":"Portable head computed tomography scanner\u2014technology and applications: experience with 3421 scans","volume":"22","author":"Carlson","year":"2011","journal-title":"J Neuroimaging"},{"key":"2026031302435310700_ref10","volume-title":"Str\u00e5lskyddsf\u00f6rordning (2018:506) (Sw.: Radiation Protection Regulation)","author":"The Ministry of Climate and Enterprise","year":"2018"},{"key":"2026031302435310700_ref11","volume-title":"Str\u00e5ls\u00e4kerhetsmyndighetens f\u00f6reskrifter om grundl\u00e4ggande best\u00e4mmelser f\u00f6r tillst\u00e5ndspliktig verksamhet med joniserande str\u00e5lning (SSMFS 2018:1) (Sw.: The Radiation Safety Authority\u2019s Regulations for Permit Obligated Organizations with Ionising Radiation)","author":"Swedish Radiation Safety Authority","year":"2018"},{"key":"2026031302435310700_ref12","volume-title":"Str\u00e5lskyddslag (2018:396) (Sw.: Radiation Protection Law)","author":"The Ministry of Climate and Enterprise","year":"2018"},{"key":"2026031302435310700_ref13","volume-title":"ART Phantom\u2014Alderson Radiation Therapy"},{"key":"2026031302435310700_ref14","volume-title":"Ion Chamber Survey Meter\u2014Operators Manual","year":"2013"},{"key":"2026031302435310700_ref15","first-page":"47","volume-title":"Measurement of Dose Equivalents from External Photon and Electron Radiations: ICRU Report","author":"International Commission on Radiation Units and Measurements","year":"1992"},{"key":"2026031302435310700_ref16","volume-title":"Stokastik\u2014Sannolikhetsteori och statistikteori med till\u00e4mpningar (Sw.: Stochastics\u2014Probability Theory and Statistical Theory with Applications)","author":"Alm","year":"2008"},{"key":"2026031302435310700_ref17","volume-title":"An Introduction to Error Analysis\u2014The Study of Uncertainties in Physical Measurements","author":"Taylor J","year":"1997"},{"key":"2026031302435310700_ref18","first-page":"147","volume-title":"Structural Shielding Design for Medical X-ray Imaging Facilities: NCRP Report","author":"National Council on Radiation Protection and Measurements","year":"2005"},{"key":"2026031302435310700_ref19","volume-title":"Om joniserande str\u00e5lning (Sw.: About Ionising Radiation)","author":"Swedish Radiation Safety Authority","year":"2025"},{"key":"2026031302435310700_ref20","doi-asserted-by":"publisher","DOI":"10.1186\/s13613-023-01102-3","article-title":"Critically ill patient mortality by age: long-term follow-up (CIMbA-LT)","volume":"13","author":"Gon\u00e7alves-Pereira","year":"2023","journal-title":"Ann Intensive Care"},{"key":"2026031302435310700_ref21","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1016\/j.aucc.2024.03.001","article-title":"A prolonged intensive care unit stay defines a worse long-term prognosis\u2014insights from the critically ill mortality by age (Cimba) study","volume":"37","author":"Rodrigues","year":"2024","journal-title":"Aust Crit Care"},{"key":"2026031302435310700_ref22","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s13054-024-04812-7","volume-title":"Time in ICU and Post-Intensive Care Syndrome: How Long Time is Enough? Critical Care","author":"Flaws","year":"2024"},{"key":"2026031302435310700_ref23","volume-title":"SOMATOM Onsite\u2014Instructions for Use\u2014Radiation Safety Guide","year":"2024"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/3%E2%80%934\/402\/67333263\/ncaf121.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/3%E2%80%934\/402\/67333263\/ncaf121.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T06:44:03Z","timestamp":1773384243000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/3%E2%80%934\/402\/8518634"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":23,"journal-issue":{"issue":"3\u20134","published-online":{"date-parts":[[2026,3,13]]},"published-print":{"date-parts":[[2026,3,13]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaf121","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,3]]},"published":{"date-parts":[[2026,3]]}}}