{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T15:56:55Z","timestamp":1781798215422,"version":"3.54.5"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T00:00:00Z","timestamp":1765584000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,4,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study evaluates the occupational equivalent doses to selected organs and tissues received by veterinary staff at the Veterinary Clinical Hospital of the University of Extremadura, where $\\sim $7000 diagnostic imaging procedures (X-ray and computed tomography scans) are performed annually on patients of various sizes. Experiments were conducted with dosemeters positioned to simulate typical locations of veterinary operators during radiographic procedures under clinical conditions. Canine cadavers and equine anatomical specimens were used as animal patients, and scattered radiation exposure was measured at operator-relevant sites\u2014including the hands, thorax, gonads, and eyes\u2014both with and without protective equipment. The findings confirm that, with proper radioprotection measures, doses remain well below the legal limit (500, 50 and 20 mSv y$^{-1}$ for hands, eye lens and other tissues, respectively), even in worst-case scenarios\u2014particularly during portable equine radiography exposure. However, it highlights the need for strict adherence to radiation safety protocols.<\/jats:p>","DOI":"10.1093\/rpd\/ncaf153","type":"journal-article","created":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T13:01:58Z","timestamp":1764248518000},"page":"429-440","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of occupational equivalent doses to selected organs and tissues in veterinarians from scattered radiation during X-ray and CT examinations"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7127-6763","authenticated-orcid":false,"given":"Joaqu\u00edn","family":"Jim\u00e9nez","sequence":"first","affiliation":[{"name":"Departamento de Medicina Animal, Facultad de Veterinaria, Universidad de Extremadura , Avda. Universidad, S\/N, E-10003 C\u00e1ceres ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9018-8083","authenticated-orcid":false,"given":"Jose A","family":"Corbacho","sequence":"additional","affiliation":[{"name":"Departamento de F\u00edsica Aplicada, Centro Universitario de M\u00e9rida, Universidad de Extremadura , Avda. Santa Teresa de Jornet, 38, E-06800 M\u00e9rida, Badajoz ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Escudero","sequence":"additional","affiliation":[{"name":"Departamento de Medicina Animal, Facultad de Veterinaria, Universidad de Extremadura , Avda. Universidad, S\/N, E-10003 C\u00e1ceres ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"P\u00faa","sequence":"additional","affiliation":[{"name":"Departamento de Medicina Animal, Facultad de Veterinaria, Universidad de Extremadura , Avda. Universidad, S\/N, E-10003 C\u00e1ceres ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Coral","family":"Melchor","sequence":"additional","affiliation":[{"name":"Departamento de Medicina Animal, Facultad de Veterinaria, Universidad de Extremadura , Avda. Universidad, S\/N, E-10003 C\u00e1ceres ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2025,12,13]]},"reference":[{"key":"2026061811272659800_ref1","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1093\/rpd\/ncm422","article-title":"Dose to persons assisting voluntary during X-ray examinations of large animals","volume":"128","author":"Hupe","year":"2008","journal-title":"Rad Prot Dos"},{"key":"2026061811272659800_ref2","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.radphyschem.2013.05.042","article-title":"Occupational exposure assessment in procedures of portable digital veterinary radiology for small size animals","volume":"95","author":"Canato","year":"2014","journal-title":"Radiat Phys Chem"},{"key":"2026061811272659800_ref3","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1111\/eve.12595","article-title":"Common artefacts and pitfalls in equine computed and digital radiography and how to avoid them","volume":"30","author":"Dixon","year":"2018","journal-title":"Equine Vet. Educ"},{"key":"2026061811272659800_ref4","volume-title":"International Commission on Radiological Protection.","author":"Radiological Protection in Veterinary Practice.","year":"2022"},{"key":"2026061811272659800_ref5","volume-title":"International Atomic Energy Agency","author":"Radiation Protection and Safety in Veterinary Medicine","year":"2021"},{"key":"2026061811272659800_ref6","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1111\/j.1748-5827.2012.01257.x","article-title":"Investigation into scatter radiation dose levels received by a restrainer in small animal radiography","volume":"53","author":"Barber","year":"2012","journal-title":"J Small Anim Pract"},{"key":"2026061811272659800_ref7","doi-asserted-by":"publisher","first-page":"81","DOI":"10.17221\/115\/2017-VETMED","article-title":"Restrainer exposure to scatter radiation in practical small animal radiography measured using thermoluminescent dosimeters","volume":"63","author":"Oh","year":"2018","journal-title":"Vet Med"},{"key":"2026061811272659800_ref8","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1111\/eve.12127","article-title":"Technical set-up and radiation exposure for standing computed tomography of the equine head","volume":"26","author":"Dakin","year":"2014","journal-title":"Equine Vet Educ"},{"key":"2026061811272659800_ref9","article-title":"Report 60","volume-title":"International Commission on Radiation Units and Measurements","author":"Fundamental Quantities and Units for Ionizing Radiation","year":"1998"},{"key":"2026061811272659800_ref10","article-title":"Report 47","volume-title":"International Commission on Radiation Units and Measurements","author":"Measurement of Dose Equivalents from External Photon and Electron Radiations","year":"1992"},{"key":"2026061811272659800_ref11","article-title":"The 2007 Recommendations of the International Commission on Radiological Protection","volume-title":"International Commission on Radiological Protection"},{"key":"2026061811272659800_ref12","volume-title":"Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures"},{"key":"2026061811272659800_ref13","volume-title":"Radiation Protection in Dentistry","year":"2003"},{"key":"2026061811272659800_ref14","article-title":"Radiation Protection in the Design of Radiotherapy Facilities","volume-title":"International Atomic Energy Agency"},{"key":"2026061811272659800_ref15","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1093\/rpd\/ncw305","article-title":"Implementation of ICRP 116 dose conversion coefficients for reconstructing organ dose in a radiation compensation program","volume":"173","author":"Taulbee","year":"2017","journal-title":"Rad Prot Dos"},{"key":"2026061811272659800_ref16","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1177\/0146645320911864","article-title":"Use of dose quantities in radiological protection. ICRP publication 147","volume":"50","author":"ICRP","year":"2021","journal-title":"Ann ICRP"},{"key":"2026061811272659800_ref17"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/5\/429\/65877096\/ncaf153.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/5\/429\/65877096\/ncaf153.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T15:27:36Z","timestamp":1781796456000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/5\/429\/8379495"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,13]]},"references-count":17,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,12,13]]},"published-print":{"date-parts":[[2026,4,6]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaf153","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,4]]},"published":{"date-parts":[[2025,12,13]]}}}